Warnings
- Failure to follow these instructions could result in damage to the product and avoid the factory warranty
- The accuracy of the door preparation is critical for the proper functioning and security of this product. Misalignment can cause performance degradation and lessening of security.
- Finish Care: This lockset is designed to provide the highest standard of product quality and performance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners, or polishes could damage the coating and result in taming.
IMPORTANT:
Do not install batteries until the lock is completely installed on the door.
- Master PIN Code (4~10 digits): The default master PIN code is “12345678”,, please modify it after installation. If you forget your master PIN code, you can reset your lock back to factory settings.
- User PIN Code (4~10 digits): User PIN codes can be set up through the master PIN code. Up to 20 user PIN codes can be stored.
- Both master and user pin codes don’t support the following combination of numbers.
Parts Illustrations
Definitions
Master Mode The master mode can be entered by entering[ **+Master PIN Code+# ] to program the lock. Master PIN Code: The master PIN code is used for programming and feature settings. Auto Re-lock: After successful pin code entry and the unit unlocks, it will automatically re-lock after 30 seconds. This feature is disabled in the default setting.
Manual Mode: The auto re-lock function could be adjusted to manual mode. In manual mode, the lock could be locked only by pressing any key for 2 seconds from outside or using a thumb turn from inside. Shutdown Time: The lock will shut down for a default of 3 minutes and not allow operation after the wrong code entry limit (10 times) has been met.
When the unit is shut down, the light will flash when you are trying to use the keypad. Silent Mode: The beeper will not make any voice. Status indicators: Located on exterior assembly. User PIN code: The user pin code operates the lock. The maximum number of user pin codes is 20. Reset button: After the reset operation, the lock will be restored to factory default settings, and all user credentials will be.
Factory Default settings
Lock Operation
Notes:
- Beeps sound only when the beeper is enabled.
- If the indicators show 3 red lights + 3 beeps, your setting fails. The system will exit master mode. Please try to enter master mode again if you continue your processing.
How to use
Unlock the door
- Unlock the door from outside Master/user PIN code or key.
- Unlock the door from inside Manual thumb turn
Turn the thumb on the inside body.
Lock the door
- Lock the door from the outside.
- Lock the door from inside
Auto Re-lock Mode
In Auto re-lock mode, the bolt will extend out automatically in 30 seconds after unlocking.
Manual Mode
Press any key on the keypad for 2 seconds.
Auto Re-lock Mode
In Auto Re-lock mode, the device will be locked automatically.
Manual Mode
The device could be locked by turning the thumb on inside body.
Unlock with Fake PIN code
Users can prevent pin code exposure from strangers by entering random digits before or after the pin code.
Reset to factory default settings
Operations on lock
- Open the battery box and find the reset button.
- The user a sharp thing to press and hold the reset button.
- Keep holding the reset button and remove a battery from the battery box then replace it.
- Keep holding the reset button for another 3 seconds until you hear the voice guide.