No.ItemUnitMin.Typ.Max.Remark
01 

Input voltage

Vac90/200110/220130/260
02 

Input power

W389
03 

Constant charge voltage

Vdc14.414.614.8
04Float voltage(for lead acid battery only)Vdc\\\
05 

Constant charge current

A192021
06 

Charge complete current

A1.41.61.88%CC
07 

Ripple voltage

mV200
08 

Efficiency

%80..Full load

Charge Curve

Eco-Worthy-20A-12V-Smart-Battery-Charger-User-Guide-Image-3

Protection Characteristics

Output Over Voltage Protection
When the charger output voltage exceeds the maximum charging voltage, the
charger enters the standby state protection. It will restore to normal working
condition automatically after troubleshooting.

Output Over Current Protection
When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. It will restore to normal working condition automatically after troubleshooting.

Short Circuit Protection
When the charger has short circuit at output, the charger enters short-circuit protection status. It will restore to normal working condition automatically after troubleshooting.

Environmental

Working Conditions

  • Ambient temperature: -5°C ~+40°C;
  • RH: 5% ~95%; Max. altitude: 2000 meter;
  • Cooling: UY series chargers use of forced air cooling system. Under dustless and ventilated conditions, the full load temperature rise not exceeding 40°C.

Storage Conditions

  • Ambient temperature: -40°C ~+70°C;
    RH:0% ~95%; Max. altitude: 20000 meter.

Reliability

No.ItemDescriptionRemark
01MTBFAverage operating life > 30000h25 °C
02Anti-vibration5mm/50Hz/600s vibration testPASS

Safety

Insulation Characteristics

 

Insulation resistant

Input to outputDC 500V 50MQ min (25°C, Humidity^70%)
Input to caseDC 500V 50MQ min (25°C, Humidity^70%)
Output to caseDC 500V 50MQ min (25°C, Humidity^70%)
 

 

Hi-Pot

Input to output1500 Vac 50Hz 1 minute <10mA
Input to case1500 Vac 50Hz 1 minute <10mA
Output to case500 Vac 50Hz 1 minute <10mA