Ozeri BP5K Automatic Wrist Blood Pressure Monitor User Manual
Introduction
- Thank you for your purchase of an Ozeri Fully Automatic Wrist Blood Pressure Monitor with Voice-Guided Operation.
- The unit includes an intelligent voice-guided feature to alert you of the proper positioning of your wrist for accurate blood pressure measurements. It also automatically provides an audible hypertension assessment via a new talking function as well as a display on the LCD screen.
- The unit uses the oscillometric method of blood pressure measurement. The oscillometric method detects the movement of your blood through your brachial artery and converts your blood pressure into a digital reading. The unit is simple to use because a stethoscope is not needed while using an oscillometric monitor.
- The unit stores automatically 180(2*90) sets of measurement values with the measuring date and time. You can read the stored data conveniently by pressing the memory button.
Important Safety Notes
To assure the correct use of the product, basic safety measures should always be followed including the precautions listed below:
- Read all information in the instruction manual and any other literature included in the box before using the unit.
- Consult your physician before measuring blood pressure, especially if you have any of the following conditions: hypertension, diabetes, arteriosclerosis,
- kidney or vascular disease, or any other condition affecting circulation.
- Operate the unit only as intended. Don’t use it for any other purpose.
- The unit is intended for use in measuring blood pressure and heart rates for adults only. Do not use it on infants or persons who cannot express their intentions.
- Do not use a cellular phone near the unit. Cell phones may cause operation failure.
- Do not disassemble or attempt to repair the unit or components. Doing so will void the warranty.
- Do not use equipment where flammable gases (such as anesthetic gas, oxygen, or hydrogen) or flammable liquids (such as alcohol) are present.
Getting to Know Your Unit
Battery Installation
- Remove the battery cover from the battery compartment.
- Insert two new AAA batteries into the compartment and ensure the “+” (positive) and “-” (negative) polarities are correctly aligned.
- Replace the battery cover.
Caution!
- Use two identical 1.5V alkaline batteries type AAA LR03.
- Replace all of the batteries if the low battery symbol appears on the display.
- Never leave low batteries in the battery compartment as they may leak causing damage to the unit.
Initialization
- Initialization settings include user setting, year/date/time setting, a unit of measure, positioning sensor, and the voice/audio setting.
- This device automatically stores 180 sets of values for 2 users (2*90) with the date and time. Set all of the parameters before taking a measurement for the first time, otherwise, the unit will display the default values by the system.
Selecting the unit of measurement Selecting the unit of measurement
- The unit icon will appear on the screen after confirming the minutes for the time.
- The default unit of measurement is mmHg, which is the most commonly used in the USA. To change the unit of measurement to kPa, press the “MEM” button.
- Press the “SET” button to confirm the unit measure and proceed to the position sensor.
Setting the audio level for the voice guide Setting the audio level for the voice guide
The voice function of the Monitor is designed to work with the position sensor and aid you in finding the optimum positioning of your wrist before a measurement is taken.
- Press the “MEM” button to select a volume level between 0 and 7.
- When the volume is level 0FF, the LCD will display “ 0n” and the voice audio will be replaced by beeping audio to assist in proper positioning.
- Press the START/STOP “ ” button to save your settings and turn off the unit. Note: To turn off the beeping audible as well, you must turn the position assist sensor off.
Applying the Wrist Cuff
- Remove all clothes from your arm allowing the cuff to fit directly on the skin.
- Wrap the cuff firmly (0.4”) around your wrist by using the Velcro strip. Note: For reliable statistical record keeping, it is important that you consistently use the same arm for measurements.
- Turn your palm outwards as indicated below.
- Use your other wrist or another object to comfortably support your arm as shown below.
- Keep your wrist at the same level as your heart.
- Sit upright in a chair, and take 10 deep breaths to relax your hand, arm, and entire body. Then press the START/STOP “ ” button to turn on the unit and start the measurement.
Using the Memory Function
- This device stores the blood pressure and pulse rate in memory after each measurement. It automatically stores 180 measurements for 2 users (2×90). The earliest record is deleted to save the most recent measurement once 90 is reached.
To read the average value
- Press the “MEM” button, and the average value of the last 3 readings of the current user will display when the symbol “L3” appears.
- Press the “MEM” button two times, and the average value of all measurements of the current user will display.
- Press the “MEM” button three times, and the average value of AM measurement of the current user will display when the “AM” symbol appears.
- Press the “MEM” button four times, and the average value of the PM measurement of the current user will display when the “PM” symbol appears.
Troubleshooting
If the following symbols appear, please follow these recommended corrections
Symbol | Cause | Correction |
| Error occurs during inflating. | Reapply the wrist cuff and ensure a snug fit. |
Error occurs with measurement. | Be careful not to move arm or body during measurement. | |
Review the instructions and try another me.asurement. | ||
Battery power is too low. | Replace with 2 new AAA batteries. |
Common Problems
Problem | Causes and Solutions |
Won’t turn on. | Replace batteries with 2 new AAA batteries. |
LCD is blank. | Check the batteries to ensure +/- polarities are correctly aligned. Replace with 2 new AAA batteries. |
Measurement values appear too high or too low. | Blood pressure can vary based on stress, time of day, exercise, consumption of alcohol, smoking, tightness of the cuff, and other variables. A single measurement does not provide an accurate indication of blood pressure. Several readings are recommended. Always wait 3 or more minutes between measurements. |
Care and Maintenance
Care
- Keep the unit in the storage case when not in use.
- Clean the unit with a soft dry cloth. Do not use any abrasive or volatile cleaners.
- Store the unit in a safe dry indoor location
Maintenance
Never attempt to clean with abrasive or volatile liquids. | Do not wet the cuff or attempt to clean the cuff with water. |
| |
Store the unit in a clean and dry location. Do not subject the unit to extreme hot or cold temperatures, humidity and direct sunlight. | Remove the batteries if the unit will not be used for 3 months or longer. Always replace all of the batteries with new ones at the same time. |
Specifications
Model No. | BP5K | |
Display | LCD Digital Display | |
Measuring Principle | Oscillometric Method | |
Measurement Localization | Wrist | |
Cuff | Soft Wrist Cuff | |
Measurement Range | Pressure | 0 to 299 mmHg (0 ~ 39.9 kPa) |
Pulse | 40 to 180 Beats/min | |
Accuracy | Pressure | 3 mmHg (0.4 kPa) |
Pulse | 5% of reading | |
LCD Indication | Pressure | 3 Digit Display in mmHg or kPa |
Pulse | 3 Digit Display | |
Symbol | Memory/IHB/Heartbeat/Low Battery, etc. | |
Volume | Level 0 – Level 7
|
Voice-Guide | Assists in finding optimum wrist position | ||
Audible hypertension assessment | |||
Inflation | Automatic by Internal Pump | ||
Rapid Air Release | Automatic by Air Valve | ||
Memory Function | Memory 180 (2*90) Measurement Values | ||
Power Source | 2 AAA Alkaline Batteries; D.C.3V | ||
Automatic Power-Off | In 2 Minutes | ||
Gross Weight | Approx. 110g (Batteries not included) | ||
Operating Environment | Temperature | 10 ~ 40 C (50 ~ 104 F) | |
Humidity | 15 ~ 90%RH (Noncondensing) | ||
Storage Environment | Barometric Pressure | 105 ~ 80 kPa | |
Temperature | -20 ~ 60 C (-4 ~ 140 F) | ||
Humidity | 10 ~ 95%RH (Noncondensing) |
WARRANTY INFORMATION
Your Ozeri Blood Pressure Monitor, excluding the wrist cuff, is warranted to the original owner for 5 years from the date of purchase against defects in material and workmanship under normal use. The wrist cuff is warranted to the original owner for 1 year to be free from defects in material and workmanship under normal use.
Should your blood pressure monitor and/or wrist cuff appear defective within the applicable period from the date of purchase, return the defective unit, freight prepaid along with an explanation of the claim to Ozeri. Please pack carefully to avoid damage in transit. This warranty extends only to personal use and does not extend to any product that has been used for commercial use, or use which is not intended.
This warranty is not transferable. Ozeri is not responsible in any way for damages, losses, or inconveniences caused by equipment failure caused by user negligence, abuse, or use not in accordance with the “User Guide” or any additional safety, use, or warnings included in the product materials.
- Improper or inadequate maintenance. use.
- Damage in return transit.
- Unsupervised use by children under 18 years of age
- Ozeri Customer Service
- Customer service: 1-877-299-1296 (USA)
- Email: support@ozeri.com
REFERENCE LINK