SereneLife PSLAPU35 Air Purifier featured

SereneLife PSLAPU35 Air Purifier Manual

SERENELIFE LOGO

SereneLife PSLAPU35 Air Purifier Manual

SereneLife PSLAPU35 Air Purifier

READ AND SAVE THESE INSTRUCTIONS

WARNINGS
Failure to comply with the warnings listed below may result in electric shock or serious injury.

This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.

When using electrical appliances, basic precautions should always be followed to reduce the risk of fie, electric shock and injury to persons, including the following:

  • Readall instructions before using
  • IMPORTANT – This appliance has a polarized plug (one blade is wider than the other).To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the  If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
  • Toavoid fie or shock hazard, plug the appliance directly into a right AC electrical
  • Keepthe cord out of heavy traffic  To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters.
  • Top rotect against electrical hazards, DO NOT immerse in water or other  Do not use near water.
  • Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the
  • Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in  Be sure to pull by the plug and not the cord.
  • NEVER drop or insert any object into any
  • DO NOT run cord under
  • DO NOT cover cord with throw rugs, runners, or similar
  • DO NOT route cord under furniture or  Arrange cord away from traffic area and where it will not be tripped over.

TECHNICAL SPECIFICATIONS

  • Rated Voltage: AC 110-240V, 50Hz
  • Rated Power: 55W
  • Noise Level: 30dB (Low), 40dB (Med), 50dB (Hi)
  • UV Light: Wavelength: 254 nanometers
  • Lamp life: Approx. 20,000 hours
  • Weight: 9.25 lbs.
  • Dimensions: (L x W x H): 12.8” x 6.4” x 16.1”
  • Coverage Area: Up to 430’+ Square Feet

PRODUCT STRUCTURE

SereneLife PSLAPU35 Air Purifier fig 1

AIR CLEANING SYSTEM

Improve your indoor air quality with your new Air Cleaning System. Multiple levels of cleaning include a combination HEPA filter that captures allergens, and Activated Carbon filter to remove odors. UV-C light technology enhances germ-killing.

  • PRE-FILTER: Captures initial dust and allergen particles.
  • HEPA FILTER: Captures dust, smoke, pollen and other allergens.
  • ACTIVATED CARBON FILTER: Absorb formaldehyde, benzene and other noxious gas.
  • UV-C LIGHT
    UV-C light technology works with filters to enhance the elimination of airborne germs Titanium Dioxide is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.

OPERATING INSTRUCTIONS

BEFORE OPERATING THE AIR PURIFIER:

  1. Carefully remove your air purifier from box and bag.
  2. Select a firm, level and flat location for the air purifier.
    *For proper air flow, locate the unit at least 1 foot from any wall or furniture. *Make sure none of the grills are blocked.
  3. Plug the power cord into a right voltage AC outlet.
    IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.

PSLAPU35

OPERATING THE AIR PURIFIER

  1. “POWER/UV-C” BUTTON:SereneLife PSLAPU35 Air Purifier fig 3
    Press this button to turn on or switch off the unit.
    First press, power on, UV off.
    Second press, power on, UV on.
    Third press, power on, UV off.
    Fourth press, power off.
  2. “SPEED” BUTTON:SereneLife PSLAPU35 Air Purifier fig 4
    The fan speed of the unit can be adjusted when the unit is in operation (L/I M/II H/III). Each time that you press on the (SPEED) button, the speed is adjusted from L (low) to M (medium) to H (high).
  3. “TIMER” BUTTON:SereneLife PSLAPU35 Air Purifier fig 5
    1. By pressing this button, the purifier can be timed to operate for intervals of 2 hours, 4 hours and 8 hours, stopping automatically when the selected operating time has elapsed.
    2. Press this button (Timer) to select the required operating time. A warning light automatically indicates the remaining operating time.
    3. To select the continuous operating mode, press the button repeatedly until there are no more indicator lights lit up.

Important note: When the unit is not in use, switch it off and unplug it.

INSTALLING & REMOVING

FILTERS
The POWER light will flashing continuously in GREEN indicating that it is time to replace the filter. Replace the filter according to the directions then press the POWER/UV-C button and hold for 5 seconds to restart the system. The light will stop flashing.

SereneLife PSLAPU35 Air Purifier fig 6

  1. Open the front cover from the top.
  2. Remove the combination filter by pull the two strips.
  3. Insert new Combination Filter into the unit. Consult the strips on the filter for correct installation direction.
  4. Reattach the extra Pre-filter to the Combination Filter.
  5. Reattach the Front Cover of the unit and securely latch into place.
  6. Press and hold POWER/UV-C Button for 5 seconds to reset Filter Change Indicator.

CLEANING & MAINTAINING

THE COMBINATION FILTER

The air purifier should be cleaned at least once every month and the outer Pre-/Activated Carbon Filter attached to the HEPA Filter should be cleaned every month. More frequent cleaning may be required depending on environmental conditions.

PRE-/ACTIVATED CARBON FILTER
Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt.

SereneLife PSLAPU35 Air Purifier fig 7

NOTE:

  • Only the Extra Pre-filter is washable.
  • The Combination Filter is one filter system. The multiple layers include: the Pre-filter, Activated Carbon Filter and HEPA Filter.
AIR PURIFIER

Use a clean, dry, soft cloth to wipe the external surface of the unit.

NOTE: Do NOT stick any foreign objects or your fingers inside of the unit.
CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents.

MINI TROUBLESHOOTING GUIDE

Before carrying out any of the following service checks, unplug the unit from the mains.

Insufficient air flowCheck that the filters are clean

Check for any obstructions in the air inlet and outlet

Unit will not startCheck the power supply and electric fuses.

Check that the Front Cover is latched firmly in place.

Excessive noiseCheck for any foreign objects in contact with the fan. The filter may be clogged and ready for replacement. The foam sealing gaskets have been installed incorrectly.

Uneven positioning.

 