IMPORTANT SAFETY INSTRUCTIONS

DANGER
TO REDUCE THE RISK OF ELECTRIC SHOCK:

  • Always unplug the appliance from the electrical outlet immediately after using it and before cleaning.
  • DO NOT reach for an appliance that has fallen into the water. Unplug it immediately.
  • NEVER use pins or other metallic fasteners with this appliance.

WARNING

  • An appliance should never be left unattended when plugged in. Unplug from the outlet when not in use, and before putting on or taking off parts or attachments.
  • Close supervision is necessary when this appliance is used by, on, or near children, invalids, or disabled persons.
  • Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically, any attachments not provided with the unit.
  • NEVER operate this appliance if it has a damaged cord or plug if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a HoMedics Service Center for examination and repair.
  • Keep the cord away from heated surfaces.
  • NEVER drop or insert any object into any opening.
  • DO NOT operate where aerosol (spray) products are being used or where oxygen is being administered.
SAVE THESE INSTRUCTIONS

CAUTION
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.

  • NOT recommended for use by diabetics.
  • NEVER leave the unit unattended, especially if children are present.
  • NEVER cover the unit when it is in operation.
  • DO NOT use this product for more than 15 minutes at a time.
  • Extensive use could lead to the product’s excessive heating and shorter life. Should this occur, discontinue use and allow the unit to cool before operating.
  • NEVER use this product directly on swollen or inflamed areas or skin eruptions.
  • DO NOT use this product as a substitute for medical attention.
  • DO NOT use this product before bed. The massager has a stimulating effect and can delay sleep.
  • NEVER use this product while in bed.
  • This product should NEVER be used by any individual suffering from any physical ailment that would limit the user’s capacity to operate the controls.

Assembly and Instructions for Use

  1. Unpack the product. Wipe off the dust with a damp cloth. (Fig 1)
    Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 1
  2. Assemble the fountain stand: NOTE: For easy reference, each leg is labeled.
    • a. Place the Bottom Ring on a flat surface allowing the ring to slightly hang over for easy alignment and tightening of screws as shown in Figure 2. Align the holes of the Bottom Ring with the holes on the Bottom Legs and PARTIALLY secure by tightening the screws using the screwdriver provided. Repeat until all three of the Bottom Legs are partially secure. (Fig 2) NOTE: DO NOT tighten completely at this point.
      Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 2
    • b. Insert the Bottom Legs into the Leg Holder and adjust so they sit evenly. Now, completely tighten the three screws in the Leg Holder and the three screws in the Bottom Ring. (Fig 3) NOTE: Before inserting legs, you may need to unscrew the screws from the Leg Holder to allow for the legs to slide into the holder properly.
      Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 3
    • c. Insert the Upper Legs into the other end of the Leg Holder. NOTE: The Bottom Leg with the cord clip should be positioned on the same side of the Leg Holder as the Upper Leg with the cord clip. DO NOT tighten screws in Leg Holder at this point. (Fig 4)
      Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 4
      Conitnued
  3. Assemble the fountain top:
    • a. Familiarize yourself with the pump. The switch located at the front of the pump controls the pump speed. The speed is indicated by a plus (+) and minus (-) sign. To increase the speed, move the switch slowly downward in the direction of the plus sign. You will hear a click as the switch moves to each speed level. At its highest speed level, the switch will cease to move any further. To decrease the pump speed, move the switch upward toward the minus sign. Similarly, at its lowest speed, the switch will cease to move any further (Fig 7). NOTE: It is recommended the pump be set at its highest speed during assembly and later adjusted to a lower setting if desired. Be sure to unplug the pump before adjusting the speed setting.
      Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 5
      Attention: In order to get the best results, please operate the pump completely submerged. Keep the water level above the minimum water level ALL THE TIME.
      Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 6
    • b. Insert the rubber end of the waterproof lights into the light clips located inside the base while keeping the light cords in the position shown in Figure 8. (Fig 8) Slight twisting may help to push the rubber end through the clip more easily. NOTE: Be gentle with the bulb cover since it is made of glass.
      Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 7

      Continued

    • c. Insert the small end of the connector into the pump. (Fig 9)
    • d. Insert LED light into the water inlet attached to the top of the fountain. (Fig 10)
    • e. Insert the large end of the connector into the water inlet attached to the top of the fountain. (Fig 10) NOTE: You must first slide the LED light through the water inlet.
    • f. Place the fountain top; with a pump attached, on the fountain base. (Fig 11)
      Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 8
  4. Set the assembled fountain top onto the metal stand. Align the cord so it runs down the Upper and Lower Legs that contain the cord clips. NOTE: You may need to carefully bend open the cord clips to allow room for the cord to be inserted. Place the cord in clips to minimize the appearance. (Fig 12)
    Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 9
  5. 5. Fill the base with 50 oz. of clean water. Add enough water so that the top of the pump is completely submerged. (Fig 13)
  6. Attach the A/C adaptor jack to the base power cord. DO NOT plug into the outlet at this time. (Fig 1)
  7. Set the fountain on a level, waterproof surface.
    Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 10
  8. Plug the cord into a 120V household outlet. The switch located on the power cord controls the fountain. If the pump doesn’t operate, rotate the in-line switch once to turn “on” and once more to turn “off”. Monthly maintenance will add to your pump’s life. NOTE: Ensure that the electrical cord loops below the electrical outlet to form a ‘Drip Loop’ (Fig 14). This will prevent water from running down the cord into the electrical outlet.
    Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 11

Maintenance

  • To clean the pump: Unplug from the electrical outlet. Remove it from the base of the fountain. Use a small brush or stream of water to remove any debris (Fig 15).
  • To keep the water clean: Periodically change the water and clean the product according to the water condition. Keeping the water clean prevents the water from becoming sticky and forming micro-organisms. We recommend distilled water to prevent mineral buildup.
  • To clean off hard water deposits on the base: Soak the container in a mixture of vinegar and water to clean and remove any mineral build-up.
  • Keeping the water at an optimum level: Add water periodically to keep the water level at an optimum level to avoid shortening the life of the pump. NOTE: Never let the pump run dry, as this will shorten the life of the pump.
  • Fountain Storage Unplug the fountain from the electrical outlet, empty the water and store the fountain in a dry, cool place.
  • Changing Light Bulb First, unplug the fountain and let the bulb cool down. Remove the bulb cover by holding the glass bulb cover in a dry hand and rubber neck with the other hand. Slowly pull apart. Slight twisting may help to loosen. Be gentle with the bulb cover since it is glass. Never pull on the cord. Next, pull the bulb straight out and replace it with a new bulb, inserting prongs into the holes. Replace bulb cover securely.

Homedics Illuminated Floor Stand Relaxation Fountain Manual fig 12

Troubleshooting

  • If the pump fails to operate, check the following: Check the circuit breaker, or try a different outlet to make sure the pump is getting electrical power. NOTE: Always disconnect from the electrical outlet before handling the pump.
  • If the pump gurgles, spews, or “burps”: Check the water level to make sure the pump has enough water to function.
  • Obtaining a desired water level: Check the water level daily during the first week to measure the rate of evaporation; refill with water as needed.
  • If water is splashing outside the fountain: Adjust the flow control valve to a lower setting on the pump.

Limited Year Warranty

HoMedics sells its products with the intent that they are free of defects in manufacture and workmanship for a period of one year from the date of original purchase, except as noted below. HoMedics warrants that its products will be free of defects in material and workmanship under normal use and service. This warranty extends only to consumers and does not extend to Retailers. To obtain warranty service on your HoMedics product, contact a consumer relations representative for assistance.

Please make sure to have the model number of the product available. HoMedics does not authorize anyone, including, but not limited to, Retailers, the subsequent consumer purchaser of the product from a Retailer, or remote purchasers, to obligate HoMedics in any way beyond the terms set forth herein. This warranty does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/power supply;

loss of power; dropped product; malfunction or damage of an operating part from a failure to provide manufacturer’s recommended maintenance; transportation damage; theft; neglect; vandalism; or environmental conditions; loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever that are beyond the control of HoMedics.