Panasonic-CS-XU9ZKH-8-Air-Conditioner-FEATURE

Panasonic CS-XU9ZKH-8 Air Conditioner Operating Instructions

Panasonic-logo

Panasonic CS-XU9ZKH-8 Air Conditioner Operating Instructions

Panasonic-CS-XU9ZKH-8-Air-Conditioner-IMG

Quick Guide

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig1

Accessories

  • Remote control
  • AAA or R03 batteries × 2
  • Remote control holder
  • Screws for remote control holder × 2

Basic operation

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig2

How to Use

Indicators

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig3

To adjust airflow direction

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig4

  • Do not adjust the flap by hand.
  • For details operation, refer “To Learn More….”
To adjust FAN SPEED and QUIET condition

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig5

FAN SPEED:

  • When FAN AUTO is selected, the fan speed is adjusted automatically according to the operation mode.
  • Select the lowest fan speed Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig6 to have a low noise operation.
  • When iAUTO-X mode is selected, the fan speed is automatically set to AUTO. To adjust the fan speed, cancel iAUTO-X mode.

QUIET:

  • This operation reduces airfl ow noise.
To enjoy fresher and cleaner environment

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig7

  • This operation combines both nanoe™X and nanoe™-G (nanoe™ TECHNOLOGY).
  • nanoe™ TECHNOLOGY automatically starts when the unit is turned on.
  • Press Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig8to turn ON or OFF this operation manually.
  • This operation can be activated even when the unit is OFF. Note that the flap and fan speed will operate according to the remote control setting.
  • If a power failure occurs during this operation, this operation resumes immediately when power resumes.
To reduce power consumption

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig9

  • To reduce power consumption for better energy saving without sacrificing comfort.
  • ECO function cannot be activated during iAUTO-X mode.
  • Press the button again to cancel.
To reach the desired temperature quickly

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig10

  • When iAUTO-X mode is turned on, the unit automatically reduces the temperature by 2°C (4°F) from the set temperature to accelerate the room cooling effect.
  • Fan speed is set to AUTO and you cannot change the fan speed.
  • After a maximum of 4 hours, the unit returns to the last set temperature. To extend iAUTO-X operation, press Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig11again to reactivate the iAUTO-X.
  • When the room has reached set temperature, and room temperature is > 23°C and room humidity is > 60%, iAUTO-X will operate at a predetermined setting.
  • When room humidity is high, fan speed will operate at lower speed.
  • When the unit is OFF and you want to reach the desired temperature quickly, pressPanasonic-CS-XU9ZKH-8-Air-Conditioner-Fig11 to turn on the unit in iAUTO-X mode.
  • To cancel iAUTO-X mode, press Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig12button.
To maximize comfort while sleeping

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig13

  • This operation provides you with a comfortable environment while sleeping. It will automatically adjust the sleep pattern temperature during the activation period.
  • The indoor unit indicator will dim when this operation is activated. This is not applicable if the indicator brightness has been manually dimmed.
  • This operation is incorporated with the activation timer (0.5, 1, 2, 3, 4, 5, 6, 7, 8 or 9 hours).
  • This operation can be set together with timer. Sleep operation has the priority over OFF timer.
  • This operation can be cancelled by pressing the respective button until the sleep timer reaches 0.0h.
To connect to a network

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig14

  • For Wireless LAN Module operation setup, please refer to Setup Instructions Manual.

How to Use

To set the timer

You can set the timer to turn on and off the unit at 2 different preset time.

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig15

  • To cancel the timer, press Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig16or Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig17to select the respective setting Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig20orPanasonic-CS-XU9ZKH-8-Air-Conditioner-Fig20 , then pressPanasonic-CS-XU9ZKH-8-Air-Conditioner-Fig18.
  • If the timer has been cancelled manually or due to power failure, you can restore the timer again. Press Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig16or Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig17to select the respective setting Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig20orPanasonic-CS-XU9ZKH-8-Air-Conditioner-Fig20 , then press Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig19
  • The nearest timer setting is displayed and will activate in sequence.
  • The timer operation follows the clock setting on the remote control and will repeat daily when timer has been set. For clock setting, refer to Quick Guide.

Note

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig21

To Learn More

Operation mode

iAUTO-X : Provides fast cooling operation which is ideal on a hot day.
COOL : Provides effi cient comfort cooling to suit your needs.
DRY : Operates at low fan speed for a gentle cooling operation. When FAN AUTO is selected, DRY mode will operate with humidity control.

Energy saving temperature setting

You may save energy when operating the unit within the recommended temperature range. COOL: 26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.

Air flow direction

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig22In iAUTO-X mode:

The horizontal flap swings up/down automatically at a predetermined position. Once the temperature is achieved, the horizontal flap is fixed at upper position.

In COOL mode:
The horizontal flap is fixed at middle position setting. Once the temperature is achieved, the horizontal flap swings up/down automatically.

In DRY mode with Humidity Control:
If FAN AUTO is set, the horizontal flap swings up/down automatically. Once the temperature is achieved, the horizontal flap is fixed at the predetermined position.

In DRY mode without Humidity Control: The horizontal flap is fixed at middle position setting. Once the temperature is achieved, the horizontal flap swings up/down automatically.

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig22In iAUTO-X/COOL/DRY mode:
The horizontal flap swings up/down automatically.

Auto restart control
  • When power is resumed after a power failure, the operation will restart automatically with the last operation mode and airflow direction.
  • This control is not applicable when TIMER is set.
Inside Cleaning

This function is to enhance the inside cleaning of the air conditioner indoor unit. To activate inside cleaning, turn off the unit and press Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig8button for more than 3 seconds from remote control. During inside cleaning operation, nanoe™X will turn on and horizontal flap is open with low fan speed operation for a maximum of 2.5 hours before the unit is turned off. Do not turn off the power supply during this operation. The inside cleaning operation is completed when the fan stops and the flap is close. When power is resume after failure, this operation will not resume.

Operating conditions

Use this air conditioner in the temperature range indicated in the table.

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig23

Cleaning the Air Conditioner

Cleaning has to be carried out at regular intervals to ensure the unit is at optimal performance. A dirty unit may cause malfunction and you may retrieve “H 99” error code. Consult an authorized dealer.

  • Before cleaning, switch off the power supply and unplug the unit.
  • Do not touch the aluminum fi n as the sharp parts may cause injury.
  • Do not use benzine, thinner or scouring powder.
  • Use soap ( pH 7) or neutral household detergent only.
  • Do not use water hotter than 40 °C / 104 °F.
Indoor unit ( Structure of the unit may vary depending on the model)

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig24

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig25

Troubleshooting

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig26

 

When..

The remote control is missing or a malfunction has occurred

  • Raise the front panel.
  • Press AUTO OFF/ON once to use in iAUTO-X mode.
  • To operate forced COOL mode, press AUTO OFF/ON hold until you hear 1 beep, then release. (This operation shall be performed by service personnel)
  • Press AUTO OFF/ON again to turn off the unit.

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig27

  • The indicators are too bright
  • To dim or restore the indicators’ brightness on the unit, press Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig28on the remote for 5 seconds.
  • Conducting a seasonal inspection after extended period of non-use
  • Check the batteries.
  • Check that there is no obstruction around the air inlets and outlet vents.
  • Use AUTO OFF/ON on the unit to select COOL mode. For details, refer “The remote control is missing or a malfunction has occurred” above. After 15 minutes of operation, it is normal to have the following temperature difference between the air inlet and outlet vents:
    COOL: ≥ 8 °C / 14.4 °F
  • The units will be not used for an extended period
  • Activate nanoe™ TECHNOLOGY mode for 2~3 hours to remove any moisture left in the internal parts thoroughly. This is to prevent mold growth.
  • Turn off the power supply and unplug the unit.
  • Remove the batteries from the remote control.

NON SERVICEABLE CRITERIAS

TURN OFF THE POWER SUPPLY AND UNPLUG THE UNIT. Then consult an authorized dealer in the following conditions:

  • Abnormal noise during operation.
  • Water/foreign particles have entered the remote control.
  • Water is leaking from the indoor unit.
  • The circuit breaker switches off frequently.
  • The power cord becomes unnaturally warm.
  • The switches or buttons are not functioning properly.
How to retrieve error codes

If the unit stops and the TIMER indicator blinks, use the remote control to retrieve the error code.

Panasonic-CS-XU9ZKH-8-Air-Conditioner-Fig29

REFERENCE LINK

https://www.panasonic.com/vn/en/air-solutions/air-conditioning/residential/cooling-only-air-conditioners/aero-elite-inverter.html

Leave a Reply