Aura Medical SI20 STEAM INHALER USER MANUAL
INDICATIONS FOR USE
The Avya is a portable Steam Inhaler designed to deliver warm and soothing aerosol mist for sinus and respiratory relief. Thank You for Purchasing Avya – The World’s Only Patented, Vibrating Mesh Technology Steam Inhaler. We’ve created a beautiful, ultra-portable, personal vaporizer that clears obstruction in the breathing path.
AVYA uses clean nanoparticle steam to go deep into your nasal, sinus, and throat passages to effectively clear sinuses, and relieve allergy, cold or flu-related symptoms. You can use AVYA anywhere- at home, at the office, on your run, at school, at the park, or on vacation. It’s time to stop the struggle and enjoy better breathing anywhere, anytime. This device should be used according to the instructions and not for any other purpose. Please read the instructions carefully before use.
WARNING AND CAUTION PRECAUTIONS
- Read instructions before using this device.
- Clean Avya before use. (See cleaning instructions)
- Clean Avya at the end of each day of use and store properly.
- This is a single-patient device. Do not allow multiple patients to use the same device.
- THIS UNIT IS DESIGNED ONLY FOR WATER-BASED SALINE FORMULATIONS. USING ESSENTIAL OILS OR OTHER LIQUIDS WILL DAMAGE THE DEVICE AND VOID THE PRODUCT WARRANTY!
- Do not attempt to clean the mesh with any foreign objects, follow cleaning instructions when cleaning the mesh.
- Do not store liquids overnight in the unit; this could cause clogging of the mesh.
- Do not immerse the control unit in water, wipe the control unit with a damp cloth to clean it it.
- Avoid dropping the unit, damage to the unit could occur.
- Keep the device out of the reach of infants and children. Children should use Avya only under an adult’s supervision.
- We recommend using Avya with our compatible aqueous solution.
DESCRIPTION OF DEVICE AND ACCESSORIES
- Main unit.
- Mouthpiece.
- Temperature increase
button. - Power the On/Off button.
- Temperature
indicator. - Temperature decrease button.
- Water Tank.
- Contact Electrode.
- Water Tank release button.
- Rubber cover.
- Battery indicator.
- DC jack socket.
- Battery.
- Mouthpiece.
- AC adapter and power cable
INITIAL USE
Before using Avya, the main unit and the accessories should be cleaned. Refer to Section Cleaning for instructions. Before use, ensure the device and accessories are at room temperature. Please note: The unit comes only 50% pre-charged for safety of transport.
ASSEMBLING THE WATER TANK
Remove the device from the packaging. Connect the water tank to the Steam Inhaler main unit. Make sure to connect firmly so that you hear a “click” sound (Fig. 1) To remove the water tank from the Avya main unit, press the button and pull the water tank upward simultaneously (Fig. 2)
INSERTING BATTERY PACK
Be sure to insert a battery pack as indicated on the inside door of the battery compartment. With normal use, a completely charged battery pack will power Avya for about 2 hours. The complete battery recharge time is approximately 3 hours. Ensure that the plastic pole protector is removed from the battery before inserting it into the device. Insert the battery pack (type 18650 2200mA x 4 units). The battery pack should be aligned to their respective poles (Fig. 3).
Ensure the battery pack is tightly fixed to the main device.
BATTERY RECHARGING AND STATUS
Please recharge the battery only with the supplied AC adapter. The AC adapter will automatically recharge the battery pack when plugged into the device. Please note that the battery pack will stop charging if the unit is powered ON for use. Always unplug the AC adapter when the battery pack is fully recharged to maintain the battery service life.
Note: When the battery is completely exhausted the power lights will flash 5 times and then power off the device. When the battery pack is completely recharged, the power lights will turn off to indicate unit readiness. Before using the battery pack, the plastic pole protector cover on the battery pack must be removed. ONLY use Avya’s supplied battery pack for the device. Tampering with the battery pack will void the product warranty. We recommend replacing the battery pack after one year of regular use. Always disconnect the AC adapter from the mains connection and the Avya unit before inserting the battery pack. Check the LED power status of the battery pack before use.
AC ADAPTER OPERATION
Note: Before using the AC Adapter, always check the data plate on the bottom of the Avaya device to ensure that the voltage and current indicated on the unit correspond to the voltage and current available. Connect the AC adapter only to the main voltage listed on the type plate. Insert the AC adapter connector into the connector socket provided, and the AC adapter fully into a suitable socket. Note: The device can operate without the battery pack when connected to the AC adapter. Ensure that there is a socket near where the device will be used. Ensure that the mains cable is not a tripping hazard. To disconnect the Avya Steam Inhaler from the mains after use, switch off the device first and then remove the AC adapter.
DEVICE OPERATION
Note: Before use, ensure the device and accessories are at room temperature.
Preparing Avya
For hygienic reasons, it is imperative that Avya and accompanying accessories are cleaned after every use. For details, see Section Cleaning.
Filling the Water Tank
- Open the water tank by lifting the latch.
- Pour Avya Aqueous Solution into the water tank.
- Close the water tank by pressing the latch firmly and securely back into place (Fig. 4)
Inhalation with the mouthpiece
- Connect the rubberized mouthpiece to the steam outlet (Fig. 5)
- Sit upright and hold the device as upright as possible, do not tilt the device more than 45 degrees in any direction (Fig. 6)
- Place Avya at a comfortable angle under your nose
- Power the unit by simply touching the power indicator.
- Adjust the temperature control by touching the “+” or “-“ button and the temperature LED will light up (Fig. 7).
CLEANING
Note: The Avya Steam Inhaler device and accessories are intended for multiple use. Before you clean the device, always switch it off, unplug it, and let it cool off. The Avya main device and the accessories used must be cleaned after each use. Cleaning the water tank and vibrating mesh element with the self-clean feature:
- Open the cover of the water tank and discard the remaining aqueous solution.
- Remove the water tank and rinse thoroughly.
- Insert the water tank in the reverse direction (Fig. 8).
- With a liquid dropper, drop 5-6 droplets of water onto the mesh element (Fig. 9).
- Power on the device. Avya will suction the water in reverse mode into the water tank and clear out any residue.
- Power Off the device and wipe the water tank dry.
Note:
NEVER ATTEMPT TO CLEAN THE MESH WITH ANY FOREIGN OBJECT, THIS COULD DAMAGE THE MESH AND WATER TANK. The unit will not operate with a damaged mesh.
CLEANING THE ACCESSORIES
Cleaning the accessories: Clean the accessories (mouthpiece) with diluted soap water and rinse. Allow to air dry completely Cleaning Avya main unit: Clean the outside of Avya device with a cotton cloth dampened with water. Do not allow water to enter the device. Cleaning the 4 stainless steel contact poles: Use a cotton swab dampened with water to clean the stainless steel contact electrodes on the Avya device (4 poles total – 2 poles on the main body and 2 poles underneath the water tank).
TROUBLESHOOTING MESH PROBLEMS
With time, the mesh holes may become blocked by unknown particles. You may notice a decreased output of vapor. To test: Put 6 ml. of water inside the water tank and power on the unit. If complete atomization time takes longer than 30 minutes, then the mesh holes are clogged. Solution A: To clean the mesh holes and unclog the blocked particles, put a solution of 2 drops of vinegar + 6 ml. of water into the water tank and allow the solution to vaporize completely.
Afterward, rinse and dry thoroughly before using it for a treatment. Solution B: Run the reverse self-cleaning procedure with a solution mix of 2 drops of vinegar to 4 drops of water (refer to the reverse self-cleaning instructions), If the problem persists after checking all possible causes, please contact an authorized distributor to purchase a new water tank Please refer to the table below to troubleshoot any problems.
Low atomization.
- Check to ensure there is water in the tank.
- Make sure the water tank is firmly in place.
- Clean mesh as recommended in the instructions.
- Clean electrodes on the control unit and water tank.
The power light goes out immediately after powering on.
- Make sure water cup is firmly in place.
- Clean electrodes on the control unit and water cup.
Power lights are on but no atomization.
- Clean mesh as recommended in the instructions.
- Check the mesh to see that it is not damaged.
- Clean electrodes on the control unit and water tank.
- Check fluid level.
- Re-install the battery pack.
- Tilt the unit forward.
Steam Inhaler shuts off during use.
- Make sure water cup is firmly in place.
- Clean electrodes on the control unit and water cup.
- Re-install the battery pack.
- The internal temperature is overheating. Turn off the device and cool it down for 10-20 minutes until the device is completely cool.
- The treatment period has exceeded 25 minutes. To activate the device, power the ON/OFF button for another treatment.
Leakage from the outlet of the mouthpiece.
Open the residual port located on the bottom of the unit to allow accumulated water to be released. If your Avya Inhaler still does not function properly after troubleshooting, follow warranty service instructions.
TECHNICAL SPECIFICATIONS
- Product Name: Avya Portable Steam Inhaler
- Model: SI20
- Method of Operation: Vibrating Mesh
- Dimensions (LxWxH): Approx. 52.5 x 52 x 126mm
- Device weight: **** excluding batteries
- Battery Life: Approx. 2 hrs (from 100%)
- Recommended Fill: Approx. 20 ml maximum
- Atomization rate: Approx. 0.25 ml/min minimum
- Oscillation frequency: 100 kHz
- Mains connection: 100-240 V ~, 50-60 Hz;
- Power Consumption: **** VA
Operating conditions
- Temperature: 50° ~ 104°F 10°C ~ 40°C)
- Humidity: 30%-85% R.H. non-condensing
Storage and transport conditions
- Temperature: -4°~ 158°F (-20°C ~ +70°C)
- Humidity: < 85% R.H. non-condensing
- Atmosphere pressure 860hPa~1060hPa
- IPx1 Degrees of protection against ingress of water and access to hazardous parts
WARRANTY AND SERVICE
The Avya Steam Inhaler unit is warranted for one year from the date of purchase against defects in manufacturing. All warranties are based on normal usage. The warranty does not cover wearable accessories. This warranty covers normal usage, failure to adhere to and/or comply with operation manual instructions will void all associated warranty obligations under the terms of this warranty, Conditions for voiding this warranty include:
- Abuse
- Failure to follow directions
- Misuse
- Improper maintenance
- Ordinary wear
For warranty and service please contact AURA MEDICAL LLC at 516.253.1063 to speak to a representative or find us online at www.aura-medical.com/support
ELECTROMAGNETIC COMPATIBILITY INFORMATION
EMISSIONS | COMPLIANCE | Electromagnetic environment – guidance |
RF emissions CISPR 11 | Group 1 | The MODEL SI20 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. |
RF emissions CISPR 11 | Class B | The MODEL SI20 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. |
Harmonic emissions IEC 61000-3-2 | Class A | |
Voltage fluctuations /flicker emissions IEC 61000-3-3 | Complies |
Immunity Test | IEC 60601-1-2 test level | Compliance level |
Electrostatic discharge (ESD) IEC 61000-4-2 | ±8 kV contact ±2 kV, ±4 kV, ±8 kV, ±15 KV air | ±8 kV contact ±2 kV, ±4 kV, ±8 kV, ±15 KV air |
Radiated RF EM fields IEC 61000-4-3 | 10V/m 80MHz-2.7GHz 80% AM at 1kHz | 10V/m 80MHz-2.7GHz 80% AM at 1kHz |
Electrical fast transient/burst IEC 61000-4-4 | ±2 kV 100 kHz repetition frequency | ±2 kV 100 kHz repetition frequency |
Surge IEC 61000-4-5 | ±0.5 kV, ±1 kV line-to-line; ±0.5 kV, ±1 kV and ±2 kV line-to-ground | ±0.5 kV, ±1 kV line-to-line; ±0.5 kV, ±1 kV, and ±2 kV line-to-ground |
Conducted distur- bances induced by RF fields IEC 61000-4-6 | 3V 0.15MHz-80MHz 6V in ISM and amateur radio bands be- tween 0.15MHz and 80MHz, 80% AM at 1kHz | 3V 0.15MHz-80MHz 6V in ISM and amateur radio bands be- tween 0.15MHz and 80MHz, 80% AM at 1kHz |
Immunity Test | IEC 60601-1-2 test level | Compliance level |
Voltage dips, short interruptions, and voltage variations on power supply input lines IEC 61000-4-11 | 0% UT: 0.5 cycle a) At 0o, 45o, 90o, 135o, 180o, 225o, 270o, and 315o. | 0% UT: 0.5 cycle a) At 0o, 45o, 90o, 135o, 180o, 225o, 270o, and 315o. |
0% UT: 1 cycle 70% UT: 25/30 cycles Single phase: at 0o | 0% UT: 1 cycle 70% UT: 25/30 cycles Single phase: at 0o | |
0% UT: 250/300 cycles | 0% UT: 250/300 cycles | |
NOTE: UT is the a.c. mains voltage prior to application of the test level Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment or For ME EQUIPMENT and ME SYSTEMS that are used in the home healthcare environment. |
Test Freq. (MHz) | Band (MHz) | Service a) | Modulation b) | Max Power (W) | Distance (m) | Immunity test level (V/m) | Compliance level |
385 | 380-390 | TETRA 400 | Pulse Modulation 18 Hz | 1.8 | 0.3 | 27 | 27 |
450 | 430-470 | GMRS 460 FRS 460 | FM c) ±5kHz deviation 1 kHz sine | 2 | 0.3 | 28 | 28 |
710 | 704-787 | LTE-Band 13, 17 | Pulse Modulation 217 Hz | 0.2 | 0.3 | 9 | 9 |
745 | |||||||
780 | |||||||
810 | 800-960 | GSM 800/900; TETRA 800; Iden 820; CDMA 850; LTE 5 | Pulse Modulation 18 Hz | 2 | 0.3 | 28 | 28 |
870 | |||||||
930 | |||||||
1720 | 1700-1990 | GSM 1800-1900; CDMA 1900; DECT, LTE 1, 3, 4, 25; UMTS | Pulse Modulation 217 Hz | 2 | 0.3 | 28 | 28 |
1845 | |||||||
1970 | |||||||
2450 | 2400-2570 | Bluetooth, WLAN, 802.11 b/g/n; RFID 2450; LTE 7 | Pulse Modulation 217 Hz | 2 | 0.3 | 28 | 28 |
5240 | 5100-5800 | WLAN 802.11 a/n | Pulse Modulation 217 Hz | 0.2 | 0.3 | 9 | 9 |
5500 | |||||||
5785 |
REFERENCE LINK