You are currently viewing Crane EE-5069 Air Purifier with True HEPA Filter User Manual

Crane EE-5069 Air Purifier with True HEPA Filter User Manual

Crane logo

Crane EE-5069 Air Purifier with True HEPA Filter User Manual

Crane-EE-5069-Air-Purifier-with-True-HEPA-Filter-User-Manual-prduct-ig

CRANE & SUSTAINABILITY
Crane USA is dedicated to your environment both inside and outside your home. We know if cleaned and maintained properly, our products last for years helping to reduce unnecessary use of resources and emissions making new products. The Crane manual you are holding is from recycled materials with no added finishes or harmful dyes. If the humidifier should no longer operate, please be sure to dispose of the unit in an environmentally friendly way by taking it to a public collection point.

IMPORTANT SAFETY INSTRUCTIONS

WARNING! READ AND SAVE THESE INSTRUCTIONS.
Failure to follow all the instructions listed below may result in electric shock, fire, and/or serious personal injury.

  1. It is advisable to carry a humidifier with two hands.
  2. DO NOT operate outdoors. This humidifier is intended for indoor use only.
  3. Always have water in the Water Tank when operating the unit.
  4. Use only clean, cool tap water to fill the Humidifier body (filtered or distilled water is recommended to avoid white dust if tap water is too hard. DO NOT use hot water.
  5. Always have the Top Cover and Mist Lid in place while the unit is operating. Place the humidifier so the mist aims away from children, walls, furniture, and electrical appliances.
  6. Use only a 110-120VAC outlet. * ALWAYS plug and unplug the unit with dry hands to avoid electric shock.
  7. Never operate the unit with a damaged cord or plug.
  8. Always place the unit on a smooth, flat, lint-free, non-metallic, waterproof, and level surface and position the unit away from direct sunlight. Keep the cord away from heated surfaces and areas where it could be walked on or tripped over. Unplug the unit when not in use and whenever you clean or move the unit.
  9. Do not add medication of any type to this humidifier. Do not cover any openings on the unit or insert objects into any openings.
  10. The unit should not be left unattended in a closed room as the air could become saturated and leave condensation on walls or furniture. Leave the room door partly open when the humidifier is being operated.
GENERAL SAFETY INSTRUCTIONS

CAUTION:
A short Power Supply Cord is provided to reduce the risk of personal injury resulting from becoming entangled in or tripping over a longer cord. Extension cords are available from local hardware stores and may be used if care is exercised in their use. If an extension cord is required, special care and caution is necessary. Also, the extension cord must be (1) marked with an electrical rating of 125 V and at least 13 A., 1625 W., and (2) the cord must be arranged so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over

POLARIZED PLUG
This humidifier has a polarized plug (one blade is wider than the other). As a safety feature to reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.

SAFETY WARNING

Although your humidifier is easy to operate, for your safety, the below warnings must be. followed:

  1. Do not place the humidifier near a heat source.
  2. Never leave the humidifier unattended while connected to the electrical outlet.
  3. To avoid any accidents, never cover the Mist Lid when the humidifier is in operation.
  4. Use the humidifier on a smooth, flat, lint-free, non-metallic, waterproof, and level surface away from water.
  5. Do not unplug from the wall socket by pulling on the supply cord.
  6. The humidifier must be unplugged:
    • A. Before either filling or emptying the humidifier.
    • B. Before any cleaning or maintenance is performed.
    • C. After each use.
    • D. If it appears to be faulty

LIST OF MAIN PARTS

Crane-EE-5069-Air-Purifier-with-True-HEPA-Filter-User-Manual-fig-1

TECHNICAL SPECIFICATIONS

Rating Voltage120 V 60 Hz
Power Supply33 W
UVC Bulb3 W
Weight7.7 lbs. (including the filter)

AIR PURIFIER FILTERS:

Level 1: Particle Filter

The purpose of this filter is to capture initial dust and allergen particles. It helps extend the life of the HEPA filter by removing large particles before they can get to the HEPA filter. You will find visible dust, hair, and lint in the particle filter.

NOTE: See Maintenance instruction for the Particle Filter.

 

 

 

 

 

 

 

 

 

Crane-EE-5069-Air-Purifier-with-True-HEPA-Filter-User-Manual-fig-2

 

Level 2: HEPA Filter

HEPA stands for High Efficiency Particulate Air. The inlet grill of your air purifier draws in dirty air. Crane’s air purifier true HEPA filter removes at least 99.97% of all particles as small as 0.3 microns. Microns are used to measure the size of these microscopic airborne particles.

 

Allergens such as pollen, smoke, animal dander, mold spores, and dust get trapped in the HEPA filter.

Level 3: Activated Carbon Filter

The activated carbon filter helps absorb common household odors caused from tobacco, pets, garbage, and cooking

Level 4: UV Bulb

The ultraviolet bulb helps reduce germs from growing in the HEPA filter.

NOTE: Blue UV Indicator Light indicates that the UV Bulb is ON unless the unit is set to Sleep Mode.

Crane-EE-5069-Air-Purifier-with-True-HEPA-Filter-User-Manual-fig-3
BEFORE USE
  1. Remove the plastic from the filter before the first use.
  2. Select a firm, level & flat surface to place the purifier. For proper airflow, locate the unit at least 3 feet from any wall or furniture.
  3. Do not place the air purifier near electronic devices that are sensitive to electrical fields.
  4. Do not place the unit on metal shelving. Air purifiers may be placed on the floor, nightstand, table, or desk. Make sure the outlet grill faces away from the nearest wall or furniture.
  5. Make sure the intake and outlet grills are not blocked
  6. Plug into a grounded 120V outlet. (See Safety Instructions)

OPERATION & USE

OPERATING INSTRUCTIONS:

  1. Power Button: Press to turn on and off the air purifier.
  2. Fan Speed Button: Press to select speeds of I, II, III, or Turbo (Low, Medium, High, and Turbo) All lights will illuminate on the Turbo setting.
  3. NOTE: The Air Purifier will start on Medium Speed when first powered on
    1 Press: High 3 Press: Low
    2 Press: Turbo 4 Press: Medium
  4. UV/Sleep Button: Press to control UV Bulb and Sleep Mode. Press once to turn on the UV bulb, press twice for Sleep Mode, and press three times to turn the UV bulb off. Press four times to deactivate Sleep Mode. In Sleep Mode, the light blinks 10 times and all indicator lights will go off. When the air purifier goes into sleep mode, the fan setting automatically defaults to Low. To deactivate the sleep mode press any button on the control panel. NOTE: Once the item is unplugged the sleep mode needs to be reset
  5. Timer Button: Press to operate the unit in intervals of 2 hours, 4 hours, and 8 hours. Press once for 2 hours, twice for 4 hours, and three times for 8 hours. The unit will turn off when the scheduled operating time has elapsed. To go back to a continuous run time, press the button until there are no more indicator lights lit up.
  6. Auto/Light Button: Press to control Auto Mode and Air Quality Indicator Light. In Auto Mode, the purifier will automatically adjust based on the air quality in the room.
REPLACING THE HEPA FILTER

When the Filter Reset light is illuminated, it is an indication to replace the filter. Once you have replaced the filter, hold the POWER button down for 5 seconds until the unit beeps to reset the system. On average, the HEPA Filter needs to be replaced every 3-6 months. Filter life will depend on air quality and usage.

  1. ALWAYS turn off and unplug the air purifier from the power outlet before replacing the filter. 2. Unlock the base cover by sliding the base lock and lifting the top from the base.
  2. Discard the old HEPA filter. DO NOT attempt to wash the HEPA filter.
  3. Insert the new filter into the unit.
  4. Once you have replaced the filter, replace the top onto the base and re-lock the base cover. Hold the POWER button down for 5 seconds until it beeps, to reset the filter indicator.

NOTE:
Replacement HEPA Filter HS-1943 can be purchased online at www.craneusa.com.

REPLACING THE UV BULB

WARNING
Always make sure that the air purifier is turned OFF and UNPLUGGED from the power outlet before replacing UV bulb. Always use caution when handling the UV bulb to prevent accidental breaking of the bulb. NEVER touch the glass part of the bulb. Oil from fingers will reduce the performance of the UV bulb. Always use gloves or handle the bulb only by the metal area on the bulb. Failure to do so may risk shock, fire hazard, or damage to the unit and replacement lamp.

DO NOT use a vacuum to pick up broken bulb glass or handle broken bulb with your hands. Sweep debris into a plastic bag and dispose properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of old bulb(s). The UV bulb is designed to provide approximately one year of continuous operation. After one year the UV bulb’s effectiveness is greatly reduced. For maximum protection, replace after a year or if the blue UV bulb does not illuminate when the UV switch is ON.

Crane-EE-5069-Air-Purifier-with-True-HEPA-Filter-User-Manual-fig-6

Crane-EE-5069-Air-Purifier-with-True-HEPA-Filter-User-Manual-fig-7

  1. Unplug the unit and turn it upside down. Remove the base and filter.
  2. Slowly loosen the SINGLE SILVER screw.
  3. Twist off the bulb’s protective casing counterclockwise and pull it off to reveal the UV light bulb
  4. Grasp the wire connectors just under the bulb housing and gently disconnect it by squeezing the side and top notches.
  5. Holding the bulb housing straight up SLOWLY slide the UV bulb out of the housing to keep rubber protectors in place. SLOWLY slide the new bulb into the housing to fit into the top and bottom rubber protectors. DO NOT FORCE. 6. Grasp the wire connectors from the purifier and bulb housing and reconnect them by pushing them together.
  6. Re-attach the bulb housing by first twisting clockwise back onto the unit and then tightening the SILVER screw.
  7. Insert the filter and reattach the base cover

MAINTENANCE

CAUTION:
Always be sure the air purifier is unplugged and switched off before cleaning, removing filters or attempting to store the item. NEVER PLUG OR UNPLUG THE AIR PURIFIER WITH WET HANDS.

CLEANING THE AIR PURIFIER
NOTE: No part of the air purifier should be placed in the dishwasher.

  • Always unplug the unit before cleaning.
  • Once unplugged, the exterior of the unit may be cleaned by wiping with a lightly damp cloth.
  • DO NOT ALLOW WATER TO GET INTO THE INTAKE AND OUTLET GRILLS.
  • DO NOT USE GASOLINE, POLISH, OR ANY CHEMICAL SOLUTION TO CLEAN AIR PURIFIER.
  • The intake grill and outlet grill can be cleaned of dust with a small soft brush.
  • If you wish to lightly clean the inside of the air purifier, please remove filters and ONLY use a dry, soft cloth to lightly wipe down.

RECALIBRATING THE AIR QUALITY SENSOR
In the event that the unit indicates a continuous air quality indicator (blue, orange, yellow, red) without changing based on the air quality, you may need to test the air quality sensor to determine if the sensor needs to be recalibrated.

TO RECALIBRATE THE AIR QUALITY SENSOR:

  1. While the air purifier is turned on, place the air purifier in a large plastic bag.
  2. Press and hold the TIMER button, wait until you hear the 2nd Beep, and remove your finger from the timer button.
  3. Close up the plastic bag completely around the unit.
  4. Wait 3-5 minutes for the sensor to recalibrate. The air quality indicator light will turn blue.
  5. Remove the unit from the plastic bag and resume normal use of the unit.

STORING YOUR PURIFIER
Store the air purifier is a dry location. Do not place heavy items on top of the air purifier during storage as this may result in possible damage of the appliance. Store the cord in a clean, dry location away from metal objects. Always check the plug before use to assure metal items have not become attached.

TROUBLESHOOTING

DO NOT attempt to repair the air purifier yourself. If the air purifier continues to not operate, please contact Crane Customer Care.

ProblemSolution
 

 

 

 

If the air purifier does not operate:

§ Make sure the base cover is locked into place. Ensure the base is locked into the unit. There is an automatic safety shut off switch if the base cover is not shut completely or the bulb housing was not replaced correctly.

§ Make sure the air purifier is at I, II, III or Turbo.

§ Make sure the power cord is plugged into a working power outlet.

§ If the above solutions do not work, please contact Crane Customer Care.

 

 

If the airflow is reduced

§ Make sure that the intake and outlet grills are not blocked and are free of debris.

§ Check your HEPA filter, it may need to be replaced.

§ If the above solutions do not work, please contact Crane Customer Care

 

 

 

If blue UV indicator light does not illuminate:

§ Check that the UV bulb is illuminated by placing the air purifier in a dark room and if a faint blue illumination is not visible from the grills, the UV bulb may be burned out. Please refer to UV Bulb Replacement in this instruction manual.

§ Check to see if the fan is running. The UV bulb will not illuminate unless the fan is on.

§ If the above solutions do not work, please contact Crane Customer Care.

 

 

Air Quality Indicator Light not working:

 

§ Recalibrate the Air Quality Sensor by following the steps listed on page 8.

§ If recalibration does not resolve the issue, contact Crane Customer Service.

CRANE WARRANTY

For more information regarding the warranty policy, please visit our website: www.crane-usa.com/customer-service L I M I T E D W A R R A N T Y Thank you for purchasing a Crane product that has been tested to meet our stringent quality standards. This product is warrantied to be free from manufacturing defects under normal use and conditions for 1 year.

THE WARRANTY REQUIRES A DATED PROOF OF PURCHASE.
This warranty is void if the defect is due to accidental damage, misuse, abuse, neglect, improper repair or alteration by unauthorized persons, or a failure to follow operating instructions provided with the product. This warranty does not apply to normal wear and tear or commercial use. In no event shall liability exceed the purchase price paid by the purchaser of the product.

Under no circumstances shall there be liability for any loss – direct, indirect or incidental – or consequential damage arising out of, or in connection with the use of this product. This warranty is valid only in the 48 contiguous states plus the District of Columbia and excludes Puerto Rico and the Virgin Islands.

This warranty is effective only if the product is purchased and operated in the United States of America. Any instructions or warranty included in this manual may be subject to change without notice. For the most up-to-date instructions and warranty information, please contact us or visit our website.