Campbell Hausfeld DC060500 Compressor Manual
BEFORE YOU BEGIN
Description
Thank you for purchasing this Campbell Haus Feld quiet, soilless compressor. For over 100 years, we have manufactured products that are durable, reliable, and just easy to use and maintain. Portable soilless air compressors are for home and workshop use. Cleaning or replacement of the inlet filter on all models and draining moisture from the air receivers are required maintenance.
UNPACKING
Do not lift or move the unit without appropriately rated equipment. Be sure the unit is securely attached to the lifting device used. Do not lift the unit by holding onto tubes or coolers. Do not use a unit to lift other attached equipment. After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing, or damaged parts.
Check to be sure all supplied accessories are enclosed with the unit. In case of questions, or damaged or missing parts, please visit www.campbellhausfeld.com for customer assistance. assistance. Do not operate the unit if damaged during shipping, handling, or use. Damage may result in bursting and cause injury or property damage.
GENERAL SAFETY INSTRUCTIONS
Overview of Safety Warning System and Your Responsibilities READ THIS MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THE INSTRUCTIONS AND SAFETY PRECAUTIONS IN THIS MANUAL CAN RESULT IN SERIOUS INJURY OR DEATH. KEEP THIS MANUAL FOR FUTURE REFERENCE. Your safety and the safety of others depend on you thoroughly reading and understanding this manual. If you have questions or do not understand the information presented in this manual, please visit www.campbellhausfeld.com.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. The meaning of this safety alert symbol is as follows: Attention! Become Alert! Your Safety may be at Risk. The message that appears next to the warning can be either written or pictorially presented. Operations that may cause product damage are identified by the signal word “NOTICE” in this manual.
Important Safety Information
Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. This manual contains important safety, operational, and maintenance information. If you have any questions, please visit www.campbellhausfeld.com for customer assistance. Since the air compressor and other components (material pump, spray guns, filters, lubricators, hoses, etc.) used make up a high-pressure pumping system, the following safety precautions must be observed at all times:
- Read all manuals included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment.
- Follow all local electrical and safety codes as well as the United States National Electrical Codes (NEC) and Occupational Safety and Health Act (OSHA).
- Only persons well acquainted with these rules of safe operation should be allowed to use the compressor.
- Keep visitors away and NEVER allow children in the work area.
- Wear safety glasses and use hearing protection when operating the unit.
- Do not stand on or use the unit as a handhold.
- Before each use, inspect the compressed air system and electrical components for signs of damage, deterioration, weakness, or leakage. Repair or replace defective items before using.
- Check all fasteners at frequent intervals for proper tightness.
SPECIFICATIONS
- Motor HP 1.0
- Tank Capacity 6 gallon
- Phase Single
- Number of Cylinders 2
- Air Delivery @ 90 psi 2.4 SCFM
- Voltage 110 – 120
- Amperes 7
- Hertz (Cycles) 60
- Maximum Pressure 125 psi
- RPM 1750
- Tank Outlet Size 1/4 in. IM Quick Connect
- Unit Weight 55.03 pounds.
OPERATING INSTRUCTIONS
Recommended Break-In Period
The compressor should be run continuously at 90 PSI or lower for one hour to allow proper seating of the piston rings.
- Open the drain completely and run the compressor for 60 minutes.
- Turn off the compressor and close the drain. The compressor is now ready for use.
If the compressor is run under humid conditions for short periods of time, the humidity will condense in the crankcase and cause the oil to look creamy. Oil contaminated by condensed water will not provide adequate lubrication and must be changed immediately. Using contaminated oil will damage bearings, pistons, cylinders, and rings and is not covered under warranty.
To avoid water condensation in the oil, periodically run the compressor with tank pressure near 120 psi for single-stage compressors by opening the drain valve or an air valve connected to the tank or hose. Run the pump for an hour at a time at least once a week or more often if the condensation reoccurs.
IMPORTANT: Change oil after the first 50 hours of operation and every 200 hours afterward.
REFERENCE LINK