Honeywell CL48PM Evaporative Air Cooler Manual
PARTS DESCRIPTION
- Water Inlet Hole
- Handle
- Left Side Grill
- Lever for Horizontal Louvers
- Water Tank
- Casters
- Louvers
- Water Level Indicator
- Control Panel
- Right Side Grill
- Water Inlet Valve
- Drain Plug
- Rear Grill
- Power Cord & Plug
- Rear Grill Screws
- Water Fill Door
- Honeycomb Cooling Media
CONTROL PANEL
SPEED / ON – OFF
Connect to the power supply and turn the SPEED knob. The fan will start. Change the speed from 3 to 1 (1 for Low, 2 for Medium, and 3 for High fan speed). To switch OFF the unit, turn the SPEED knob to 0.
COOL
You must add water before operating the unit in Cool mode. Turn the COOL knob to the ON position to activate evaporative cooling. The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet.
SWING
Turn the SWING knob to the ON position to activate the movement of the louvers. The louvers will begin to move left to right automatically. Vertical Air Flow – You can manually adjust the lever located at the front of the unit to change the vertical airflow.
COOLER LOCATION
Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide.
FILLING WITH WATER
It is ideal to use the Continuous Water Supply Connection to run the unit for long periods of time without refilling the tank. This also helps prevent pump failure in case the cooler is running with inadequate water in the tank.
Continuous Water Supply Connection:
For a continuous water supply, you will need a garden hose that is connected to a main water supply.
- Locate the male connector at one end of the garden hose. Insert the garden hose connector into the water inlet valve of the cooler. Screw and tighten the water inlet valve onto the threaded part of the garden hose connector, making sure the hose connector is secured to ensure there will be no leaks. If there is leakage, the hose, and the water inlet valve may not be connected properly. Try to disconnect, replace and tighten the water inlet valve again.
- When the connection is secured, turn ON the water supply and the water will flow into the water tank of the cooler.
- The cooler is now set so the water refills automatically when the water tank is empty, or when the water reaches below a minimum level.
- When the water tank is full, the water inlet valve will automatically stop the water supply from overflowing.
- Please open the water valve for minimum flow as too much pressure could damage the inlet pressure control system.
Manual Water Tank Refill:
- Using a portable container or a garden hose, you can refill the water tank manually by pouring water into the water tank through the water inlet hole located at the top of the air cooler.
- Check the water level indicator to know when the water tank is full. Do not fill water above the “Max.” water level mark to avoid water droplets collecting on the louvers.
WARNING:
Always ensure the water in the water tank is above the minimum (Min.) water level mark for both Continuous & Manual Water Refill. Running the unit in Cool mode with inadequate water may cause pump failure. WARNING: Do not fill the water tank with dirty water or salt water. This can damage the unit and Honeycomb media.
Note:
The water capacity refers to the total volume of water that can be contained within the air cooler water tank and water distribution system. The water capacity in the tank at the “Max.” indicator level may be lower than the actual water capacity of the air cooler.
CLEANING & DRAINING THE WATER TANK
If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide.
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect it from the power outlet
- Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty.
- Detach the water tank by unlocking the Detachable Water Tank Latches on both sides of the unit. Lift the cooler upwards away from the base and place it carefully and vertically on the floor. Be careful not to bend the water pump tubes and other parts that will hang from the bottom of the unit when the body is removed from the tank.
- Refill the water tank with clean water and drain it completely. Clean the water tank with dish detergent or a damp cloth and rinse it thoroughly.
- Refill the water tank with clean water, up to the maximum level.
- Replace the top of the air cooler carefully back onto the tank and lock the side latches. The air cooler is now ready to be used.
- Use a damp cloth to remove dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
- When the product is not in use, store the unit in a dry place out of direct sunlight
CLEANING THE CARBON DUST FILTER* AND HONEYCOMB COOLING MEDIA
- The appliance is supplied with a Carbon Dust Filter* & Honeycomb Cooling Media.
- The Carbon Dust Filter* and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance.
- Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill it with fresh water, especially if the tank has not been cleaned in a long time.
Removing the Honeycomb Cooling Media:
- Remove all the screws from the Rear Grill of the Air Cooler.
- Carefully pull out the rear grill from the cooler.
- Slide out the Carbon Dust Filter* and clean it with water.
- The Honeycomb Cooling Media is secured on the Honeycomb Frame by a Horizontal Bar that is fixed in place by two screws. Remove these two screws to release the Horizontal Bar and slide the Honeycomb out of the frame.
- Replace or clean media with water and a damp cloth as needed.
TECHNICAL SPECIFICATIONS
- Model CO48PM
- Cooling Media Honeycomb
- Product Dimensions 620 (W) x 375 (D) x 883 (H) mm
- 24.4 (W) x 14.8 (D) x 34.8 (H) in
- Net Weight 14 kg / 30.9 lbs
- Voltage 110 ~ 120V
- Frequency 60Hz
- Ampere 1.25A
- Wattage 150W
ELECTRICAL WIRING DIAGRAM
For USA Outdoor Models Only. This appliance is equipped with a GFCI plug. Press the TEST button and then the RESET button once every month to ensure proper operation.
© 2016 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. and makes no representations or warranties with respect to these products. This product is manufactured by Airtek Int’l Corp. Ltd. (a subsidiary of JMATEK Ltd.)