BN-LINK BND-60/U110 Digital In-wall Timer Switch User Manual

BN-LINK logo

BN-LINK BND-60/U110 Digital In-wall Timer Switch User Manual

BN-LINK BND-60U110 Digital In-wall Timer Switch User Manual prduct img

PRODUCTS VIEW

BN-LINK BND-60U110 Digital In-wall Timer Switch User Manual fig 1

  1. Countdown Program Button: Press to start a countdown program.
  2. ON/OFF Button: Manually turn ON/OFF or override a running program.
  3. 24-Hr Repeat Button: Activate or deactivate the daily repeat of a program.

There are 8 buttons on the main panel: 6 countdown buttons, an ON/OFF button, and a REPEAT button. Configuration of the countdown buttons varies in different sub-models: U110a-1: 5Min, 10Min, 20Min, 30Min, 45Min, 60Min U110b-1: 5Min. 15Min. 30Min. 1Hour. 2Hour, 4Hour.

TECHNICAL SPECIFICATIONS

  • 125V~,60Hz
  • 15A/1875W Resistive, 10A/1250W Tungsten,
  • 10A/1250W Ballast, 1/2HP, TV-5
  • Operating temperature: 5°F- 122ºF(-15 °C-50°C)
  • Storage temperature: -4°F-140°F (-20 °C-60°C)
  • Insulation class: I|
  • Protection class: IP20
  • Clock accuracy: ‡ 2 minutes/month

A WARNING

  • Single Pole: The timer will control devices from one location. Do not use in a 3-way application where multiple switches control the same device.
  • Neutral Wire: This is a wire that must be available as part of the wiring in the building. The timer will not function properly if a neutral wire is not available in the wall box.
  • Direct Wire: This timer is only intended to be permanently installed into an electrical wall box.
  • To avoid fire, shock, or death, turn off the power at the circuit breaker or the fuse box before wiring.
  • Installation by a licensed electrician to local, state, and national codes is recommended.
  • For indoor use only.
  • Do not exceed electrical ratings.

INSTALLATION

  1. Turn off power at the circuit breaker or fuse box before uninstalling the existing device or installing a new timer.
  2. Remove the existing wall plate and switch from the wall box.
  3.  Make sure the following 3 wires are present in the wall box.
    a. 1 Hot Wire from the circuit breaker box
    b. 1 Load Wire to the device to be powered
    c. 1 Neutral Wire
    If these are not present, this Timing Device will not function properly. Additional wiring to the wall box will be required before installation of this timer can be completed.
  4. Strip wires 1/2-inch long.
  5. Use the included wire nuts and securely twist them together to attach the timer wires to the building wires.

Wring

BN-LINK BND-60U110 Digital In-wall Timer Switch User Manual fig 2

BN-LINK BND-60U110 Digital In-wall Timer Switch User Manual fig 3

OPERATING INSTRUCTIONS
  1.  Initialization: When the timer is first powered, all the indicators will illuminate and then go out after the self-diagnosis process. There is no power output at this stage.
  2. Setting a countdown program: Simply press the button that represents a desired countdown program, the indicator on the button illuminates and the countdown starts. The timer will output power and then cut it off when the countdown process ends. Pressing repeatedly the same button before the countdown ends will not restart the countdown.
    BN-LINK BND-60U110 Digital In-wall Timer Switch User Manual fig 4
    Example: The 30-minute button is pressed at 12:00, pressing this button before 12:30 will not restart the countdown program.
  3. Shifting to another countdown program
    Example: Press the 1-hour button while a 30-minute program is already in the run. The indicator on the 30-minute button will go out and the indicator on the 1-hour button will illuminate. The timer will output power for 1 hour. The power output will not be cut off during the shift.
  4. Activating the daily repeat function Press the REPEAT button when a countdown program is running, and the indicator on the REPEAT button illuminates, indicating that the daily repeat function is now active. The current program will run once again at the same time on the next day.
    BN-LINK BND-60U110 Digital In-wall Timer Switch User Manual fig 5
    Continued

    Example: If a 30-minute program is set at 12:00 and the REPEAT button is pressed at 12:05, the 30-minute countdown program will run every day at 12:05 from the next day on.

  5. Deactivation of the daily repeat function Follow either way below to turn off the daily repeat function. a. Press the REPEAT button, and the indicator on the button will go out. This will not affect an ongoing program. b. Press the ON/OFF button to end the ongoing program as well as the daily repeat function. Note: When a countdown program is in the run with the daily repeat function active, pressing another countdown program button will start a new countdown process and deactivate the daily repeat function.
  6. Termination of a countdown program. A countdown program terminates in the following 2 conditions: a. When the countdown program completes, the indicator goes out and the power output is cut off. b. Press the ON/OFF button at any time to terminate a countdown program. This operation also deactivates the daily repeat function.
    BN-LINK BND-60U110 Digital In-wall Timer Switch User Manual fig 5
    Continued
  7. Always-ON If a countdown is already in the run or the daily repeat function is active, press ON/OFF twice to set the timer to ALWAYS ON. If the timer is in OFF mode, press ON/OFF once.
    Note: In ALWAYS ON mode, the indicator on the ON/OFF button illuminates and the power output is permanent.
  8. Terminating ALWAYS ON a. Press the ON/OFF button. The ON/OFF indicator goes out and the power output is cut off, or, b. Press a countdown program button.
  9. Restarting a running countdown program a. Press ON/OFF to terminate the program and then press the countdown button, or b. Press another countdown button and then the previous countdown button, or c. Activate the daily repeat function (if it is already active, please deactivate it first) and the current countdown process will restart. If the daily repeat function is not needed, please press the REPEAT button again.

TROUBLESHOOTING

When the product is powered, please check that all buttons and indicators operate properly. Please note that the REPEAT indicator illuminates only when a countdown program is active.

BN-LINK BND-60U110 Digital In-wall Timer Switch User Manual fig 56

BN-LINK INC.
  • 12991 Leffingwell Avenue, Santa Fe Springs
  • Customer Service Assistance: 1.909.592.1881
  • E-mail: support@bn-link.com
  • Http://www.bn-link.com
  • Hours: 9 AM – 5 PM PST, Mon – Fri
  • Designed in California Made in China

REFERENCE LINK

https://www.bn-link.com/products/bn-link-countdown-digital-in-wall-timer-switch-5-10-20-30-45-60mins-neutral-required-free-plate-white

DOWNLOAD PDF

BN-LINK BND-60/U110 Digital In-wall Timer Switch User Manual

Leave a Reply