INTRODUCTION

Thank you for bringing Frigidaire into your home! We see your purchase as the beginning of a long relationship together. This manual is your resource for the use and care of your product. Please read it before using your appliance. Keep it handy for quick reference. If something doesn’t seem right, the troubleshooting section will help you with common issues. FAQs, helpful tips and videos, cleaning products, and kitchen and home accessories are available at www.frigidaire.com. We are here for you! Visit our website, chat with an agent, or call us if you need help. We may be able to help you avoid a service visit. If you do need service, we can get that started for you.

IMPORTANT SAFETY INSTRUCTIONS

WARNING

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:

  • Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet.
  • If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first.
  • Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or reinstalling this unit.

Electrical Information

  • The complete electrical rating of your new portable air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.
  • Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
  • Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
  • Do not run air conditioner without outside protective cover in place. This could result in mechanical damage within the air conditioner.
  • Do not use an extension cord or anadapter plug.
  • Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig1

NOTE: The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section ‘Operation of  Current Device’ for details. In the event that the power supply cord is damaged, it cannot be repaired. It must be replaced with a cord from the product manufacturer.

SAFETY PRECAUTIONS

DANGER! Avoid Serious Injury or Death

  • This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
  • Do not insert or place fingers or objects into the air discharge area in the front of the unit.
  • Do not start or stop the air conditioner by unplugging the power cord or turning o the power at the electrical box.
  • Do not cut or damage the power cord.
  • If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
  • In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized Electrolux servicer.
  • Do not operate the air conditioner with wet hands.
  • Do not pull on the power cord.
  • Do not drink any water that is drained from the air conditioner.
  • This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The appliance shall be installed in accordance with national wiring regulations.

CAUTION! Avoid Injury or damage to the unit or other property

  • Provide ventilation per installation instructions.
  • Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively.
  • Do not climb on or place objects on the unit.
  • Do not hang objects off the unit.
  • Do not place containers with liquids on the unit.
  • Turn off the air conditioner at the power source when it will not be used for an extended period of time.
  • Periodically check the condition of the unit’s installation accessories for any damage.
  • Do not apply heavy pressure to the radiator fins of the unit.
  • Operate the unit with air filter in place.
  • Do not block or cover the intake grille, discharge area and outlet ports.
  • Ensure that any electrical/electronic equipment is one yard away from the unit.
  • Do not use or store flammable gases near the unit.
  • Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
  • Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
  • When cleaning the unit, first make sure that the power and circuit breaker are turned off.

WARNING

FOR FLAMMABLE REFRIGERANT

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • Do not pierce or burn.
  • Be aware that the refrigerants may not contain an odor.
  • Compliance with national gas regulations shall be observed.
  • Keep ventilation openings clear of obstruction.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance) and ignition sources or (for example: an operating electric heater) close to the appliance.
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate  an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
  • DO NOT modify the length of the power cord or use an extension cord to power the unit.
  • Flammable refrigerant – R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.
  • The refrigerating system should not receive maintenance, service, or repair by any person.
  • Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
  • Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.

NOTE Examples of leak detection fluids are – bubble method, – fluorescent method agents. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found contact local manufacture to replace unit.

  • Do not use this device to turn the unit on or off.
  • Always make sure the RESET button is pushed in for correct operation.
  • The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.
  • If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained from the product manufacturer.

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Unit must be upright for one hour prior to operating. The unit should be operated in a temperature range of 60°F – 95°F (16°C – 35°C). Performance may be reduced outside of these operating temperatures.

Operation of Current Device

The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:

  • Plug in the Air Conditioner.
  • The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
  • Press the RESET button. Again you will notice a click as the button engages.
  • The power supply cord is now supplying electricity to the unit. (This is also indicated by a light on the plug head). Plug in & press RESET

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig2

Normal Sounds

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig1

  1. High pitched Chatter
    Today’s high efficiency compressors may have a high pitched chatter during the cooling cycle.
  2. Sound of Rushing Air
    At the top of the unit, you may hear the sound of rushing air being moved by the fan.
  3. Gurgle/Hiss
    “Gurgling or hissing” noise may be heard due to refrigerant passing through evaporator during normal operation.
  4. Vibration
    Unit may vibrate and make noise because of uneven floor.

FCC STATEMENT

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the device and receiver.
  • Connect the equipment into an outlet other than the one used for the receiver.
  • Consult the dealer or an experienced radio/TV technician for assistance.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • This device must accept any interference received, including interference that may cause undesired operation.

FCC CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

RF exposure statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum 20 cm between the radiator and your body. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig2

UNIT DESCRIPTION

Explanation of symbols displayed on the unit

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig4

Unit Description

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig3

ACCESSORIES INCLUDED & INSTALLATION INSTRUCTIONS

Accessories Included

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig4

Installation Instructions

EXHAUSTING HOT AIR

In the Cool Mode the appliance must be placed close to a window or opening so that the warm exhaust air can be ducted outside. First position the unit on a flat surface, and make sure it is within the vicinity of a single circuit outlet power source. Make sure there’s a minimum of 31.5″ clearance in the front/back of the unit, and a minimum of 19.7″ clearance in the left/right sides of the unit.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig5

INSTALLATION INSTRUCTIONS

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig6

The hose can be extended from its original length of 15″ up to 59″, but try to maintain the minimum required length. Also make sure that the hose does not have any sharp bends or sags.(Fig.5)

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig7

Installation in a double-hung sash window

  • Cut the adhesive foam seals (A) to the proper lengths and attach them to the window and sill.(Fig.6)

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig8

  • Open the window sash and place the window slider kit on the window sill (Fig.7).
  • Attach the window slider kit to the window sill. Adjust the length of the window slider kit according to the width of window. Screw down the two screws on the window slider kit. See Fig.7.
  • Cut the adjustable window slider kit if the width of window is less than 26.6 inches(Fig.8).

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig9

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig9

  • Close the window sash securely against the window slider kit.(Fig.9)
  • Drive two 1/2″ screws to secure the window slider kit to the window sash.(Fig.9)
  • Secure the window slider kit to the window sill(Fig.9):
  • For wooden window: Use 3/4″ screws for securing.
  • For Vinyl-Clad windows: Use 1/2″ hex head cap screws for securing.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig11

  • To secure lower sash in place, attach right angle sash lock with 1/2″ (12.7mm) screw as shown(Fig.10).

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig12

  • Cut the non-adhesive foam seal (B) to an appropriate length and seal the open gap between the top window sash and outer window sash, as shown in Fig.11.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig12

Installation in a sliding sash window

  • Cut the adhesive foam seals (A) to the proper lengths and attach them to the window frame. See Fig.12.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig14

  • Open the window sash and place the window slider kit on the window sill (Fig.13).
  • Attach the window slider kit to the window sill. Adjust the length of the window slider kit according to the height of window.
  • Screw down the two screws on the window slider kit. See Fig.13.
  • Cut the adjustable window slider kit if the height of window is less than 26.6 inches(Fig.8).

  • Close the window sash securely against the window slider kit.(Fig.14)
  • Drive two 1/2″ screws to secure the window slider kit to the window sash.(Fig.14)
  • Drive two 3/4″ screws to secure the window slider kit to the window sill.(Fig.14)

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig16

  • Cut the foam seal B to an appropriate length and seal the open gap between the sliding sash and outer window sash, as shown in Fig.15.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig17

AIR CONDITIONER FEATURES

Control Panel

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig18

Note: Refer to the Quick Start Guide that came with your Smart Air Conditioner for detailed instructions on setting up your air conditioner for connected operation from your smart phone or tablet.

OPERATING INSTRUCTION

To change temperature setting

  • Press the “ ” button to turn the unit ON.
  • The unit will run in “Cool” mode with a set temperature of 72°F.
  • Press the “ ” or “ ” button to choose the temperature in a range of 60°F – 90°F (16°C – 32°C).

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig28

Cool mode

  • Press the “Mode” button until the Cool mode indicator lights up.
  • Press the “fan speed” button to choose the fan speed according to the illumination of the fan speed indicator.
  • You can choose the “Auto”, “Lo”, “Med”, or “Hi” fan speed setting.
  • Press the “ ” or “ ”button to choose the temperature you want.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig29

Dry mode

  • Press the “Mode” button until the Dry mode indicator lights up. In this mode, the “ ” or “ ” button is disabled and the screen displays the room temperature. The unit will continuously drain moisture from the room.

Note: In this mode, the fan speed will be automatically set to “Lo”, which cannot be changed.

  • In this mode, condensate drainage is required, refer to the “Drainage Instructions” on Page 21 for more instructions to drain the excess condensate.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig30

Fan mode

  • Press the “Mode” button until the Fan mode indicator lights up.
  • In this mode, you can select fan speed “Lo”, “Med”, or “Hi”.
  • In this mode, the “ ” or “ ” button is disabled and the screen displays the room temperature.

Note: In this mode, the air exhaust hose does not need to be connected.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig30

Auto mode

  • Press the “Mode” button until the Auto mode indicator lights up.
  • Press the “ ” or “ ” button to choose the temperature you want. The screen will display the temperature setting.
  • In this mode, the unit will automatically select cooling, or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically around the temperature point set by you.

Note: In this mode, the unit will run in Auto fan speed and cannot be changed.

 

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig32

Louver Swing Function

Press the “Swing” button to enable louver swing function, the swing indicator will illuminate and the louver on the top panel will swing up and down. Press this button again to disable the louver swing function.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig32

Sleep mode

  • When the unit is in Cool or Auto mode, you can press the “Sleep” button on remote control to make the unit run in Sleep mode.
  • In this mode, the fan speed will automatically set to “Auto”, which cannot be changed. In Cool mode the selected temperature will increase by 2 °F 30 minutes after the mode is selected. The temperature will then increase by another 2 °F for an additional 30 minutes.
  • This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the “Sleep” mode and the unit will continue to operate as originally programmed.
  • The Sleep mode program can be cancelled at any time during operation by pressing the “Sleep”, “Mode”, “Fan speed” or “ ” button.

Note: In Fan or Dry mode, Sleep mode cannot be set. During Sleep mode the brightness of the indicators will reduce by half.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig34

Dust filter reset

  • This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more ecient operation.
  • The “Clean” indicator will illuminate after 250 hours of fan operation. Press and hold the “Dust Filter” button for 3 seconds to reset, after cleaning the filter.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig35

Replace indicator

  • This feature is a reminder to replace the Advance Filter (not included, sold separately) for more efficient operation.
  • The “Replace” indicator will illuminate after 4000 hours of fan operation. Press and hold the “Pure Air TM” button for 3 seconds to reset, after replacing the advanced filter.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig36

Child Lock

Press and hold the Mode and “ ” button for 3 seconds to activate the Child Lock mode. In this mode, the unit’s setting cannot be changed by pressing the buttons on control panel. The display will show “LC” for 5 seconds then return to the normal display. Press and hold the Swing and Sleep button for another 3 seconds to quit this mode.

Note: After the child lock feature activated the setting can still be changed by remote control or app.

°F/°C function

Press the “ ” and “ ” button at the same time for more than 3 seconds to switch between degrees Fahrenheit and degrees Celsius.

Note: Under Dry/Fan mode, you cannot select °F/°C.

Ionizer function

The unit is equipped with an internal air cleaning device called an ionizer. This feature can be activated and deactivated by pressing and holding the “Swing” button for 2 seconds or via the Frigidaire app, which can be downloaded onto your smart phone device. By activating this function, the ionizer will generate ions into the air, attracting and removing impurities from the air. This provides cleaner, healthier air to breathe.

OPERATING INSTRUCTIONS

Remote Control

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig19

Battery Installation and Important Instructions

  • Remove the cover at the back of the remote control.
  • Insert the provided batteries correctly(see the instructions inside the battery compartment).
  • Close up the cover.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig20

  • To replace the old batteries(which have been used up) with two new R03 “AAA” 1.5V batteries, repeat the steps above. If the remote control unit is replaced or discarded, the batteries must be removed and disposed of in accordance with local legislation as they do harm to the environment.
  • Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc)
  • or rechargeable (nickel-cadmium) batteries.
  • Do not dispose of batteries in fire. Batteries may explode or leak. If the remote control is not used for a long time, remove the batteries from the remote control.
  • The remote control must be handled with extreme care. Do not drop it or expose it to direct sunlight or sources of heat.
  • Point the remote control at the location of the signal receiver. The remote control must be no more than 16 ft(5 meters) away from the unit (without obstacles between the remote control and the unit).

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig21

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation.

How to Use the Remote Control Turning the unit on

  • Plug in the unit, then press the “on·off” button.
  • When turned on, the unit will operate according to the last settings before shutdown.
  • To switch the unit off, press “on·off” button again, then remove the plug.
  • Do NOT switch the unit off by removing the plug. Always switch the unit off by pressing the “on·off” button and wait for few minutes before removing the plug.

Cool mode

  • Press the “mode” button until the left side of LCD screen displays “cool”.
  • Press the “speed” button to choose the fan speed “auto”, “high”, “mid”, and “low”.
  • Press the “ ” and “ ” button to choose the temperature you want.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig32

Dry mode

  • Press the “mode” button until the left side of LCD screen displays “dry”.
  • In this mode, the “ ” or “ ” button is disabled and the screen will remain blank.
  • The unit will continuously drain moisture from the room.

Note:

In this mode, the fan speed will be set as “low” automatically, which cannot be changed. In this mode, condensate drainage is required, refer to the “Drainage Instructions” on Page 21 for more instructions to drain the excess condensate.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig33

Fan mode

  • Press the “mode” button until the left side of LCD screen displays “fan”.
  • In this mode, you can select fan speed “high”, “mid”, “low” by pressing the Fan speed button and referring to the diagram.

Note: In this mode, the air exhaust hose does not need to be connected.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig34

Auto mode

  • Press the “mode” button until the left side of LCD screen displays “auto”.
  • Press the “ ” and “ ” button to choose the temperature you want.
  • In this mode, the unit will automatically select cooling, heating(not applicable for cooling only models), or fan only operation depending on what temperature you have selected and the room temperature.
  • The air conditioner will control room temperature automatically round the temperature point set by you.

Note: In this mode, fan speed cannot be selected.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig35

Louver Swing Function

Press the “swing” button to enable louver swing function, and the upper side of screen will display “ ”. The louver on the top panel will swing up and down. Press this button again to disable the louver swing function.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig22

Sleep mode

  • When the unit is in Cool, Heat or Auto mode, you can press the “sleep” button to make the unit run in Sleep mode. In this mode, the fan speed will be set as “Auto” automatically, which cannot be changed.
  • In Cool/Heat mode the selected temperature will increase/decrease by 2 °F 30 minutes after the mode is selected. The temperature will then increase/decrease by another 2 °F after an additional 30 minutes.
  • This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the “Sleep” mode and the unit will continue to operate as originally programmed.
  • The “Sleep” mode program can be cancelled at any time during operation by pressing the “Sleep”, “mode”, “fan speed” or “on·off” button.

Note: In Fan or Dry mode, Sleep mode cannot be set.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig36

°F/°C function

Press the “ ” and “ ” button at the same time for more than 3 seconds to switch between degrees Fahrenheit and degrees Celsius.

Note: Under Dry/Fan mode, you cannot select °F/°C.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig37

Timer mode

How to delay startup

Plug in the unit, so the unit turns to standby. Press the “timer” button, when the unit is off. The screen will display “timer” and “h”, and “on” will flash. Tap or hold the UP arrow ” ” or the DOWN arrow ” ” to change delay start timer at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. After 3 seconds, the timer function is enabled, then “on” will stop flashing, the display will show the temperature and the control will count down the time remaining until startup. The unit will start up in the mode as previously set. To cancel the setting, press the “timer” button again. You can also cancel the setting by pressing the “on·off” button.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig38

How to delay shutdown

You can delay shutdown when the unit is on. Press the “timer” button, when the unit is on. The screen will display “timer” and “h”, and “off”  will flash. Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay shutdown timer at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. After 3 seconds, the timer function is enabled, then “off ” will stop flashing, the display will show the temperature and the control will count  down the time remaining until shutdown. To cancel the setting, press the “timer” button again. You can also cancel the setting by pressing the “on·off” button.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig39

Drainage Instructions

Continuous Drainage During the Dry mode, you will need a garden hose (sold separately) to drain the condensate from the unit. Follow the steps below:

  • Unscrew the drain cap of continuous drain outlet(Fig.20).

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig23

  • Connect one end of the garden hose (sold separately) to the drain outlet then lead the other end into a drain that is lower than the unit(Fig.21).

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig24

NOTE:

  • Condensate may flow out after removing the drain cap, if the unit is running in Cool or Auto mode. When you want to remove the garden hose, prepare a drip tray (not supplied) to collect the condensate from the drain outlet.
  • Please be sure that the height of the drain and section of the drain hose should not be higher than that of the drain outlet, or the continuous drainage may not work properly.
  • During Cool or Auto mode, it is recommended to disable continuous drainage by replacing the drain cap to the drain outlet, to reach the maximum performance.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig24

Emptying the condensate residue inside the unit during winter storage.

  • Put a drip tray (not supplied) under the continuous drain outlet, then unscrew the drain cap to allow the condensate to flow into the drip tray. Replace the drain cap to the continuous drain outlet when no condensate flows out.
  • Put the drip tray under the bottom drain outlet, then remove the rubber stopper from the drain outlet, to allow the condensate to flow into the drip tray. If your drip tray can’t hold all the condensate, a number of fills will be needed.
  • Replace the drain cap to the bottom drain outlet when no condensate flows out.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig26

Note: To ensure all condensate residue has been removed, tilt the unit by lifting it slightly upwards from the front until no more condensate comes out from the drain outlet.

CARE AND CLEANING

Cleaning

Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.

CLEANING THE UNIT

  • The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent.
  • Never use harsh cleaners, wax or polish on the cabinet front.
  • Be sure to wring excess water from the cloth before wiping around the controls.
  • Excess water in or around the controls may cause damage to the air conditioner.

CLEANING THE FILTERS

  • To keep your air conditioner working efficiently, you should clean the filters every week of operation.
  • This unit has two filters, they are filter A and B. Grasp the upper panel tab and take o the filter A which behind the grill of the back panel (Fig.25). Remove the lower filter B by loosening the screw. Take down the air inlet grille, then remove the air filter as shown in Fig.25.
  • Wash the filter using liquid dishwashing detergent and warm water.
  • Rinse filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing. Or, instead of washing you may vacuum the filter clean.
  • Replace the filter after the filter is dry.

Winter Storage

If the air conditioner will not be used for an extended period of time:

  • Drain the water collection tank completely and leave the bottom drain cap and rubber plug off for an extended period of time to allow any residual. Once the tank is completely drained and no more water flows out, reinstall the rubber plug and cap.
  • Remove and clean the filter, allow it to dry completely, then reinstall it.
  • Remove the batteries from the remote control.

Frigidaire-FHPW122AC1-3-in-1-Connected-Portable-Room-Air-Conditioner-Fig27

  • Store the air conditioner in a cool, dry location, away from direct sunlight, extreme temperature, and excessive dust.

Before using the air conditioner again:

  • Make sure the filter and drain cap are in place.
  • Check the cord to make sure it is in good condition, without cracks or damage.
  • Place new batteries in the remote control.
  • Install the air conditioner as described in the Installation Instructions.

BEFORE YOU CALL

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig46

Frigidaire-Portable-Room-Air-Conditioner-with-Dehumidifier-Fig47

If These Solutions Fail, Call 1-800-944-9044(US)/1-800-265-8352(Canada) For Frigidaire Service.