Crane EE-6913 Top Fill Warm Cool Mist Ultrasonic Humidifier User Manual
IMPORTANT SAFETY INSTRUCTIONS
- DO NOT operate outdoors. This humidifier is intended for indoor use only.
- KEEP OUT OF REACH OF CHILDREN.
- Use only clean, cool tap water to fill the Humidifier body (filtered or distilled water is recommended to avoid white dust if tap water is too hard). DO NOT use hot water.
- Always have the Top Cover and Mist Lid in place while the unit is operating. Place the humidifier so the mist aims away from children, walls, furniture and electrical appliances.
- Use only a 120V outlet. Do not unplug from the wall socket by pulling on the supply cord.
- Never operate the unit with a damaged cord or plug.
- Do not add medication of any type into this humidifier. Do not cover any openings on the unit or insert objects into any openings.
- The unit should not be left unattended in a closed room as the air could become saturated and leave condensation on walls or furniture. Leave room door partly open when humidifier is being operated.
- When cleaning the inside of the humidifier, keep water away from the Fan Vent. Turn off and unplug the humidifier to wipe the exterior (except the electrical controls) with a damp cloth.
GENERAL SAFETY INSTRUCTIONS
WARNING! Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire or serious personal injury. The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the user that common sense and caution are a factor which cannot be built into this product and must be supplied by the user.
LIST OF MAIN PARTS
- Cover
- Mist Lid
- Removable Water Tank (inside base)
- Base
- Control Panel
- Aroma Tray (on bottom side)
- Handle
- Mist Chamber
- Mist Chamber Cap
- Ceramic Filter
- Nebulizer
- Fan Vent
- Float
TECHNICAL SPECIFICATIONS
Rating Voltage | 120V |
Wattage | 110W |
Frequency | 60Hz |
Water Tank Capacity | 1.2 Gallon |
Run Time Per Tank | Up to 24 hours |
Noise Level | < 35 dB(A) |
Humidifying Capacity | Up to 500 Sq. Ft. |
BEFORE EACH USE:
CHECK HUMIDIFIER PLACEMENT:
Place the Humidifier on an elevated, non-metallic, lint-free, waterproof, level surface at least 2 feet above the floor.
- DO NOT PLACE ON CARPET OR TOWEL. The fan vent is located on the back of the humidifier base. The fan vent MUST NOT be obstructed.
- DO NOT PLACE ON WOOD SURFACE or near furniture that can be damaged by too much moisture.
A NOTE ABOUT HUMIDITY
- To reduce excessive humidity or condensation, especially in small rooms, leave the room door open and adjust mist intensity to the low output setting.
- Too much humidity in the room may allow moisture to accumulate on surfaces where bacteria and fungi can grow. Moisture that gathers may also damage furniture and walls, especially wallpaper.
- Ideal relative humidity level is between 45% and 65%.
ASSEMBLY & USE
BEFORE FIRST USE:
- Remove the top cover from the main body, fill water into water tank directly. Do NOT exceed the MAX level mark. ONLY FILL WATER INTO REMOVABLE WATER TANK
- Ensure Mist Chamber Cap is attached to the top of the mist Chamber in the water tank.
- Place top cover on humidifier base, making sure it fits together securely.
- Plug the power cord into a wall socket and turn on the unit by using the Control Panel.
- Touch the POWER icon to turn the unit on. Use the digital control panel or the remote control to adjust the mist output intensity or to use the other features (see page 6).
- When the humidifier runs out of water, the humidifier will beep 3 times and the unit will stop working. will appear on the display panel. Refill the water tank and turn on the humidifier.
AROMA TRAY
To use the aroma tray: Press in on the tray to open and remove tray, add essential oils to the included pad (or with any compatible scent pad) as desired and replace tray before running humidifier۔
Replacing the Battery
- Remove the battery compartment by pinching the tab and pulling the compartment out as below picture.
- Remove the old battery.
- Replace with a new CR2025 battery. Make sure that the polarities match. Replace the battery compartment.
MAINTENANCE
Cleaning and disinfecting on a regular basis is important for maintaining the performance of your humidifier.
IMPORTANT: Hard water and water left in the tank or base when not in use may result in buildup of mineral deposits and bacteria which may inhibit the output efficiency as well as void the warranty. If water remains in the Water Tank and Base for more than a day or two, bacterial growth is possible.
DAILY MAINTENANCE
- Turn off, unplug from outlet, remove top and water tank, empty water from water tank and base daily. When emptying the humidifier be sure to pour away from the fan outlet.
- Empty water tank and rinse with water.
- Allow top, water tank & base to air dry.
- Leave top off the base until ready for next use.
WEEKLY MAINTENANCE
- Turn off, unplug from the outlet, remove top and water tank from base.
- Fill water tank halfway with clean water, add 2-4 tablespoons of white vinegar and let sit for 20 minutes. Empty water tank and rinse with clean water.
- Fill Base with 1 and a half cups of water, add 1 tablespoon of white vinegar and let sit for 20 minutes. Empty base and rinse with clean water. Be sure to empty water in the base away from the fan vent.
- Wash the top and mist lid with a white vinegar and water solution by wiping each piece and rinsing with clean water.
TO CLEAN THE CERAMIC FILTER
Clean and activate the ceramic ball filter after every 30 fills of the water tank in the humidifier or when the ceramic ball is dirty.
- Unscrew the filter from the water tank.
- Submerge the ceramic filter in white vinegar for 5 minutes.
- Rinse the ceramic filter thoroughly with clean water.
- Allow filter to air dry for 4-6 hours.
STORING YOUR HUMIDIFIER
- Turn off, unplug from outlet, and empty water from top & base.
- Follow instructions for weekly maintenance above.
- Let all parts dry completely.
- Store humidifier in a cool, dry place.
TROUBLESHOOTING
Problem | Solution |
No mist being Produced: |
|
Humidifier Does Not Have Any Power: |
|
There is a Strange Odor: |
|
Air Blows, but No Mist Produced: |
|
White Dust Appears & Settles Outside the Humidifier: |
|
No Warm Mist: |
|
Incorrect Humidity Level Displayed: |
|
Mist Coming Out at the Base or Top: |
|
Error Code – E1 | Follow the steps to reset: Reset process must be completed within 1 minute after humidifier is plugged in (step 2).
|
Error Code – EF |
|