Oritis HWHC-01 In-Wall Humidity Controller User Instructions
Product Manual
Thank you for purchasing the Oritis In-Wall Humidity Controller. We will provide you with the best quality service.We are certain that you will find this is the most dependable and accurate unit available in the consumer market. The Ortis Humidity Sensor uses a microprocessor combined with the most advanced digital sensing technology,The Sensor and Fan Control automatically detects excess humidity in a room and activates the ventilation fan to lessen condensation which helps reduce mold and mildew. and displays real-time humidity on the LCD screen to reduce energy consumption. It is easy to view and manage the humidity level of the house area prone to condensation and mold. It has multiple modes such as automatic mode, manual mode and engineer mode.
Safety and Precautions
- Avoid fire, electric shock or death: turn off the power on the circuit breaker or fuse, and test that the power is off before wiring!
- To avoid personal injury or property damage, do not install control sockets or load exceeding the specified rating.
- Install and/or use in accordance with electrical codes and regulations.
- If you are not sure about any part of these instructions, please consult an electrician.
- Only use a damp cloth to gently clean the outer surface. Do not use soap or cleaning fluid.
- There are no user-serviceable components. Do not attempt to repair or repair.
- Only use this equipment with copper wire or copper-clad wire.
Wiring diagram
Get to know the controller
Button Operation Instructions
Up/Down Button
In the normal state, press and hold Up/Down Button for 3 seconds, the controller will enter the manual off mode(more detail on 5.5); press Up/Down Button again, the controller will return to normal state.
Mode Button
In normal On state, press , the controller will run manual on mode, press again, the controller will return automatic mode. The controller default mode is automatic mode.
Setting Menu Instruction:
Code | Function | Setting Range | Default setting | Annotation |
01 | Set humidity value | 30%~80% | 55% | More detail on 5.7 |
02 | Set Humidity difference | 6%~20% | 10% | More detail on 5.7 |
03 | Set automatic minimum runtime | 1 min~60 min | 1 min | More detail on 5.2.1 |
04 | Set manual on time | 1 min~60 min | 1 min | More detail on 5.2.2 |
05 | Set manual off time | 4 h~16 h | 8 h | More detail on 5.5 |
06 | Set humidity calibration value | -10%~10% | 0% | More detail on 5.6 |
07 | Dehumidification/Humidification mode | 1 or 2 | Dehumidification mode | More detail on 5.7 |
Lock Button
In normal state, simultaneously hold press both M button and Up/Down button for 3 seconds, the button will be lock; press both M button and Up/Down button again for 3 seconds, the button will be unlock.
Manual and Automatic Mode
Automatic Mode
In automatic mode, the controller turns the load on and off according to the humidity value you set.And the fan is turned on for at least 1 min(you can set it for 1-60 minutes). Generally, the main interface of the controller is in automatic mode, and the humidity you set and the current ambient humidity will be displayed on the LCD screen.
Manual Mode
In manual mode, the controller will turn on the load immediately. And the fan is turned on for at least 1 min(you can set it for 1-60 minutes).When the controller is in manual mode, this icon appears. The humidity detection area displays the current humidity, and the humidity setting area displays ’—’, after running for the time you set, it will return to automatic mode.
Backlight
The screen will lit on for 8 seconds when you press any button.
Key lock
When the keys are locked, a symbol will appear on the screen, In this state, pressing any button will turn on the backlight, and other functions cannot be used. The buttons must be unlocked for normal use.
Specifications
Input voltage: 110V/220 V
Power: 1800W, 3/4 Hp
Limited Warranty
If you have any problems installing or using this controller, please carefully and thoroughly review the instruction manual. If you require assistance, please write us to jack.s@etoolcity.net. We will reply your emails in 24 hours from Monday through Saturday. Ortis warrants this controller for two years from the date of purchase when operated under normal condition by the original purchaser(not transferable), against defects caused by Ortis’s workmanship or materials . This warranty is limited to the repair or replacement, at Oritis’s discretion, of all or part of the controller. The original receipt is required for warranty purposes.