Before First Use
To prevent any internal damage, it is very important to keep the unit upright throughout its journey. Please leave it standing upright and outside the box for 24 HOURS before plugging it in. In the event this product malfunctions, or you believe it is defective, please contact Customer Service at homelabs.com/help, or help@homelabs.com and hold onto the defective product (pending further instruction).

A defective product should be clearly marked or stored where it cannot be used by mistake. Failure to keep the product in its original quality from the time of receipt may impede hOmeLabs’s ability to correct any legitimate problem and may limit the extent to which hOmeLabs may provide recourse.

Important Safety Instructions

PRODUCT DESCRIPTION
This dehumidifier removes moisture from interior spaces and is commonly used in basements, warehouses, homes, and other places. R32 is used as a refrigerant in this unit. R32 is generally considered environmentally benign. Care should be taken when handling or using devices with R32 due to its flammability.

SYMBOLS FROM THE UNIT AND USER MANUAL 

  • THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY.
  • This appliance is not intended for use by persons (including children with reduced physical, sensory, or mental capabilities or lack of experience and knowledge unless they have been given instruction concerning its use and supervised by a person responsible for their safety or care. Keep out of reach of children under eight (8) years old.
  • This appliance is designed for indoor use only. Do not use outdoors.
  • The unit is designed only for use with R32 (propane) gas as the designated refrigerant. The propane gas used in the unit has no odor. The lack of smell does not indicate a lack of escaped gas.
  • The refrigerant loop is sealed. Only a qualified technician should attempt to service!
  • Do not discharge the refrigerant into the atmosphere.
  • R32 (propane) is flammable. The propane gas used in the unit has no odor.
  • If propane gas is present or even suspected, If propane gas is present or even suspected, immediately open windows or ventilate the room. Do not turn on or activate the unit if the unit is off. If the unit is on, immediately terminate the use of the unit. Do not allow untrained personnel to attempt to find the cause. Do not allow untrained personnel to attempt to find the cause.
  • Do not let any persons back into the room until the qualified service technician has arrived and that technician advises that it is safe to return to the room.
FOR YOUR SAFETY
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
  • The appliance shall be disconnected from its power source during service.
  • Always operate the unit from a power source of equal voltage, frequency, and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Unplug the power cord when cleaning or when not in use.
  • Do not operate with wet hands. Prevent water from spilling onto the unit.
  • Do not immerse or expose the unit to rain, moisture, or any other liquid.
  • Do not leave the unit running unattended. Do not tilt or turn over the unit.
  • Do not unplug while the unit is operating.
  • Do not unplug by pulling on the power cord.
  • Do not use an extension cord or an adapter plug.
  • Do not put objects on the unit.
  • Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet or the aluminum fins of the unit.
  • Do not operate the unit if it is dropped, damaged, or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  • Ensure the unit is far away from fire, inflammable, or explosive objects.
  • Ensure the unit is installed in accordance with national wiring regulations the unit.
  • Do not use any means to accelerate the defrosting process or to clean.
  • The appliance shall be stored in a room without continuous heat sources (for example open flames, an operating gas appliance, or an operating electric heater)

Installation

ACCESSORIES

Homelabs-HME021007N-Commercial-Dehumidifier-User-Manual-fig-1

PARTS NAMEDIMENSIONSQUANTITY
1. Main Body
2. Handle
3. Screw6 × 35 mm4 pcs (2 spare)
4. Washer13 × 24 × 3 mm2 pcs (4 spare)
5. Wheel2 pcs
6. Locating Pin2 pcs
7. Caster2 pcs
8. Screw4 × 10 mm8 pcs (4 spare)
9. Axle
10. ScrewM6 × 25 mm2 pcs (1 spare)

Attach the Handle

  1. Place the device on its front side.
  2. Mount the Handle (2) to the device sides using Screws (3). The hole sites must be aligned on both sides.

Mounting the Casters

  1. Lay down the unit by pulling the Handle backward. This will reveal the appliance’s bottom.
  2. Fix the two Casters (7) with Screws (8) to the two brackets on the appliance’s bottom by using a screwdriver (we recommend electric). Each Caster. Each Caster should be installed using four Screws.

Mounting the Wheels

  1. Place the device on its front side.
  2. Attach an Axle (9) with 2 Screws (10) to the bottom of the device by using a screwdriver
  3. Add a Washer (4) onto the Axle.
  4. Mount a Wheel (5) in front of the Washer.
  5. Use a Locating Pin (6) to secure the Wheel (5) on the Axle.
  6. Repeat steps 2 to 5 to install the Axle on the other side.
  7. After mounting the Casters and the Wheels, place the device in an upright position.

Install the Drain Hose
Attach the supplied Drain Hose to the Drainage Port on the appliance. Direct the Hose to the desired area before operating the appliance.

Homelabs-HME021007N-Commercial-Dehumidifier-User-Manual-fig-2

  • If the drain area is located above the Dehumidifier, the maximum capacity of the water pump is 16.4 ft (5 m). If the water is drained downwards, there is no limit to the distance.

WARNING:
Do not block the Drain Hose. The end of the Drain Hose should not be higher than the outlet hole. If the end of the Drain Hose is higher than the outlet hole, water will not drain properly and could damage the components of the unit.

PARTS OVERVIEW 

Homelabs-HME021007N-Commercial-Dehumidifier-User-Manual-fig-3

Operation

POSITIONING THE APPLIANCE

Homelabs-HME021007N-Commercial-Dehumidifier-User-Manual-fig-4

  • This unit may have been tilted or placed upside down during shipping. To ensure this device works properly, please stand this unit upright for at least 24 hours before initial use.
  • This Dehumidifier is designed to operate in a working environment between 41°F (5°C) and 90°F (32°C).

CONTROL PANEL 

Homelabs-HME021007N-Commercial-Dehumidifier-User-Manual-fig-5

To Turn On/Off the Appliance

  • Plug in the appliance, the screen will light up. Press the “Power” button. The unit will start working in continuous mode. The screen displays the room humidity. The Compressor will start to work 3 seconds after the Fan starts working.
  • To turn off the appliance, press the “Power” button. The screen displays the room humidity and the appliance goes into standby mode. The Fan will run for another minute before stopping.

Adjusting the Timer

  • Auto On: Press the “Timer” button while the appliance is off. The “Timer” indicator will light up. Press the “Increase / Decrease” button to set the time you want to start the appliance. When the countdown is over, the Fan and the Compressor will turn on.
  • Auto Off: Press the “Timer” button while the appliance is running until the “Timer” indicator lights up. Press the “Increase / Decrease” button to set the time you want the appliance to turn off. When the countdown is over, the Fan and Compressor will shut off.
  • To display the current temperature, press and hold the “Timer” button for 3 seconds. After 10 seconds, the screen will display current humidity.

To Set the Humidity Level
The default set humidity level is 50% RH. To adjust the humidity level, press and hold the “Increase” or “Decrease” button. The humidity level can be increased or decreased by increments of 5% RH in normal mode.

To Use the Continuous Mode

In continuous mode, the humidity setting is invalid. The continuous mode indicator turns on and the screen will display the current humidity. To exit the continuous mode, press the “Cont.” button. The humidity setting is resumed.

Water Drainage

  • When the Water Tank is full, the Water Pump will start automatically. The “Full” indicator will illuminate red. After 35 seconds, the Water Pump will stop and the “Full” indicator will turn off.
  • To drain the water manually, press and hold the “Drain” button. This works even when the tank does not indicate “Full”. The Water Pump will operate for 35 seconds before stopping. Repeat until all water is drained.
  • The “Full” indicator will turn on and off according to the Water Pump status.

Operation

  • The system has auto memory. If there is a sudden power loss during operation, the system restores the last settings before the power loss and will resume operation when powered on.

Defrost Function

  • The appliance will defrost automatically when it is operating at low temperatures. The compressor and the Fan will shut off if the environmental temperature is below 41°F or above 100.4°F.
  • After the Compressor runs for 30 minutes, the temperature sensor will detect the copper pipe temperature. When the detected temperature is ≤30.2°F in the last 10 seconds, the Compressor will stop and start to defrost. The Fan will keep working and the “Defrost” indicator will turn on. When the pipe temperature reaches 41°F or the defrost lasts for 15 minutes, the appliance quits the defrosting.
Error Codes

In case of malfunction, the appliance will display an error code. E1 – Temperature sensor issue. The system will work in cycles of dehumidification for 30 minutes and defrosting for 15 minutes. The temperature sensor needs to be replaced. Please call Customer Service for further support. E2 – Humidity sensor issue. The humidity adjusting button will not work. The system will work in cycles of dehumidification for 30 minutes and defrosting for 15 minutes. The humidity sensor needs to be replaced. Please call Customer Service for further support.

Cleaning and Maintenance

  • Clean the appliance exterior with a soft wet cloth.
  • Clean the Filter Pull the louver on the front panel out to gain access to the Filter.
    Homelabs-HME021007N-Commercial-Dehumidifier-User-Manual-fig-6
  • Remove the Filter.
  • Use a clean rag to absorb the surface dust on the Filter. If the Filter is extremely dirty, use potable tap water to flush it. Fully dry the Filter before putting it into the Air Inlet panel. A clean Filter will increase the appliance’s efficiency.
  • Clean the Filter with potable water at least once every 30 days.
    Homelabs-HME021007N-Commercial-Dehumidifier-User-Manual-fig-7

Storage Requirements
If the unit will remain unused for an extended period of time, follow the steps below:

  • Clean the Filter.
  • ATTENTION! The evaporator inside the appliance has to be dried out before the unit is packed to avoid component damage. Unplug the unit and place it in a dry open area for several days to dry it out.
  • Store the power cord on the Power Cord Hooks at the back of the unit.
  • Cover the Dehumidifier with a plastic bag or a tarp.
  • Store the Dehumidifier upright in a dry, well-ventilated location

Specifications

Voltage & FrequencyAC 115 V, 60 Hz
 

 

 

Rated Capacity

45 Pints / Day @ 65°F, 60% RH
70 Pints / Day @ 80°F, 60% RH
120 Pints / Day @ 86°F, 80% RH
160 Pints / Day @ 95°F, 90% RH
 

 

 

Power Consumption & Current

532 W / 4.7 A @ 65°F, 60% RH
660 W / 5.8 A @ 80°F, 60% RH
780 W / 6.8 A @ 86°F, 80% RH
930 W / 8.1 A @ 95°F, 90% RH
Noise≤60 dB(A)
Air Circulation265 CFM
Refrigerant Type & CapacityR32 / 6.71 oz
Minimum Current of Power Supply15 A
 

Maximum Design Pressure

High Side: 550 psig
Low Side: 260 psig
Compressor InputRLA: 5.5 A LRA: 27 A
Fan Motor Power0.100 HP

Troubleshooting

PROBLEMCAUSESOLUTION
 

 

 

 

The appliance does not run

 

• The Dehumidifier is not plugged in securely.

• A fuse blew or a circuit breaker tripped.

 

• Make sure the Dehumidifier’s plug is inserted completely into the outlet.

• Replace with a new fuse or reduce power-consuming devices.

 

The room temperature is under 41°F or above 100.4°F.

To protect the appliance, use it only when the ambient temperature is between 41°F and 100.4°F.
 

 

 

 

The appliance runs but does not dehumidify

 

• Did not allow enough time to remove the moisture.

• The humidity level may not be set low enough.

• Doors, windows or other openings were left ajar/open.

• There is a kerosene heater or another appliance producing water vapor in the room.

 

 

• Allow enough time to remove the moisture.

• Reset the humidity level.

• Check that all doors, windows and other openings are securely closed.

• Remove the objects giving off water vapor in the room.

 

Reduced Dehumidifier capacity

The filter mesh is jammed.Clean the filter mesh.
 

The air-in and/or air-out louvers are jammed.

 

Clear the blockage from the air-in and air-out louvers.

 

No air inlet

The filter mesh or air-in louver is jammed.Clean the filter or the louver blockage.
 

 

Loud aspirating noise

The appliance is placed on an incline or decline slope. 

Move the appliance to flat ground.

 

The filter mesh is jammed.

 

Clean the filter mesh.

 

 

Water on the floor

 

• Hose to connector or Hose connection may be loose.

• Hose is kinked.

 

• Reconnect the Hose securely.

• Fix the Hose.

 

Warranty

HOmeLabs offers a limited one-year warranty (“warranty period”) on all of our products purchased new and unused from hOmeLabs Technologies, LLC or an authorized reseller, with original proof of purchase and where a defect has arisen, wholly or substantially, as a result of faulty manufacture, parts, or workmanship during the one-year warranty period. The warranty does not apply where damage is caused by other factors, including without limitation to

  • (a) normal wear and tear;
  • (b) abuse, mishandling, accident, or failure to follow operating instructions;
  • (c) exposure to liquid or infiltration of foreign particles;
  • (d) servicing or modifications of the product other than by hOmeLabs;
  • (e) commercial or non-household use. The hOmeLabs warranty covers all costs related to restoring the proven defective product through repair or replacement of any defective part and necessary labor so that it conforms to its original specifications. A replacement product may be provided instead of repairing a defective product. hOmeLabs’s exclusive obligation under this warranty is limited to such repair or replacement. A receipt indicating the purchase date is required for any claim, so please keep all receipts in a safe place. We recommend that you register your product on our website: homelabs.com/reg. Although greatly appreciated, product registration is not required to activate any warranty, and product registration does not eliminate the need for the original proof of purchase. The warranty becomes void if attempts at repair are made by non-authorized third parties and/or if spare parts, other than those provided by hOmeLabs, are used. You may also arrange for service after the warranty expires at an additional cost.

These are our general terms for warranty service, but we always urge our customers to reach out to us with any issue, regardless of warranty terms. If you have an issue with a hOmeLabs product, please contact us at 1-(800)-898-3002, and we will do our best to resolve it for you. This warranty gives you specific legal rights, and you may have other legal rights that vary from state to state, country to country, or province to province. The customer may assert any such rights at their sole discretion.

Manufacturing Information

This manual covers all items with these model numbers:

HME010231N
HME010233N

Rated Voltage/Frequency: 100–240 V ~ 50/60 Hz
HME010231N Dimensions: 16.2″L × 10.3″W × 22.5″H
HME010233N Dimensions: 16.2″L × 10.3″W × 33.5″H

WARNING: