Operation

Ritetemp Operation 8022C Thermostat Installation User Manual fig 1

Statement of use: The GPMG8022c can be used with most 24-volt gas, oil, or electric heating and air conditioning systems, single-stage heat pumps, or gas millivolt heating systems. It cannot be used with 120-volt heating systems or multistage heat pumps.

Set Clock

Set day of the week –

Ritetemp Operation 8022C Thermostat Installation User Manual fig 3

  • Press SET CLOCK once to set the day of the week. The day of the week display flashes. (Initially SU for Sunday)
  • PressRitetemp Operation 8022C Thermostat Installation User Manual fig 2
  • Press and hold to set the time in the fast mode.
Auto-run

Ritetemp Operation 8022C Thermostat Installation User Manual fig 4

This Thermostat comes preprogrammed with an Energy-StarTM-approved program. This program is recommended by the EPA for energy efficiency. We strongly recommend that you Auto-Run this program for one week, and see if it works for you. If it does not fit your needs you can always input a custom program.

  • To Auto-Run the Energy-StarTM program, select HEAT or COOL with the mode switch. The unit is now running the Energy-StarTM program.
  • The clock and the ambient temperature are displayed on the right. They alternate every 2 seconds. One of the TIME SLOT icons P1/P2/P3/P4 comes on, this indicates the TIME SLOT active in the Energy-StarTm program.
  • The programmed temperature is shown on the left. For program details refer to the Energy-StarTM program chart below.

Ritetemp Operation 8022C Thermostat Installation User Manual fig 5

Program

NOTE: 60 Second During programming, if a button is not pushed within 60 seconds, the unit will go out of the set mode. Everything you have input in this programming will automatically be saved.

Ritetemp Operation 8022C Thermostat Installation User Manual fig 6

  • Select HEAT with the HEAT/Cool MODE switch.
  • Select the day you want to program: Press the PROGRAM to enter programming mode. The PROGRAM FOR icon will come on. The day icon will show SU (Sunday). PressRitetemp Operation 8022C Thermostat Installation User Manual fig 8again to advance the day selection.
  • Select the TIME SLOT you want to program: To change the TIME SLOT (P1, P2, P3, P4) press the Ritetemp Operation 8022C Thermostat Installation User Manual fig 7button. The display will cycle through the time periods in sequence.  Select P1.
  • Select the desired temperature for that TIME SLOT: To change the temperature for that TIME SLOT press the TEMP UP / TEMP DOWN buttons.
  • Select the time of day you want that TIME SLOT to represent: To set the time when P1 will begin, press the buttons
  • Select the next TIME SLOT and program temp and time: Press Ritetemp Operation 8022C Thermostat Installation User Manual fig 7>, and the display will show P2, for Period 2. Repeat setting temp and time. Select the remaining TIME SLOTs, P3 and P4. Program their temp and time info.
  • Repeat the above procedures for each day of the week. Push the DAY> button to cycle through the days.
  • To COPY the program of the current day to another day, press COPY program once. COPY will be displayed on the LCD. The day icon for the source day will go solid and the day icon for the destination day will flash. Use Ritetemp Operation 8022C Thermostat Installation User Manual fig 8button to select the destination day. Press COPY again to confirm the copy. If you decide you don’t want to copy, press HOME to exit.
  • To program an alternate or “Special Day” program, that you can access at any time, press PRO until PROGRAM FOR for SDP DAY is displayed. Repeat the procedure above to program temp settings for the Special Day.
  • When finished with your custom program, either wait 60 sec or press HOME to save and run your program.
  • To program for cooling, select COOL with the Heat/Cool MODE switch and repeat the above procedure.
  • To REVIEW the program you have entered: Press PROGRAM once to enter programming mode. Then press FILTER/REVIEW once. The display will cycle through the programmed times and temps, showing each program for 12 seconds. Starting from Sunday; P1 and ending on Saturday; P4. The programmed temperature is shown on the left of the LCD, and the programmed time, day, and time slot are shown on the right and the right top of the LCD respectively.
  • Press HOME to leave program REVIEW mode and run the program.

Special Feature

SDP

  • The “Special Day Program” can be used when you are unexpectedly home and need to activate this heat/cooling program just for the day.
  • With the MODE switch in HEAT or COOL press the SPECIAL DAY button to activate.
  • When the SPECIAL DAY Program is active, all other day settings are ignored even if the day is matched.
  • The SPECIAL DAY program will terminate when the mode switch is moved or if the SPECIAL DAY button is pushed again.

Ritetemp Operation 8022C Thermostat Installation User Manual fig 9

Swing

Ritetemp Operation 8022C Thermostat Installation User Manual fig 10

  • The swing setting determines the temperature difference from ON to OFF that the thermostat will command the heating/cooling system to run.
  • With the MODE switch in HEAT or COOL, press the button.
  • The SET TEMP SWING icon is displayed. The current setting of the temp swing is shown on the display (default at 3 ).
  • To change the swing, push the TEMP UP or TEMP DOWN buttons. The furnace will cycle more at the lower numbers as it tries to keep your set point constant.
  • To complete the swing setting, push the HOME button.

Manual

Ritetemp Operation 8022C Thermostat Installation User Manual fig 11

  • With the MODE switch in HEAT or COOL, push the UP or DOWN arrow buttons to temporarily change the control temperature by 1 degree per step. Press and hold for faster setting.
  • The OVERRIDE icon comes on which shows the displayed temperature may be different from the programmed setting.
  • The OVERRIDE is canceled at the start of the next time period, or when the MODE switch is moved, or if TEMP HOLD is pressed twice.
TEMP HOLD

Change and hold the temperature until you return.

  • Open the door and push the TEMP HOLD button. The HOLD icon comes on. Push the UP or DOWN arrow buttons to set the hold temperature.
  • HOLD is canceled if the MODE switch is moved, or press TEMP HOLD again

Filter

The life of a heater filter varies depending on many factors, including furnace run time, and this will vary from the filter life noted on the filter media. The 8022C has a feature that keeps track of actual furnace run time and reminds you to periodically replace your system’s air filter.

  • Press the FILTER button once to review the current filter record. The FILTER and HR icons come on with accumulated filter hours being displayed.
  • Press Time to clear the record. Press again to recover the previous record.
    To see the filter limit setting, press and hold the FILTER button for two seconds.
  • To change the filter limit hours setting, press Ritetemp Operation 8022C Thermostat Installation User Manual fig 2. Press and hold for faster setting. The filter limit can be set within 000- 500 hours.
  • To leave the filter display, press HOME or wait 60 seconds.

Low Battery

  • When the batteries are low, the battery icon will come on and flash. The two AA Batteries in the unit need to be replaced.
  • Do not take longer than 30 sec to change the batteries in your unit or you will lose all custom settings and all programming. Only the Energy-StarTM program will remain. Once the batteries are replaced, the system will return to normal in 2 seconds.

C or F display

  • Centigrade / Fahrenheit selection. The C/F jumper is on the back of the thermostat control unit. Separate the control unit from the wall-mounted terminals.

12/24 hour 

Ritetemp Operation 8022C Thermostat Installation User Manual fig 12

  • The thermostat can display time in 12 or 24-hour formats.
  • The 12/24 jumper is on the back of the thermostat (see illustration).
Calibration

NOTE: Your thermostat comes from the factory calibrated to + or – 1o F actual temperature. It is an accurate instrument. To change the calibration:

  • The mode switch of the unit must be in the HEAT or COOL position.
  • Press the <Time button.
  • Press the Temp Up/Temp Down arrows to adjust the temperature reading.
  • Press HOME to save the new setting.

Ritetemp Operation 8022C Thermostat Installation User Manual fig 13