Baldr-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-User-Guide-Feature-Image

Baldr B0359WST2H2PR-V1 Wireless Color Weather Station User Guide

Baldr-logo

Baldr-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-User-Guide-Image

Baldr B0359WST2H2PR-V1 Wireless Color Weather Station User Guide

PACKAGE CONTENT

  • 1 x Weather Station Main Unit
  • 1 x Remote Sensor
  • 1 x AC Adaptor
  • 1 x CR2032 Cell Battery
  • 1 x User Manual

OVERVIEW

MAIN UNIT

Baldr-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-User-Guide-Image-1

  1. Temperature and humidity of Channel 1/2/3
  2. Max/min record of Channel 1/2/3
  3. Indoor temperature and humidity
  4. Max/min record of indoor temperature and humidity
  5. Three comfort level indication
  6. Weather forecast: Weather forecast for next 12-24 hours
  7. Barometric Pressure: Barometer display in mmHg, inHg or hPa/mb
  8. Calendar display: Weekdays in 7 languages
  9.  Current time: 12/24 hour format selectable
  10. Channel scan
  11. Frost-point warning
  12. Button: Switch channel or clear sensors data and re-registration
  13. “ ▲” Button: Indoor temperature/humidity and barometric calibration or Increase the data
  14. “ ▼/RCC ” button:  RCC function or decrease the data
  15.  Button: Check alarm time, turn on/off alarm, enter into alarm setting
  16. Stand bracket
  17. Hanging Hole
  18. Battery Compartment

Notes:

  1. The default year is 2020, if the weekday display is incorrect . Please confirm year was set correctly. (for manual setting only)
  2. The CR2032 cell battery is for memory function (included). Please do not used as power supply. If you need to replace the cell battery, please take out the part device as shown in the figure below, load new battery matching the polarity(+and-).

Baldr-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-User-Guide-Image-2

OUTDOOR SENSOR

Baldr-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-User-Guide-Image-3

  1. Signal light
  2. Hanging hole
  3. Battery compartment
  4. Channel 1-2-3 switch

GETTING STARTED

BALDR recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.

MAIN UNIT INSTALLATION
Remove the cell battery’s Insulating strip, then plug the adaptor to a powered outlet.

SENSOR INSTALLATION

  1.  Remove the battery compartment cover;
  2.  Insert 2 x AA batteries in each sensor matching the polarity (+and-);
  3. Replace the battery cover.

SENSOR SETUP 

  • Switch the Channel 1-2-3 of the senor to any channel you want. For example, you can set to Channel 1 for the sensor. But please ensure the main unit are set to the same channel before synchronization. (Special note: Press “CH” button on the main unit to set the channel. The setting order is CH1–CH2–CH3–Channel scan (from CH1 to CH2 to CH3,10 seconds intervals),you must select the same number choices for both the sensor and the main unit in order for the units to synchronize).
  • Power the main unit prior to load the batteries of sensor.

Note:  Main unit will auto receive outdoor signal after power on, the receiving status will last for max 3 minutes. The receiving antenna signal will flash. If no signal received in 3 minutes, it will stop receiving outdoor signal.

MAIN UNIT SETUP
When power on or reset, LCD will full display for 3 seconds with “BI” sound. Then display Indoor temperature and humidity, barometric pressure with 100% backlight brightness.

RF Signal Receiving
After power on, It will start receiving outdoor sensor’ signal for 3 minutes. If signal received within 3 minutes or receiving window ends, it will enter into DCF signal receiving window.

DCF Signal Receiving

  1.  After RF signal receiving, it will start searching radio signal for 7 minutes with the antenna symbol “ ” displaying on screen. Meanwhile, the backlight brightness will automatically adjust to 5% (default brightness: 100%).
  2.  Once signal received, the main unit will display the received time/month/date/weekday with symbol “ ” displaying on screen.
  3. Daily RCC signal receiving: there are regular radio signal receiving at UTC 7:00AM,8:00AM, 9:00AM, 10:00AM, 11:00AM each day. It starts receiving signal at UTC 7:00AM everyday. For each day, once signal received at any one receiving time, it will stop receiving signal that day.
  4.  Manual receiving: press and hold “ ▼/RCC ” button to enter RCC signal receiving.
  5.  During receiving, press “ ▼/RCC ” button to exit RCC receiving.

Manual Settings

  1. Press and hold “ SET ” button to enter into setting, press “ SET ” button to skip setting steps or go to the next setting option.
  2. Press “ SET ” to select the RCC. Default setting : ON. Press “▲” or “ ▼/RCC ” button to select OFF or ON.
  3.  Press “ SET ” to select Time Zone. Default setting : -5(EST). Press “▲” or “ ▼/RCC ” button to select time zone: AST(-4),EST(-5),CST (-6),MST(-7),PST(-8),AKT(-9),HAT(-10) optional.
  4. Press “ SET ” to select DST ON/OFF. Default setting : ON. Press “▲” or “ ▼/RCC ” button to select DST ON if you do observe Daylight Saving Time.
  5.  Press “ SET ” to select 12/24H Time Format. Default setting :12 H. Press the “▲” or “ ▼/RCC ” button to select 12H or 24H.
  6.  Press “ SET ” to select Hours. Press “▲” or “ ▼/RCC ” button to adjust the value.
  7. Press “ SET ” to select Minutes. Press “▲” or “ ▼/RCC ” button to adjust the value.
  8.  Press “ SET ” to select Year. Press “▲” or “ ▼/RCC ” button to adjust the value.
  9.  Press “ SET ” to select Month& Date display format. Default setting : M/D. Press the “▲” or “ ▼/RCC ” button to select M/D or D/M format. (M: Month ,D: Date)
  10. Press “ SET ” to select the Month. Press “▲” or “ ▼/RCC ” button to adjust the value.
  11.  Press “ SET ” to select the Date. Press “▲” or “ ▼/RCC ” button to adjust the value.
  12. Press “ SET ” to select Beep ON/OFF .Default setting :ON. Press the “▲” or “ ▼/RCC ” button to select ON/OFF.
  13.  Press “ SET ” to select the Barometric Unit. Default setting : inHg. Press “▲” or “ ▼/RCC ” button to select unit: mmHg, inHg or hPa/mb optional.
  14.  Press “ SET ” to confirm and exit.
  15. During setting, touch top button to save and exit setting.
  16. During setting, if no operation for 20 seconds, it will automatically save and exit setting.

ALARM FUNCTION

Alarm Time & Snooze Setting

  1. Press and hold “ ” button to enter into alarm time and snooze setting.
  2. Press “▲” or “ ▼/RCC ” button to adjust data; press and hold “▲” or “ ▼/RCC ” button will quickly change the value by 8 steps.
  3. The setting order is: Hour → Minute→Snooze Interval time → Exit.
  4. Snooze interval time : 5~60 minutes can be set, Default setting : 5 minutes.
  5.  During setting, touch top button to save and exit setting.
  6.  During setting, if no operation for 20 seconds, it will automatically save and exit setting.
  7. The alarm is default ON after setting the alarm time. Alarm symbol will display on screen.

Alarm ON/OFF Setting 

  1. When in alarm time display mode, press button to turn on/off the alarm by the ON/OFF of symbol .
  2.  When in time display mode, press button to check alarm time. Press button twice to turn ON/OFF alarm by the ON/OFF of symbol .
SNOOZE FUNCTION 
  1.  When the alarm is ringing, press any other button except top button to stop the alarm. And the alarm will restart next day.
  2. Or when alarm is ringing, press the top button to activate snooze function. The alarm will ring again in snooze interval time as you set before. And the “ ” symbol will be flashing on screen to indicate the snooze mode. Press any other button except top button to exit the snooze mode. And the alarm will restart next day.
  3.  When alarm rings, the ascending “Bibi” alarm sound will last for 2 minutes if no operation.

OPERATION GUIDELINES

MAX AND MIN RECORD 

  1. Press “MEM” button to check maximum temperature and humidity, the value will display for 5 seconds.
  2.  Press “MEM” button second time to check the minimum temperature and humidity, the value will display for 5 seconds.
  3.  Press “MEM” button third time will return to standard mode.
  4. Press and hold “MEM” button will clear the max and min record and reactivate the memory.
  5.  During setting, if no operation for 5 seconds, it will automatically save and exit setting.
  6.  Normally, the Max and Min record will update every 24 hours at 0:00.
TEMPERATURE 
  1.  After power on ,the indoor temperature will display automatically, it will update reading each 30 seconds and start to receive outdoor signal which lasts for max 3 minutes.
  2.  Indoor temperature display range:14℉~ 122℉(-10℃~ 50.0℃); for temperature lower than 14℉,the reading will be :“LL.L”; for temperature higher than 122℉,the reading will be :“HH.H”.
  3. Outdoor temperature display range :-40℉~140℉(-40℃~60℃); for temperature lower than -40℉,the reading will be :“LL.L”; for temperature higher than 140℉,the reading will be :“HH.H”.
  4.  Arrow indication for temperature changes:
    • will display when temperature changes less than 1.8℉ within one hour or compared with last reading;
    • will display when the reading increase by 1.8℉ within one hour or compared with last reading.
    • will display when the reading decrease by 1.8℉ within one hour or compared with last reading.
  5.  Accuracy: For temperature between 32℉~122℉,the accuracy is±1.8℉,if out of this range the accuracy will be ±3.6℉ ; Temperature resolution is 0.1℉(0.1℃).
  6. Press “SET ” button to switch from Celsius degree to Fahrenheit degree.

HUMIDITY 

  1.  After power on ,the indoor humidity will display automatically, it will update reading each 30 seconds and start to receive outdoor signal which lasts for max 3 minutes.
  2. Humidity display range: 1%-99%;for humidity lower than 1%,the reading will be “1%”;for humidity higher than 99%,the reading will be “ 99%”.
  3. Accuracy: when the temperature is between 68℉~ 78.8℉(20℃~ 26℃) and the humidity is between 40-80%,the accuracy is ±5%,if out of this range the accuracy will be ±8%.

BAROMETRIC PRESSURE 

  1.  Barometer range: 25.1-31inHg (646-798mmHg, 850-1050 hPa/mb).
  2. Press and hold “SET ” button to switch barometric unit ( please refer to Manual Settings Point 15) .

WEATHER FORECAST

  • The weather forecast icon will show after power on. There are 5 kinds of weather modes: Sunny, Sunny To Cloudy, Cloudy, Rainy, Snow. The weather icon displays are based on the hourly calculation of indoor/outdoor temperature & humidity and barometer data. The forecast is for next 12 hours with 70%-75% accuracy.

Baldr-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-User-Guide-Image-4

FROST-POINT ALERT

  • When current outdoor channel’s temperature is in the range of 32℉ ~37.22℉(0℃~ 2.9℃),the alert symbol “ ” will be flashing until the temperature reading is higher than 37.22℉; the symbol will keep displaying on screen if temperature is lower than 32℉

MOON PHASE

Baldr-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-User-Guide-Image-5

CALIBRATION
Baldr weather stations were calibrated precisely at our manufacturing facility, but if you want the data of this product to be consistent with the reading of the equipment you are more trusted or more used to, you can manually calibrate the indoor temperature, humidity and barometer values.

  1.  When in time display mode, press and hold “▲” button to enter Calibration mode.
  2. Press and release the “SET” button to confirm and move to the next setting: Indoor Temperature →Indoor Humidity→ Barometer → Exit.
  3. Press “▲ ” or “ ▼/RCC ” button to adjust the value.
  4.  Indoor temperature calibration range : ±5 ℃ ; Indoor humidity calibration range: ± 10 %RH; Barometer calibration range: ±10 hPa.
  5. During setting, you can press “MEM” button to clear all correction values.
  6. During setting, touch top button to save and exit setting. If no operation for 20 seconds, it will automatically save and exit setting.

ADJUSTABLE BACKLIGHT

  • After powering on, touch “ ” button to adjust the brightness of the backlight.
  • Backlight brightness can be selected from 5%,60%,100% and off.

LOW BATTERY INDICATORS

  • About Outdoor Sensor: When battery indicator shows next to the outdoor temperature, replace batteries in your outdoor sensor.
  • About Cell Battery in Main Unit: The CR2032 cell battery is only for memorizing the setting during sudden power outage. When battery indicator shows next to your Indoor Temperature, replace battery.

FEATURES

  • Clear color LCD display
  • WWVB atomic time
  • Weather forecast for next 12-24 hours with barometer
  • Measures in/out humidity and temperature (℉/℃)
  • Up to 3 RF channels for outdoor sensors (only one sensor included)
  • Max/min record of temperature & humidity
  • Comfort level indication
  • Indoor temperature range: 14℉~122℉(-10℃~50℃)
  • Outdoor temperature range:-40℉~140℉(-40℃~60℃)
  • In/outdoor humidity range: 1%-99%
  • Calendar, alarm and snooze function
  • Time display in 12/24H
  • Calendar function with Month/Date or Date/Month display format selectable
  • White backlight with dimmer

TROUBLESHOOTING

ProblemPossible Solution
Outdoor reading is flashing or showing dashesFlashing of the outdoor reading is generally an indication of wireless interference.
  1. Bring both the sensor and display indoors, side by side and remove batteries from each.
  2. Make sure the 1-2-3 switch on both units match.
  3. Reload batteries in outdoor sensor.
  4. Reload batteries in main unit.
  5. Let both units sit within a couple feet of each other for a few minutes to gain a strong connection before taking sensor to outdoor area.
No outdoor sensor reception
  1. Reload the batteries of both outdoor sensor and main unit. Please refer to the SENSOR SETUP section.
  2. Relocate the main unit and/or the outdoor sensor.
The units must be within 328ft(100m) of each other.
  1. Make sure both units are placed at least 3 ft (0.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).
  2. Use standard alkaline batteries. Do not use heavy duty or rechargeable batteries.
Inaccurate temperature/ humidityMake sure both the main unit and sensor are placed out of direct sunlight and away from any heat sources or vents.
“HH.H/LL.L” display in indoor and/or outdoor temperatureIf the temperature is higher than the detection range, “HH.H” will display on screen for indication; if lower than the detection range, “LL.L” will display on screen for indication.

FAQS

How does my weather station work?
At the most basic level, an automatic weather station works by measuring atmospheric conditions and transmitting them to a network, forecaster, or display. They use special instruments to measure the surface weather observations we mentioned above.
How do I reset my weather station?
Condition so after the 15 minutes insert new batteries into the sensor. And then into the back of the station. And then finally reconnect the power.
Some weather stations connect to a central server or data collection system via a wired network (e.g., Ethernet) and therefore do not require a wireless network
Why is my weather station flashing?
If the forecast icon is flashing, this indicates there is a rapid drop in barometric pressure, and a storm is predicted.
How do I set weather clear?
Just type slash weather. And then type clear. That’s. It just slash weather clear. Now for whatever reason you do need some rain you can type slash weather rain.
How do I add a weather station to Weather Underground?
Create an account on WUnderground.com and Add New Device. Select the correct device hardware under Personal Weather Station then enter the requested information. Once your station is created you will be provided with a Station ID and Station Key.
What is the principle of a weather station?
Weather stations are devices that utilize meteorological sensors to measure various environmental parameters such as temperature, humidity, pressure, wind speed, wind direction, and precipitation.
What are the disadvantages of the automatic weather station?
  • Accuracy and Calibration
  • Maintenance and Downtime
  • Limited Spatial Coverage
  • Environmental Considerations
  • Cost and Accessibility
What affects location of a weather station?
Wind, air temperature, and water vapor pressure measurements are affected by surface type and roughness, soil moisture, regional topography, and obstructions.
What is the main purpose of weather station?
A weather station is a facility, either on land or sea, with instruments and equipment for measuring atmospheric conditions to provide information for weather forecasts and to study the weather and climate.