WARNINGS
- CAUTION: To reduce the risk of severe burns, keep this product out of the reach of children and pets.
- Caution is necessary when any appliance is used by or near children or people with disabilities and whenever the appliance is left operating unattended.
- Disassembly, repair, or remodeling by an unauthorized person may result in serious harm and will void the manufactures warranty.
- The product is for indoor use only.
- Always place this humidifier on a firm, flat & level surface. This humidifier may not work properly on an uneven surface.
- Do not place this product on cloth, carpet, or an absorbent surface. This may block the air inlet.
- This product releases mist. Do not place this humidifier directly on wood furniture, flooring, or any surfaces that could be damaged by water. The manufacturer does not accept any liability for damage in the case of the unit being placed incorrectly.
- Do not use it if the plug is damaged or loose.
- Before filling or cleaning the unit, make sure it is unplugged.
- Once the humidifier has been plugged in, do not tilt or move the unit.
- Do not handle the plug with wet hands.
- Do not excessively bend, twist, pull, or damage the power cord.
- Avoid placing this product where the humidity spout is pointed directly at an object or person.
- Do not inhale the mist/vapor expelled from the product or drink water from the tank.
- Do not fill the water tank with hot or boiling water.
- Do not use this product in direct sunlight or near a heat source such as a stove, heater, or radiator.
PARTS
FUNCTION HIGHLIGHTS
This 3-in-1 product provides the benefits of a Himalayan salt lamp and ultrasonic humidifier with an aromatherapy tray for essential oils.
DIRECTIONS FOR USE
Select a firm, level, flat location – at least six inches (15 cm) from any wall or object for proper airflow. Take care when carrying, remove or secure the salt crystal tray to prevent it from sliding out. Place the humidifier on a water-resistant surface, as water can damage furniture and some flooring. Do not place the unit directly on the carpet, towels, blankets, or other absorbent surfaces. Guardian Technologies will not accept responsibility for damage caused by water spillage. Filling – Make sure the unit is unplugged.
- Separate the tank from the base of the unit.
- Open the tank lid, turning it to the left.
- Pour cool, clean water directly into the tank. Do not pour anything but water into the tank.
- Close the tank lid, turning it to the right. FIRMLY secure the cap after filling the tank.
- Replace the mist nozzle and return the tank to the base of the unit.
- Remove the salt crystal tray.
- Carefully remove the wrapping. Arrange salt crystals to be distributed evenly in the tray.
- Add Essential Oil: slide the aroma tray out from the back of the salt tray. Add a few drops of your favorite essential oil to the pad in the tray (oil not included). WARNING: DO NOT add oils or other additives directly into the water tank. DO NOT add oils directly to the salt crystals. Add only to the pad in the tray.
- Return the salt tray to the humidifier so that it fits firmly in the unit. If it doesn’t fit rearrange the crystals for a better fit.
- Plug the cord into the back of the humidifier and then plug the unit into the wall outlet.
NOTE: The salt lamp can be operated with or without the humidifier.
OPERATING INSTRUCTIONS
Timer
Press the timer button to select 2, 4, or 8 hours. The humidifier will turn off after that time. Any lights on the salt lamp will need to be turned off manually
Power
Press the power button to turn the humidifier on and again to turn it off.
Light
Select the preferred light level. P
Mist
Select low or high mist by pressing the control button once for high and twice for low. Default speed: I speed (Low) 1st press: II speed (High) 2nd press: I speed (Low).
CLEANING
Always unplug the unit before servicing it in any way.
GENERAL CLEANING
- Remove the salt tray and dust off the salt crystals with a clean dry cloth. Do not wash or clean salt crystals with water or liquid detergents. If the salt crystal becomes moist, gently pat down the crystal surface with a dry cleaning cloth.
- Empty water tank. Remove the mist spout and clean with fresh water and a light brush (bottle cleaning brush is recommended).
- Wipe the outer surface of the unit with a soft, damp cloth if needed. If you notice an accumulation of water during usage, reduce humidity and dry the outer surface with a cloth.
DESCALING
- Depending on usage and water type, cleaning to remove scale may be required weekly or every other week to optimize unit performance.
- If you live in a hard water area, we recommend the use of distilled water for your humidifier. This will help reduce the precipitation of minerals or ‘white dust’.
- Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.
ULTRASONIC DISK
- Unplug the unit.
- Remove the tank and empty all water from the unit base and tank.
- Locate the ultrasonic disk on the inside center of the base unit.
- Use ONLY the enclosed cleaning brush to gently clean the disk and remove build-up and deposits. Do not scrub or scrape the ultrasonic disk.
If scale becomes difficult to remove with a brush:
- Fill the Base with a mixture of 1 tsp. white vinegar and 1 tsp. water.
- Let the solution stand for 5 minutes.
- With the vinegar in the Base, clean all interior surfaces with a soft cloth or brush to help remove scale.
- Also, check the mist nozzle and mist tube in the water tank. Clean as needed.
- Rinse the Base thoroughly with water to remove the scale and vinegar solution.
IMPORTANT:
IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.
TROUBLESHOOTING GUIDE
PROBLEM | SOLUTION |
Water vapor and humidity are not produced. | Power Plug: Unplug and then try again. Power Failure: When the power is returned, try again. Tank Installation: Make sure the tank is correctly attached. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. |
Air blows but water vapor is not produced. | Excessive Water: Remove a certain amount of water from the tank. The desired humidity is lower than the current temperature: Increase the desired humidity. Detergent residue and/or oil ingredients from cosmetics, etc. may be in the tank; wash out the tank and try again. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. If you use hard water, replace it with softer water. |
The humidity level is low. | The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. Damage on the ultrasonic disk: Contact Customer Service |
The humidity has a bad smell. | Poor maintenance or dirty water: Clean the product thoroughly, and fill it with fresh water. |
White dust is forming on nearby furniture. | Hard water may deposit a certain amount of dust. |
The unit has stopped working. | No or low water. Unplug the unit and refill the water tank. |
The unit shuts off unexpectedly or does not operate. | Check that the safety device is triggered. Call Customer Service. |
Water is accumulating outside of the unit or the area surrounding the unit. | Saturation of humidity. Lower mist control setting. The unit is not level and water is accumulating. Unplug and place on a level surface. Point spray away from objects. Raise the unit on a water-resistant level surface 2-3 feet off of the floor. |
Water dripping when refilling. | Water remaining on the bottom of the tank. Make sure the tank cap is secured tightly. |
Increased noise level. | The unit must be placed on a flat, level, hard surface. Make sure it is NOT placed on a soft or absorbent surface. |
Cannot smell the aroma scent. | Add a few more drops of oil to the aroma pad or replace the aroma pad with a new one. |
LIMITED WARRANTY
To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. Save your original sales receipt to validate the start of the warranty period. If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge.
The complete machine must be delivered pre-paid to any authorized Guardian Technologies LLC warranty service center. Please include complete information on the problem, the day of purchase, a copy of the original sales receipt, and your name, address, and telephone number. If you are not near a warranty station, call the factory for assistance in the US and Canada at 1-866-603-5900. Use only genuine Guardian Technologies replacement parts. The warranty does not include unusual wear, damage resulting from an accident, or unreasonable use of the product.