AmazonBasics B073Q48YGF Standby UPS 600VA 360W User Manual
Contents:
Before getting started, ensure the package contains the following components:
Basic Operation
- Battery and Surge Protected Outlets
The unit has several battery and surge protected outlets (4 for 600VA and 6 for 800VA unit) to ensure temporary uninterrupted operation of your equipment during a power failure. (Do not plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical device into the “Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly damage the unit.). - Full-Time Surge Protection Outlets
The unit has several surge suppression outlets (4 for 600VA and 6 for 800VA unit) to provide surge and line noise protection. - Power Switch
- To turn the UPS on, press the power button for approximately 2 seconds – you will hear a constant tone (1 second) – and release after a short beep.
- To turn the UPS off, press the power button for approximately 2 seconds – you will hear a constant tone (1 second) – and release after two short beeps.
- Quickly press the POWER button twice can turn off or turn on the audible Alarm. The default setting is for the Alarm On.
- To turn the alarm off, press the power button twice. You will hear two short beeps when the alarm is turned off.
- To turn the alarm back on, press the power button twice. You will hear a short beep when the alarm is turned on.
- When the alarm is turned off, no audible notification when the UPS reaches a (low) battery state.
- Power On Indicator (green)
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes. When In the event of a complete power loss, severe brownout, or over-voltage, the UPS will turn to battery mode and the LED will flash. Please refer to the following “Definitions for Illumination LED Indicators” for more information. - Circuit Breaker
Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection. - USB Port to PC
The USB port allows connection and communication between the USB port on the personal computer and the UPS unit. The UPS communicates its status to the Power Management Software. - Outlets Designed for AC Adapters
The UPS unit has several widely-spaced outlets (2 for 600VA and 4 for 800VA unit), so AC power adapters can be plugged into the UPS without overlapping or blocking adjacent outlets
Important Safety Warnings
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
CAUTION!
- To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range).
- To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside.
- Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
- The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the unit.
- To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component.
- Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75.
- To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code, ANSI/NFPA 70.
- Risk of explosion if battery is replaced by an incorrect type. Batteries shall be installed by service personnel, and the replacement of batteries with a suitable recommended type. Dispose of used batteries according to the instructions.
- Do not dispose of batteries in a fire. The batteries may explode.
- Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
- DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! AmazonBasics does not sell products for life support or medical applications. Do not use in any circumstance that would affect operation and safety of life support equipment, any medical applications or patient care.
- DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.
- DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
- WARNING! This product contains chemicals known to State of California to cause cancer and birth defects or other reproductive harm.
- Not for use in a computer room as defined in Standard for the Protection of Electronic Computer/Data Processing Equipment, ANS/NFPA 75.
Installing Your UPS System
Unpacking
Inspect the UPS upon receipt. The box should contain the following:
- UPS unit
- User’s manual
- USB Cable
Power Management software is available on our website. Please visit amazon.com and go to the product page for free download.
How To Determine The Power Requirements Of Your Equipment
- Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity (600VA / 360W for AmazonBasics Standby UPS 600VA, 800VA/450W for AmazonBasics Standby UPS 800VA). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
- There are many factors that can affect the amount of power that your electronic equipment will require. For optimal system performance, keep the load below 80% of the unit’s rated capacity.
Hardware Installation Guide
- Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the battery’s maximum charge capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge whenever it’s turned on or turned off.
- With the UPS unit turned off and unplugged, connect your equipment requiring battery backup into the battery power supplied outlets. Plug the other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets. Do not plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical device into the “Battery and Surge Protected Outlets”. The power demands of these devices will overload and possibly damage the unit.
- Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).
- Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips, and surge strips in conjunction with the UPS.
- Press the power switch to turn the unit on. The Power On indicator will illuminate green and the unit will “beep” twice.
- If an overload is detected, an audible alarm will be sounded and the unit will emit long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
- To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
- To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in storage, recharge the battery every three months to ensure battery life.
- For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible.
- Do not lay the UPS on its side and please follow the direction as below to mount the UPS to ensure the battery life.
Technical Specifications
Model Standby UPS 600VA Standby UPS 800VA
Capacity 600 VA / 360 W 800 VA / 450 W
Input Voltage on Utility 96V typical – 140V typical
Input Frequency 50/60 ± 3 Hz (Auto-sensing)
Nominal Input Voltage 120 VAC
On-Battery Output Voltage 120 VAC ± 8 %
On-Battery Output Frequency 50 Hz / 60 Hz ± 1 %
Transfer Time 8 ms Typical
Max. Load for UPS Outlets 600 VA / 360 W 800 VA/450 W
Max. Load for Full-Time Surge
Protection outlets 10 Amps
On-Battery Output Wave Form Simulated Sine Wave
Operating Temperature + 32 °F to 104 °F / 0 °C to 40 °C
Operating Relative Humidity 0 to 95% non-condensing
Size (L x W x H) 10.7 x 3.1 x 6.1 in. (272 x 80 x 155 mm) 12.2 x 3.1 x 7.0 in. (310 x 80 x 178 mm)
Net Weight 6.53 lbs (2.96 kg) 9.23 lbs (4.18 kg)
Typical Battery Recharge Time 8 hours typical from total discharge
Typical Battery Life 3 to 6 years, depending on number of discharge/ recharge cycles
Recommended Battery Sealed Maintenance Free Lead Acid Battery
Safety Approvals UL, cUL, FCC Class B, ICES-003: Class B, CEC
REFRENCE LINK