Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-featuredimg

Arovec AroMist-TF4 Ultrasonic Top-Fill Cool Mist Humidifier Manual

Arovec-logo

Arovec AroMist-TF4 Ultrasonic Top-Fill Cool Mist Humidifier Manual

Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-prduct-img

This user manual provides safety and operating instructions. Please read this user manual thoroughly before using the product. This user manual will help get your dehumidifier going in just a few quick minutes.

PACKAGE CONTENTS 

  • 1 × AroMist-TF4 Humidifier
  • 1 × Remote Control
  • 5 × Aroma Pad
  • 1 × User Manual
  • 1 × Warranty Card

PRODUCT SPECIFICATIONS

Power Supply220 – 240 V , 50 Hz
Rated Power25 W
Standby Power< 1 W
Water Tank Capacity4.0 L
 

Mist Volume

Low: 100 ml/H

Medium: 200 ml/H

High: 300 ml/H

Noise Level≤ 25dB
Coverage Area10-30 m2
Running Time12-40 hours*
Night LightOptional LED Light
Net Weight1.8 kg
Product Dimensions19 × 19 × 32 cm
Essential Oil DiffuserEssential Oil Tray
Cord Length1.5 m

IMPORTANT SAFETY INSTRUCTIONS

Please read all instructions before use to prevent the risk of injury, fire, electric shock, or damage. Use your dehumidifier safely by following the instructions in this manual.

  • ALWAYS turn off and unplug the dehumidifier before emptying the water tank.
  • DO NOT move the dehumidifier when the water tank is full to prevent water spillage.
  • DO NOT use the dehumidifier if it has been dropped, damaged, left outside, dropped in water, or not working properly.
  • DO NOT turn on the dehumidifier when the water tank is removed from the unit.
  • DO NOT remove the water tank when the dehumidifier is turned on.
  • DO NOT use the dehumidifier if the cord or adapter looks damaged.
  • DO NOT use the dehumidifier near gas appliances, fireplaces, stoves, candles, or heating devices.
  • DO NOT use the dehumidifier in an area with insect repellents, burning incense, toxic fumes, flammable dust, or oxygen tanks. Always leave at least 1.5m of clear space from any oxygen being administered.
  • DO NOT run the power cord under furniture, other appliances, carpet, or cover with rugs, runners, or floor covering.
  • ALWAYS tuck away the power cord to prevent tripping accidents.
  • DO NOT put the dehumidifier on an unstable surface e.g. bed or couch.
  • DO NOT use the power adapter on wet or damp surfaces.
  • DO NOT touch any part of the humidifier or adapter with wet hands.
  • DO NOT put the dehumidifier in water or liquids.
  • DO NOT use the dehumidifier outdoors.
  • DO NOT use it for commercial purposes. This appliance is for households only.
  • DO NOT put any object into the air inlet/outlet.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions of the dehumidifier, as this may cause danger and void the warranty.
  • DO NOT sit on the dehumidifier or put any object on the top of the unit.
  • DO NOT block/obscure the air inlet/outlet. Keep free of anything that could reduce airflow.
  • DO NOT spray air fresheners, perfumes, or oils on or near the dehumidifier.
  • DO NOT fit the dehumidifier with a different power supply unit.
  • DO NOT clean with the power adapter plugged in.

INTRODUCTION

The AroMist-TF4 ultrasonic cool mist humidifier generates a relaxing and scented mist that moisturizes the air with calming aromatherapy.

Product Features:

  • Humidifier: Cool mist moisturizes and refreshes the air in your home or office. This Arovec humidifier uses advanced ultrasonic technology to turn water into a therapeutic cool mist.
  • Aromatherapy: Enjoy the ultimate aromatherapy experience using your favorite essential oil (oil not included in the package). This is an additional feature of this humidifier and is not required to run the unit.
  • Top-Fill Design: The large water tank opening at the top of the humidifier is a unique feature of the AroMist-TF4 that allows easy refilling and cleaning of the water tank.
  • 360° Rotatable Nozzle: The nozzle on top of the humidifier is adjustable all around, so you can easily point it in the direction in which you would like the mist aimed.
  • Removable Water Tank: The water tank with a handle can be easily removed for refilling and cleaning.
  • Auto Shut-OFF: The humidifier automatically turns off when running out of water to avoid damage to the unit.
  • Sleep Mode Function: Sleep mode turns off all display indicators & lights and the unit runs quietly without disturbing your sleep.
  • Remote Control: It features a remote control to easily operate and control the machine conveniently.
GETTING TO KNOW YOUR HUMIDIFIER

Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-1

GENERAL TIPS 

  • DO NOT place the humidifier on the carpet, towel, or soft surface, which will block the air inlet and may damage the humidifier. For more efficiency, place the humidifier on a flat surface, 60 cm away from the floor and 30 cm away from the wall.
  • DO NOT place the humidifier on wooden furniture as it may be damaged by water.
  • DO NOT put the humidifier on an unstable surface e.g. bed or couch. [Figure 1.1]
    Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-2
  • DO NOT add water to the humidifier through the mist outlet or base. [Figure 1.2]
    Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-3
  • DO NOT direct the mist nozzle against the wall or window. [Figure 1.3]
    Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-4
  • The most comfortable relative humidity is between 40% – 60%. Please adjust the mist level as needed. [Figure 1.4]
    Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-5
  • DO NOT add essential oil directly into the water tank or base. Only add the recommended drops of essential oil to the oil tray. [Figure 1.5]
    Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-6
  • Using tap water with a high mineral content (hard water) in any humidifier can cause fine white dust to be emitted. To avoid this, use distilled, demineralized, or cold-boiled water. Room temperature water is recommended, do not fill with hot water.
  • DO NOT move the humidifier while it is still running and when the water tank is full to prevent water spillage. [Figure 1.6]

Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-7

OPERATION

Follow the below steps to easily and effectively use the AroMist-TF4 humidifier

Add Water:

  • Remove the top cover from the humidifier. Fill the water tank with cold or room-temperature water. DO NOT fill above the “MAX” level. [Figure 2.1]
    Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-8
  • Optionally, add 5 to 10 drops of essential oil into the oil tray. For best results, it is recommended to use pure essential oil. [Figure 2.2]

Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-9

Setting Up The Remote Control:
Pull the plastic film from the battery compartment. The battery is now active, and you can use the remote control. [Figure 2.3]

Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-10

Changing The Battery:

  1. Push the release button inwards and pull the battery casing out. Remove the old battery.
  2. Insert 1 x CR2025 3V battery into the battery casing ensuring you follow the polarity (+ and -) marked on the casing. [Figure 2.4]
    Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-11
  3. Slide the battery casing back into the remote control until you hear it click firmly into place.

Control Panel & Display:

Plug the humidifier into an electrical outlet.

Plug the humidifier into an electrical outlet.

DISPLAY

  • The display shows the current relative humidity (%RH) in the air.

POWER BUTTON

  • Press once the (Arovec-AroDry-1800-Air-Dehumidifier-User-Manual-fig-5 ) to turn the dehumidifier ON or OFF

HUMIDITY BUTTON

  • Press the ( Arovec-AroDry-1800-Air-Dehumidifier-User-Manual-fig-6) to adjust the desired relative humidity level (%RH) from 20%RH up to 80%RH.
  • The dehumidifier will operate until the selected %RH is achieved.

SLEEP & LIGHT BUTTON
Sleep-mode Feature:

  • In sleep mode, the dehumidifier runs quietly on the lowest fan speed and all indicators turn OFF including the night light. All the control panels will turn OFF and the dehumidifier will be working in dark mode.
  • Press the ( Arovec-AroDry-1800-Air-Dehumidifier-User-Manual-fig-7) to enter the sleep mode. The sleep indicator will blink for 5 seconds then the dehumidifier enters the sleep mode.

Night Light Feature:

  • Long press the ( Arovec-AroDry-1800-Air-Dehumidifier-User-Manual-fig-7) for 3 seconds to turn the night light ON or OFF.

Timer Bu�on:

  • You can set a timer for up to 12 hours.
  • Tap ( You can set a �mer for up to 12 hours. • Tap ( ) repeatedly to select a �mer. • The �mer display will automa�cally count down as �me passes. • The humidifier will automa�cally turn off once the �mer has finished coun�ng down. • To cancel the �mer, tap ( ) repeatedly un�l the �mer display disappears.) repeatedly to select a timer.
  • The timer display will automatically count down as time passes.
  • The humidifier will automatically turn off once the timer has finished counting down.
  • To cancel the timer, tap ( You can set a �mer for up to 12 hours. • Tap ( ) repeatedly to select a �mer. • The �mer display will automa�cally count down as �me passes. • The humidifier will automa�cally turn off once the �mer has finished coun�ng down. • To cancel the �mer, tap ( ) repeatedly un�l the �mer display disappears.) repeatedly until the timer display disappears.

Waterless Auto Shut-off 

  • When the water tank runs out of water, the humidifier will stop misting. It is designed for safety to prevent the humidifier from possibly overheating and damaging the atomizer.

USING ESSENTIAL OILS WITH AroMist-TF4

Enjoy the ultimate aromatherapy experience using your favorite essential oil (oil not included in the package). This is an additional feature of this humidifier and is not required to run the unit. Please follow the below recommendations for the proper use of essentials to avoid product malfunction/damage or any harm to the users.

  • Use 100% natural essential oil.
  • Add 5 to 10 drops of essential oil into the oil tray. DO NOT exceed the suggested amount of oil.
  • DO NOT add essential oil directly into the water tank or base. Only add the recommended drops of essential oil to the oil tray.
  • DO NOT spill essential oil on your skin. If you do, wash it off with water immediately.
  • DO NOT swallow the essential oil or contact with your eyes. If you do, wash your eyes and seek medical help immediately.
  • Pregnant women, elderly people, young children, or people with chronic diseases may be more sensitive to a particular fragrance. Stop using any essential oil that makes you feel unwell.
  • Keep the essential oil tightly closed and store it in a dark, cool place, out of the reach of children and pets.
  • Carefully observe the expiration date of the essential oil. The standard expiration date is one vear from the first opening for most oils However citrus oils have a 6-month expiration date.

CLEANING & CARE

Arovec recommends basic & deep cleaning regularly and daily water changes of AroMist-TF4 to prevent bacterial growth. DO NOT use any harsh cleaning agents e.g., bleach or alcohol to clean any part of the humidifier.

Basic Cleaning:
Arovec recommends basic cleaning the humidifier every 3 days.

  1. Turn OFF and unplug the humidifier from the power source.
  2. Remove and wash the top cover.
  3. Remove the water tank. Drain water from the tank and base. Pour water from the base carefully as the instructed corner of base face down. Flooding the electrical components can damage the device. Do not let water inside the air inlet/outlet or near the indicators. [Figure 3.1]
  4. Rinse the water tank and base with cool and clean water.
  5. Wipe down and dry all parts of humidifier with a soft cloth.

Deep Cleaning
Arovec recommends deep cleaning the humidifier every 2 weeks and before/after storing it for long periods of time. You should also deep clean if there is any mould or scale build-up inside the water tank or base. To properly clean your humidifier, Arovec recommends to remove scale/mould, disinfect the humidifier and clean the dustproof sponge.

  1. Turn OFF and unplug the humidifier from the power source.
  2. Remove and wash the top cover.
  3. Remove the water tank. Drain water from the tank and base. Pour water from the base carefully as the instructed corner of base face down. Flooding the electrical components can damage the device. Do not let water inside the air inlet/outlet or near the indicators. [Figure 3.1]
    Arovec-AroMist-TF4-Ultrasonic-Top-Fill-Cool-Mist-Humidifier-Manual-fig-14
  4. Fill the water tank about half way. Add in 1 teaspoon of undiluted distilled white vinegar into the water tank and allow to soak.
  5. Place the water tank back onto the base. Let the vinegar and water solution enter the base. This will help to loosen mineral scale/build-up on the atomiser, water floater and base of the water tank. Leave it for 20-30 minutes. [Figure 3.2]
  6. 6Remove the water tank from the base. Drain the solution from the water tank and base. Wipe water tank, atomiser, floater and base with a soft cloth to remove loosened scale.
  7. Flip the water tank over and clean the mist tube with a soft brush.
  8. Rinse the water tank and base thoroughly to remove any sediment, dirt and smell of vinegar.
  9. Wipe down and dry all parts of humidifier with a soft cloth
  10. For better performance, wash and clean the dustproof sponge (at the bottom of base) and oil sponge (in oil tray) with water at least once a month.

STORAGE 

If not using the AroMist-TF4 for an extended period of time, the following points
must be considered for safe storage:

  1. Ensure that the AroMist-TF4 is turned off and unplugged.
  2. Carefully clean the humidifier.
  3. Make sure the humidifier is entirely dried after cleaning.
  4.  Wrap the humidifier in plastic packaging and store it in a dry place to avoid moisture damage.

Note: Store the AroMist-TF4 in an upright position. Do not store anything on the top of the humidifier.

DISPOSAL
To prevent possible harm to the environment or human health from uncontrolled waste disposal, separate the unneeded dehumidifier and its related accessories from other types of wastes. Ask your local council where to dispose of your dehumidifier and its related accessories. You should not throw your dehumidifier and its related accessories away with the daily normal household waste.

TROUBLESHOOTING

Here are some tips to try if your humidifier isn’t working properly.

Problem !Possible Solution
 

 

 

AroMist-TF4 won’t turn on or

buttons not working

Plug into a powered electrical outlet.
Try plugging the AroMist-TF4 into a different outlet.
AroMist-TF4 or the cord might be damaged.
Make sure there is enough water in the water tank.
Clean the particles settlement from the water tank and base.
Water floater stuck. Adjust the water floater to a horizontal position and make sure it can rise up with water.
 

 

Air blows but water mist is not produced

Try plugging the AroMist-TF4 into a different outlet.
Check if there is enough water in the water tank.
Make sure the water tank is correctly attached to the base.
The base might be overfilled. Remove the water tank, drain the base water and replace the water tank on the empty base.
Mineral build-up on atomiser. Clean scale from atomiser.
 

 

Reduced mist level

The water in the unit is too cold, replace with room temperature water.
Do not fill with hot water, room temperature water is recommended.
Mist level is set too low for the room size. Adjust the mist level.
Close doors or windows to reduce air ventilation.
 

 

Water leakage

Water tank maybe damaged.
Water tank is not placed properly on the base.
Base water-level controller is stuck. Adjust the water-level controller to a horizontal position and make sure it can rise up with water.
 

 

The mist has bad smell

Clean the water tank and base thoroughly and fill the water tank with fresh water.
Wash and clean the oil tray and oil sponge for every oil change. unpleasant odour may produce if mixed with another essential oil.
Leave the empty water tank and base open in a cold place for 10 hours make sure the top cover is not attached to the water tank.
 

White dust is forming on nearby furniture

Hard water may deposit a certain kind of dust with any humidifier. Dust in the air also settles because of added humidity in the room.
Use distilled, demineralised or cold boiled water if this becomes a nuisance.
 

Mist height is low. Condensation forms around humidifier on desk, floor, windows or walls

Mist level is set too high for the room size. If the room is too humid, open door and windows and adjust to low mist level.
Low indoor temperature causes liquefaction.
Air inlet is blocked. Ensure the unit is placed on a hard, flat surface and air inlet is open.
Ensure the humidifier is placed 60 cm away from the floor and 30 cm away from sides.
 

AroMist-TF4 has stopped working

Check if there is enough water in the water tank.
Water floater stuck. Adjust the water floater to a horizontal position and make sure it can rise up with water.
AroMist-TF4 is getting too hotAroMist-TF4 is continuously working for too long time. Turn off for 15 minutes.
 

 

Increased noise level

AroMist-TF4 must be placed on a flat level and hard surface.
While the humidifier is working it may generate water noise as water is going down to the base. This is normal.
A foreign object might be stuck inside the AroMist-TF4.

 

WARRANTY INFORMATION

Arovec dehumidifiers are designed and manufactured to the highest quality standards. Your dehumidifier is covered for 2 year warranty, which includes 1-year standard warranty and 1-additional year, from the date of original purchase

Product nameAir Dehumidifier
ModelAroDry-1800
Standard warranty period1 Year
 

Additional warranty

Extend your warranty for 1-additional year. Simply register on to arovec.com.au/warranty within the first 14 days of original purchase.
Record your order details here. This will help if you have any warranty questions in the future.
Date of original purchase
Order number

TERMS AND CONDITIONS
In addition to your rights under the Arovec warranty, you are also covered by guarantees under Australian Customer Law. The Arovec warranty is only available in Australia. In Australia, our goods come with guarantees that cannot be excluded under the Australian Customer Law.

You are entitled to replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and failure does not amount to a major failure.

What is Covered

  • The repair or replacement of your Arovec dehumidifier (at Arovec’s discretion) if the product if found to be defective due to faulty manufacture. Arovec reserves the right to determine if the fault requires a replacement or repair.
  • Packaging and instructions for a faulty dehumidifier may also be replaced if damaged.
  • This warranty is valid for using your dehumidifier within Australia.
  • This warranty is valid for personal use only.
  • Warranties are limited to 2 years (1-year standard and 1-additional year) from the date of original purchase.

What is Not Covered

  • Using your dehumidifier for commercial purposes or anything other than normal domestic use.
  • Using your dehumidifier outside of Australia.
  • Accidental damage or faults caused by neglect, misuse, vandalism, and abuse.
  • Damage or faults are caused by not following the instructions in this user manual.
  • Unsupervised use by children under the age of 18.
  • Repairs or alterations carried out by parties other than Arovec or an authorized agent.
  • All other conditions that are not covered by Arovec warranty as listed in the “What is Covered” section.
This warranty is not transferable.

Arovec is not responsible or liable for any damages, losses, or inconveniences caused by product failure or accidental damage or faults caused by not following the instructions or safety warnings contained in this User Manual. Please email at support@arovec.com.au with any further inquiries about the Arovec warranty or to ask about making a warranty claim. You must contact us within your warranty period for your claim to be eligible.

DEFECTIVE PRODUCTS & RETURNS
Once your product is proven defective within the specified warranty period, stop using it and contact customer support at support@arovec.com.au with your order number.

CUSTOMER SUPPORT – AUSTRALIA
Please contact customer support with any questions regarding your product. Feel free to contact our helpful customer support team. Your satisfaction is our priority.

Customer Support:

  • Yasin Pty Ltd.
  • PO Box 2, Ermington NSW 1700, Australia
  • www.arovec.com.au
  • support@arovec.com.au
  • Please provide your order number when you contact customer support.

REFERENCE LINK

https://arovec.com.au/collections/all

 

Leave a Reply