Ozeri BP6T Blood Pressure Monitor User Manual featured img

Ozeri BP6T Blood Pressure Monitor User Manual

Ozeri-Logo

Ozeri BP6T Blood Pressure Monitor User Manual

Ozeri BP6T Blood Pressure Monitor User Manual prduct img

Thank you for purchasing this Ozeri Blood Pressure Monitor. Please read this manual thoroughly before first use, and keep this manual handy for future reference.

INTRODUCTION
Thank you for purchasing the Ozeri BP6T Fully Automatic Blood Pressure Monitor. This device uses the oscillometric method of blood pressure measurement which detects the movement of blood through your brachial artery and converts your blood pressure into a digital reading. The unit is simple to use because no stethoscope is needed while using an oscillometric monitor. This device automatically stores 399 sets of 3 measurement values with date and time data for 3 users (1197 measurements total). You can access the stored data simply by pressing the MEM button.

The BP6T Monitor includes the following items:

  • Monitor
  • Cuff
  • Instruction manual printed in English
  • Carrying bag
  • Built-in rechargeable battery

IMPORTANT SAFETY INFORMATION

To ensure the correct use of this product, basic safety measures should always be followed. Read all information in the instruction manual and any other literature included in the box before using this device, and observe all Warnings and Cautions.

Warnings
The following are warnings of potentially hazardous situations which, if not avoided, could result in death or serious injury:

  • DO NOT confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pressure. Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
  • Consult your physician before measuring blood pressure, especially if you have any of the following conditions: Hypertension, Diabetes, Arteriosclerosis, Kidney or Vascular Disease, or any conditions affecting circulation.
  • DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.
  • The monitor is not intended to be a diagnostic device, for indoor use only.
  • This device is intended for use in measuring blood pressure and heart rates for adults only. Do not use it on infants or persons who cannot express their intentions.
  • Do not use this device if pregnant. This device is contraindicated in women who are or may be pregnant. Consult a physician instead.
  • This unit is not suitable for continuous monitoring during medical emergencies or operations.
Precautions

The following are Precautions for potentially hazardous situations which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property:

  • Read all of the information in the instruction manual and any other literature in the box before operating the unit.
  • Dispose of the device, components, and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
  • Use only Ozeri-authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
  • Operate this device only as it is intended. Do not use this device for any other purpose.
  • Do not use a cellular phone near this device. Cell phones may inhibit the accuracy of this device.
  • Do not disassemble or attempt to repair this device or any of its components. Doing so will void the warranty.
  • Do not use this device where flammable gases (such as anesthetic gas, oxygen, or hydrogen) or flammable liquids (such as alcohol) are present.

HEALTH AND BLOOD PRESSURE VALUES

What is the standard blood pressure classification? This device refers to a blood pressure classification published by the American Heart Association (AHA). The American Heart Association guidelines for the upper limit of Normal Blood Pressure are 135 mmHg for Systolic and 85 mmHg for Diastolic.

The following is a 1999 blood pressure classification chart published by the World Health Organization (WHO) and the International Society of Hypertension (ISH):

Ozeri BP6T Blood Pressure Monitor User Manual fig 1

SUGGESTIONS BEFORE MEASURING
  1. Rest for at least 5-10 minutes before taking your blood pressure.
  2. Avoid eating, smoking, exercising, bathing, and drinking (especially alcohol, caffeine, or tea) for at least 20-30 minutes before taking a measurement, and avoid talking while measuring your blood pressure.
  3. Make sure the wrist cuff is at heart level.
  4. Stress raises blood pressure. Try to keep calm before and during the measurement process.
  5. Avoid a very cold environment.
  6. Use the bathroom before taking measurements.
  7. Avoid excessive talking and hand movement.
  8. Wait at least 20 min after taking a bath or shower.
  9. Wait 2-3 minutes before retaking your blood pressure measurement.
  10. Keep the records for your physician and refer to your physician for guidance.

DEVICE COMPONENTS & CONTROL BUTTON DESCRIPTIONS

Ozeri BP6T Blood Pressure Monitor User Manual fig 2

Included:

  1. Blood Pressure Monitor (BP6T)
  2. USB Cable and AC Adaptor (INPUT: 100-240VAC 50/60Hz 0.3A Max OUTPUT:5V 1000mA)
  3. User Manual
  4. Storage Pouch

CHARGING YOUR DEVICE

  1. The BP6T blood pressure monitor uses a built-in rechargeable lithium-ion battery, with a capacity of 420 mAh.
  2. Please use the AC adaptor and USB cable to charge the battery, as illustrated in the following picture:

Ozeri BP6T Blood Pressure Monitor User Manual fig 3

CAUTION

  1. The battery of BP6T has a built-in rechargeable lithium-ion battery. Please do not disassemble. Only an authorized technician may replace it.
  2. The unit may recharge up to 300 times under normal usage. If the battery does not charge and the blood pressure monitor cannot be used normally, please contact an authorized technician. With a full charge, the unit can be used to measured three times a day for about 25 days.
  3. Store the blood pressure monitor in a cool and dry place, and avoid storing it near a heat source as it may cause the battery to explode.
  4. Only use the included AC Adapter to charge the unit. You will not be able to use the blood pressure monitor while it is charging.
  5. During the process of charging, the blood pressure monitor will display the charging icon shown at the right. When charging is finished please unplug before using.
  6. Do not use this device while it is charging.

MEASURING YOUR BLOOD PRESSURE

Starting a Measurement

  1. After correctly positioning the cuff, press the START/STOP button to turn on the device. The user icon will blink. Press “MEM” to select either User 1, 2, or 3.
    Ozeri BP6T Blood Pressure Monitor User Manual fig 4
  2. When the desired User ID blinks, press the START/STOP button again to confirm the User ID. The device will then display 0 on the LCD, and initiate a measurement for the selected user.
    Ozeri BP6T Blood Pressure Monitor User Manual fig 5
  3. Press the START/STOP button to turn off the device. The device will also turn off automatically after 1 minute of inactivity.
Important Instructions:
  • Ensure that you are not eating, talking, laughing, or smoking for at least 5 minutes before measurement.
  • Do not talk, read, eat, or watch television during measurement. Try your best to relax and avoid distractions.
  • Stimulants such as caffeine and certain medicines can affect your blood pressure. Taking your blood pressure at the same time every day in a relaxed setting will provide a better picture of your blood pressure over time.
  • Using your blood pressure monitor’s Average function is recommended as individual results may vary based on other factors, such as stress, exercise, smoking, ambient temperature, and a recent meal resulting in a full stomach and/or bladder.
  • Taking your blood pressure at home and then at your Doctor’s office can sometimes lead to different results, due to the heightened anxiety sometimes experienced when visiting the Doctor.
  • Ensure that your arm/wrist and heart are level.
  • Taking repeated readings in a rapid fashion can lead to inaccurate measurements. Allow for a few minutes to pass before the next reading, taking care to remain relaxed and calm.
  • Always sit upright while taking a measurement and rest your elbow on a flat surface. Do not cross your legs.
  • Ensure that thick clothing is removed when taking a measurement.
  • Ensure that the wrist cuff is ¼” to ½” away from the bottom of your palm.
  • Ensure that the wrist cuff is fitted so as to allow one finger to fit in between your wrist and the cuff.
  • Do not place cellular phones near the blood pressure monitor.

IRREGULAR HEARTBEAT?

If an irregular rhythm is detected more than twice during measurement, the irregular heartbeat symbol with three hearts will appear on the display along with the measurement results.

Ozeri BP6T Blood Pressure Monitor User Manual fig 6

Note:
The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular heartbeat was detected during measurement. Usually, this is NOT a cause for concern. However, if the symbol appears often, we recommend you seek medical advice. Please note that the device does not replace a cardiac examination, but serves to detect pulse irregularities at an early stage. Do not use this device as a substitute for proper medical diagnosis and check-ups by your physician.

WHAT IS ARRHYTHMIA?

A heartbeat is stimulated by electrical signals that cause the heart to contract. Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in the bio-electrical system that drives the heartbeat. Typical symptoms are skipped heartbeats, premature contraction, and an abnormally rapid (tachycardia) or slow (bradycardia) pulse. This can be caused by heart disease, aging, physical predisposition, stress, lack of sleep, fatigue, etc. The appearance of an irregular heartbeat symbol does indicate arrhythmia. Arrhythmia and other heart conditions can only be properly diagnosed by a doctor through a medical examination.

TROUBLESHOOTING THE UNIT

The following table includes a list of error messages and the possible causes and solutions for problems you may encounter with your blood pressure monitor. If the product is not operating as you think it should, please check here before arranging for servicing.

PROBLEMINDICATIONCAUSEREMEDY
 

No power

 

Display is dim or will not light up.

 

Batteries are dead.

 

Charge the device.

Low battery chargeLow battery charge symbol on screenBattery charge is too low.Charge the device.
 

 

 

 

 

 

 

Error massage

E 1The cuff is not secured properly.Refasten the cuff

and then measure again.

E 2The cuff over inflated.Refasten the cuff and then measure again.
E 3The cuff is too tight due to over-inflation.Relax for a moment

and then measure again.

E 10 or E 11The monitor detected motion while measuring.Movement can affect the measurement. Relax for a moment and then measure again.
E 20The monitor did not detect a pulse signal.Refasten the cuff, taking care not to overtighten. Then measure again.
E 21Measurement error.Relax for a moment and then measure again.
EexxA calibration error occurred.Relax and retake the measurement. If the problem persists, contact support@ozeri.com for further assistance. Refer to the warranty for contact information and return instructions.

MAINTENANCE

In order to get the best performance and maximize the life of your unit please review the following tips:.

Ozeri BP6T Blood Pressure Monitor User Manual fig 7

SPECIFICATIONS

PROBLEMINDICATIONCAUSEREMEDY
 

No power

 

Display is dim or will not light up.

 

Batteries are dead.

 

Charge the device.

Low battery chargeLow battery charge symbol on screenBattery charge is too low.Charge the device.
 

 

 

 

 

 

 

Error massage

E 1The cuff is not secured properly.Refasten the cuff

and then measure again.

E 2The cuff over inflated.Refasten the cuff and then measure again.
E 3The cuff is too tight due to over-inflation.Relax for a moment

and then measure again.

E 10 or E 11The monitor detected motion while measuring.Movement can affect the measurement. Relax for a moment and then measure again.
E 20The monitor did not detect a pulse signal.Refasten the cuff, taking care not to overtighten. Then measure again.
E 21Measurement error.Relax for a moment and then measure again.
EexxA calibration error occurred.Relax and retake the measurement. If the problem persists, contact support@ozeri.com for further assistance. Refer to the warranty for contact information and return instructions.

ACCESSORIES

Ozeri BP6T Blood Pressure Monitor User Manual fig 8

Contact Information
Distributed by Ozeri Customer service: 1-877-299-1296 or Email: support@ozeri.com (OzeriTM and its subsidiaries assume no liability for damage caused by the use of the Ozeri Blood Pressure Monitor other.

FCC Statement (USA only)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Compiled Standards List
USAEU
Risk ManagementISO 14971:2007EN/ISO 14971:2012
LabelingEN 980:2008EN 15223-1:2012
User ManualEN 1041:2008EN 1041:2008
General Requirements for SafetyIEC 60601-1:2005EN 60601-1:2006/AC2010 EN 60601-1-11:2010
Non-invasive Sphygmomanometers General RequirementsASSI/AAMI SP10:2002/A1:2003/A2:2006/(R)2008EN 1060-1:1995+A2:2009 EN 1060-3:1997+A2:2009 EN 1060-4:2004
Electromagnetic CompatibilityEN 60601-1-2:2007EN 60601-1-2:2007/AC:2010
Software LifetimeEN 62304:2006/AC:2008EN 62304:2006/AC:2008

WARRANTY INFORMATION

Should your blood pressure monitor and/or wrist cuff appear defective within the applicable period from the date of purchase, return the defective unit, freight prepaid along with an explanation of the claim to Ozeri. Please pack carefully to avoid damage in transit. This warranty extends only to personal use and does not extend to any product that has been used for commercial use, or use which is not intended.

This warranty is not transferable. Ozeri is not responsible in any way for damages, losses, or inconveniences caused by equipment failure caused by user negligence, abuse, or use not in accordance with the “User Guide” or any additional safety, use, or warnings included in the product materials.

  • Improper or inadequate maintenance. use.
  • Damage in return transit.
  • Unsupervised use by children under 18 years of age
  1. Ozeri Customer Service
  2. Customer service: 1-877-299-1296 (USA)
  3. Email: support@ozeri.com

REFERENCE LINK

https://ozeri.com/bath-and-personal-care/ozeri-blood-pressure-monitors

DOWNLOAD LINK

Ozeri BP6T Blood Pressure Monitor User Manual

Leave a Reply