You are currently viewing Ice-o-Matic ICEU070A Air Cooled ice maker User Manual

Ice-o-Matic ICEU070A Air Cooled ice maker User Manual

Ice o matic logo

Ice-o-Matic ICEU070A Air Cooled Ice Maker User Manual

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-prduct-img

ICEU070A

INTRODUCTION
This manual provides the specifications and the step-by-step procedures for the installation, startup, operation, maintenance, and cleaning of the ICEU070A ice machine. NOTE. To retain the safety and performance built into this ice machine, it is important that installation and maintenance be conducted in the manner outlined in this manual.

Specifications

The ice machine must be installed indoors in a controlled environment.

MinimumMaximum
Air Temp500F.950F.
Water Temp400F.1000F.
Water Pressure20 PSI80 PSI
Voltage103.5126.5

Operating the ice machine outside of the above limitations, or outdoors, is potentially damaging to the machine, and it is a misuse of the machine. This may void the warranty. Ice-O-Matic ice machines are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of agencies like NSF and UL. Ice-O-Matic assumes no liability or responsibility of any kind for products manufactured by Ice-O-Matic that have been altered in any way, including the use of any part and/or other components not specifically approved by Ice-O-Matic.

ModelElectrical (volts/Hz/phase)Fuse Size AmpsCondenser TypeRefrigerant Charge
ICEU070A115/60/115 6Forced Air9.5 oz R-134a

Ice-O-Matic reserves the right to make design changes and/or improvements at any time. Specifications and design are subject to change without notice.

UNPACKING AND INSPECTION

  1. Call your authorized Ice-O Matic Distributor or Dealer for proper installation.
  2. Remove the front panel of the unit and inspect for any concealed damage. Notify the carrier of your claim for the concealed damage.
  3. Check that refrigerant lines do not rub against or touch other lines or surfaces and that the fan blade moves freely.
  4. Check that the compressor fits snugly onto all its mounting pads.
  5. Remove all internal support packing and masking tape.

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-1

General Information And Installation

This model is supplied from the factory completely pre-wired and requires only electrical power connections to the wire cord provided at the rear of the unit. Make sure that the ice machine is connected to its own circuit and individually fused (see data plate for maximum fuse size). This is a cord-connected unit designed for 115-volt AC power, with a maximum fuse size of 15 amps. Low voltage can cause improper operation and may be responsible for serious damage to the overload switch and motor windings that is not covered by warranty

Location:
If the unit is built into a cabinet with no side ventilation, the ice production will be reduced by 20% of rated capacity, restricted space of an inch or so on each side will cause a 10% reduction. Six inches of space to the left and right will allow the unit to operate satisfactorily. The daily ice-making capacity is directly related to the condenser air inlet temperature, water temperature, conditions of the condenser air filter, and age of the machine. To keep your Ice-O-Matic ice machine at peak performance levels, periodic maintenance checks must be carried out as indicated in the Maintenance and Cleaning section of this manual.

Warranty

The warranty statement for this product is on page 18 of this manual. Refer to it for applicable coverage. In general, a warranty covers defects in material or workmanship. It does not cover maintenance, corrections to installations, or situations when the machine is operated in circumstances that exceed the limitations printed in this manual.

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-2

Water Supply And Drain Connections

General When choosing the water supply for the ice cuber consideration should be given to:

  • a) Length of run
  • b) Water clarity and purity
  • c) Adequate water supply pressure

Low water pressure, below 20 psi may cause a malfunction. Water containing excessive minerals will tend to produce cloudy colored ice cubes, plus scale build-up on parts of the water system.

Water Supply
The recommended water supply line is a 3/8″ o.d. copper tube, the water pressure must have a minimum incoming pressure of 20 psig. Connect the tubing to the 3/4″ GAS / BSPP thread water inlet fitting at the back of the ice maker. An adapter is available, the part numbers are Water Inlet Adapter-1011411-64 and Water Inlet Adapter O-Ring-1011411-65.

Water Drain
The recommended drain tube is a plastic or flexible tube with 18 mm (3/4″) I.D. which runs to an open trapped and vented drain. Note: Although soft, easily kinked vinyl tubing is not recommended for a drain, a short length of ¾” ID vinyl tubing is required to connect a rigid drain tube to the 20 mm (25/32”) fitting on the back of the machine. NOTE. The water supply and the water drain must be installed to conform to the local code. In some cases, a licensed plumber and/or a plumbing permit is required.

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-3

Final Check List

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-4

  1. Is the unit in a room where ambient temperatures are above a minimum of 10oC (50o F) even in winter months?
  2. Is there at least a 15 cm (6″) clearance around the unit for proper air circulation?
  3. Is the unit level? (IMPORTANT)
  4. Have all the electrical and plumbing connections been made, and is the water supply shut-off valve open?
  5. Has the voltage been tested and checked against the data plate rating?
  6. Has the water supply pressure been checked to ensure a water pressure of at least 20 psi?
  7. Check all refrigerant lines and conduit lines to guard against vibrations and possible failure.
  8. Have the bolts holding the compressor down been checked to ensure that the compressor is snugly fitted onto the mounting pads?
  9. Have the bin liner and cabinet been wiped clean?
  10. Has the owner/user been given the User Manual and been instructed on the importance of periodic maintenance checks?
  11. Has the Manufacturer’s registration card been filled in properly? Check for the correct model and serial number against the serial plate and mail the registration card to the factory.
  12. Has the owner been given the name and phone number of the authorized Ice-O-Matic Service Agency serving him?

Operating Instructions

Start-Up After having correctly installed the ice maker and completed the plumbing and electrical connections, perform the following “Start-up” procedure.

  • A. Remove the condenser air filter then remove the front panel, Locate the cleaning switch on the control box.
  • B. Switch the cleaning switch to the cleaning position. This will close the electrical circuit to the water inlet valve and to the hot gas valve.
  • C. Switch the power ON and push the green button switch. The unit will start up in charging cycle mode. During this cycle, the components energized are:
    • Water inlet Solenoid Valve
    • Hot Gas Solenoid Valve
    • Water Pump
    • Fan Motor
  • D. Operate the unit in the water charging cycle for about three/four minutes till water flows out from the drain hose, then move the cleaning switch to the operation position.

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-5

NOTE.
During the charging cycle, the water inlet solenoid valve is energized. The water flows through the valve to the back side of the evaporator plate and then down to fill up the ice machine sump for the next freezing cycle.

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-6

Operational Check

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-7

  • E. The unit now starts its first freezing cycle with the following components in operation: Compressor Water Pump Fan Motor
  • F. Look through the ice discharge opening and confirm that the spray system is correctly seated and that the water jets uniformly reach the interior of the inverted cup molds; also make sure that the plastic curtain is hanging freely and excessive water is not flowing through it.
  • G. During the freeze cycle, the evaporator will remove heat from the water sprayed into the ice-making molds and warm air will be discharged from the cabinet.
  • H. When the evaporator temperature reaches a preset value the evaporator thermostat or cube size control changes its contacts; the freezing cycle ends and starts the defrost or harvest cycle. Freezing time will range between 20 and 22 minutes in a 70o F ambient temperature. Longer time for temperature above, shorter when below. The average complete cycle range is about 23 to 25 minutes.
  • I. Check, during the first defrost/harvest cycle, that the incoming water flows correctly into the sump to re-fill it and the surplus overflows through the overflow drain tube.
  • J. Check the size and shape of the ice cubes just released. The right size must have a small depression about 3/16” in their crown. If not, wait for the second defrost/harvest cycle before performing any adjustments.
  • K. If required, adjust the length of the freezing cycle by turning the knob of the cube size control or evaporator thermostat located in front of the control box until the correct ice cube size is achieved. If the ice cubes are shallow and cloudy, it is possible that the ice maker runs short of water during the end of the freezing cycle or, the quality of the supplied water requires the use of an appropriate water filter or conditioner.
  • L. During the defrost or harvest cycle hold a handful of ice cubes against the bulb of the storage bin thermostat; the ice machine switches OFF in about one to two minutes. Remove the ice from the storage bin thermostat. The ice maker should restart automatically in three to four minutes. NOTE. The bin thermostat is factory set at 1o C (35o F) OUT and 4o C (39o F) IN.
  • M. Re-attach the front panel, then instruct the owner/user on the general operation of the ice machine and about the cleaning and care it requires.

Component Description

Water Pump
The water pump operates continually throughout the freezing cycle. The pump forces the water from the sump to the spray system and through the spray nozzles so it sprays into the inverted cup molds to be frozen into crystal-clear ice cubes.

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-8

Water Inlet Solenoid Valve
The water inlet solenoid valve is energized only during the defrost cycle. When energized it allows a metered amount of incoming water to flow over the evaporator cavity to assist the hot gas in defrosting the ice cubes. The water running over the evaporator cavity drops by gravity, through the weep holes of the platen, into the sump.

Hot Gas Solenoid Valve
The hot gas solenoid valve consists basically of two parts: the valve body and the valve coil. Located on the hot gas line, this valve is energized by the contacts 3-2 of the evaporator thermostat during the defrost cycle. During the defrost cycle the hot gas valve coil is activated to attract the hot gas valve piston in order to give way to the hot gas discharged from the compressor to flow directly into the evaporator serpentine to defrost the formed ice cubes.

Bin Thermostat

The bin thermostat control body is located in the front of the control box behind the front louvered panel. The thermostat sensing tube is located in a bulb holder on the side wall of the ice storage bin where it automatically shuts the ice machine OFF when in contact with the ice and re-starts the ice machine when the ice is removed. Factory settings are 1o C (35o F) OUT and 4o C (39o F) IN

Bin Thermostat The bin thermostat control body is located in the front of control box behind the front louvered panel. The thermostat sensing tube is located into a bulb holder on the side wall of the ice storage bin where it automatically shuts the ice machine OFF when in contact with the ice and re-starts the ice machine when the ice is removed. Factory settings are 1o C (35o F) OUT and 4o C (39o F) IN

Cube Size Control (Evaporator Thermostat)
The cube size control (evaporator thermostat) body is located in the front of the control box behind the front louvered panel; it’s basically a reverse-acting temperature control that closes contacts 3-2 when its temperature decreases and closes the opposite contacts 3-4 when the temperature rises.

Operation – Electrical Sequence

The following charts illustrate which switches and components are ON or OFF during the two phases of the icemaking cycle. Refer to the wiring diagram for reference.

FREEZING CYCLE 

Electrical componentsONOFF
Compressor
Water Pump
Fan Motor
Hot Gas Valve
Inlet Water Valve
Electrical ControlsCLOSEOPEN
Evaporator Thermostat (contacts 3-4)

Evaporator Thermostat (contacts 3-2)  Bin Thermostat •

HARVEST CYCLE

  • Electrical components ON OFF
  • Compressor •
  • Water Pump •
  • Fan Motor (Air cooled only) •
  • Hot Gas Valve •
  • Inlet Water Valve •
  • Electrical Controls CLOSE OPEN
  • Evaporator Thermostat (contacts 3-4) •
  • Evaporator Thermostat (contacts 3-2) •
  • Bin Thermostat •

Average Discharge Pressure

  • A/C: 100 to 155 PSIG

Suction Pressure

  • End Freeze Cycle: 0 to 1.5 PSIG

Refrigerant Metering Device:

  • Capillary tube

Refrigerant Charge (R-134a)

  • 9.5 oz.

The thermostat sensing bulb is located in a plastic tube (bulb holder) secured by two clips directly to the evaporator serpentine. This control determines the length of the freezing cycle and correspondingly the size of the cubes. A lower setting will produce a larger cube (oversize) while a higher setting a smaller cube (shallow size). When closed on contacts 3-2 it activates the defrost or harvest cycle components. The cube size control is pre-set at the factory (knob in the black dot position) and doesn’t require any adjustment when the ambient temperature remains between 15o C and 30o C (60o F and 90o F).

Fan Motor
The fan motor is electrically connected in parallel to the water pump and it operates continuously only during the freezing cycle keeping the proper head pressure by circulating air through the condenser fins.

Compressor
The hermetic compressor is used to circulate refrigerant throughout the entire system. It compresses the low-pressure refrigerant vapor causing its temperature to rise and become high-pressure hot vapor (hot gas) which is then released through the discharge valve.

Water Spray System
Spray the water into each individual cup to be frozen into ice.

Cleaning Switch

Located on the bottom side of the control box, it is used to energize the water inlet and the hot gas valves to fill the sump of the machine with water when needed.

Green Master Switch Push Button
Located in the front of the machine it’s used to switch ON and OFF the unit by pushing its green push button. When ON, its green light is ON.

Red Alarm/Re-Set Push Button
Located in the front of the machine (just beside the Master Switch) it works in conjunction with the Cleaning Remind Board and it’s activated when:

  1. ON steady with machine in OFF mode Condensing temperature is higher than 70o C or 158o F. (air cooled version)
  2. Blinking twice and repeating with the machine in OFF mode Condenser sensor is out of order.
  3. ON steady with the machine in ON mode Condenser air filter needs to be cleaned.
  4. Slow blinking with the machine in ON mode.

The water system needs to be cleaned. In the first case, the machine can be Re-Set by pushing and holding the Red Alarm Re-Set Button for 5 seconds till the Red Light is OFF. In the second case, first, replace the condenser sensor then, push and hold the Red Re-Set Button for 5 seconds.

Cleaning Reminder PC Board

Located on the front left side of the machine, it works in conjunction with the condenser sensor and the Red Alarm Re-Set Push Button. It consists of

  • Printed Circuit Board with a step-down transformer (115V – 12V)
  • Relay
  • Dip Switch with two keys Jumper for the set up of the Cut OFF/Alarm condensing temperature (70oC 158oF.
  • jumper OUT – for air-cooled)
  • green four-wire connector for power IN and OUT
  • Red socket for the Water Level Sensor (future use)
  • Black socket for the Condenser Sensor and White socket for the Red Alarm Re-Set Push Button

The main function of this PC Board is to switch the machine OFF when the condensing temperature is too high or signal the need for cleaning the condenser air filter or the water system. The time between the signal for the cleaning of the water system can be modified according to the setting of the two Dip Switches as below:

1 MonthOnOn
3 MonthsOffOn
6 MonthsOnOff
1 YearOffOff

Once the water system has been cleaned, push and hold the Red Alarm Re-Set Button for more than 20 seconds until it starts to blink. That will reset the control.

Condenser Air Filter
It is located in front of the air-cooled condenser. It can be removed by pulling it through the opening in the front panel for cleaning or replacement. A lower plastic guide, installed inside the unit, is used for the correct sliding and location of the air filter.

Condenser Sensor
The condenser temperature sensor probe, located within the condenser fins detects the condenser temperature variations and signals them by supplying current, at low voltage, to the P.C. BOARD. In case the condenser temperature rises and reaches 70o C (160o F) – the control system will cause an immediate and total stop of the machine’s operation.

Service Diagnosis

SYMPTOMPOSSIBLE CAUSESUGGESTED CORRECTION
Unit will not runBlown fuseReplace fuse & check for cause of blown fuse.
Main switch in OFF positionTurn switch to ON position
Bin thermostat set improperlyAdjust rotating its setting screw
Loose electrical connectionsCheck wiring
Red Alarm light ONToo Hi Condensing TemperatureReset the machine (Push & hold the Reset Button for 5 seconds) and check for reason why
Red Alarm light Blinking TwiceCondenser sensor out of orderReplace it and repeat
Compressor cycles intermittentlyLow voltageCheck circuit for overloading
Check voltage at the supply to the building. If low, contact the power company
Non-condensable gas in systemPurge the system
Dirty condenserClean with vacuum cleaner, air or stiff brush. (DO NOT use wire brush).
Air circulation blockedAllow sufficient air space all around unit.
Compressor starting device loose wiresCheck for loose wires in starting device.
Cubes too smallCube size control set improperlyCheck and adjust for proper operation.
Capillary tube partially restrictedRecover charge, add new gas & drier, after evacuating system with vacuum pump.
Moisture in the systemSame as above.
Shortage of waterSee remedies for shortage of water.
Shortage of refrigerantCheck for leaks & recharge.
Cloudy cubesShortage of waterSee remedies for shortage of water.
Dirty water supplyUse water softener or water filter.
Accumulated impuritiesUse Ice Machine scale remover.
Shortage of water.Water spilling out through curtainCheck or replace curtain.
Water solenoid valve not openingReplace valve.
Water leak in sump areaLocate and repair.
Water flow control pluggedRemove and clean.
SYMPTOMPOSSIBLE CAUSESUGGESTED CORRECTION
Irregular cubes size & some cloudySome jets pluggedRemove jet cover and clean.
Shortage of waterSee shortage of water.
Unit not leveledLevel as required.
Poor pumpingCheck and/or replace the water pump.
Cubes too largeCube size control set improperlyCheck and adjust for proper operation.
Decreased ice capacityInefficient compressorReplace.
Leaky water valveRepair or replace.
Non-condensable gas in systemPurge the system.
Poor air circulation or excessive hot locationRelocate the unit or provide for more ventilation.
Overcharge of refrigerantCorrect the charge.
Capillary tube partially restrictedRecover charge, add new gas & drier, after evacuating system with vacuum pump.
Undercharge of refrigerantCharge to data plate indication.
Discharge head pressure too highSee incorrect discharge pressure.
Clogged air filterClean or replace.
Poor harvestRestriction in incoming water lineCheck water valve strainer and flow control. If necessary enlarge the flow control orifice.
Too short defrost timeCheck temperature control. Replace if necessary.
Cube size control set for too largeRe-set cube size control.
Water inlet valve not openingValve coil with open winding. Replace valve.
Hot gas valve orifice restrictedReplace hot gas valve assy.
Air vented holes in mold cups pluggedClean out holes.
Discharge head pressure too lowSee incorrect discharge pressure
Unit won’t harvestInoperative cube size controlReplace cube size control
Hot gas valve not openingValve coil with open winding. Replace valve.
Water solenoid valve not openingValve coil with open winding. Replace valve.
Incorrect discharge pressureDirty air filterClean or replace.
Inoperative hi press controlReplace.
Excessive water in unit baseWater tubing leaking Check.Tighten or replace.

Maintenance And Cleaning Instructions

GENERAL
The periods and the procedures for maintenance and cleaning are given as guides and are not to be construed as absolute or invariable. Cleaning, especially, will vary depending upon local water and ambient conditions and the ice volume produced; and, each ice machine must be maintained individually, in accordance with its particular location requirements.

Ice Machine
The following maintenance should be scheduled at least two times per year on these ice machines.

  1. Check and/or replace the water filter (if used).
  2. Check that the ice machine is leveled in side to side and in front to rear directions.
  3. Check for water leaks and tighten drain line connections. Pour water down the drain line to be sure that the drain line is open and clear.
  4. Check the size, condition, and texture of the ice cubes. Perform adjustment of cube size control as required.
  5. Check the bin thermostat to test shut-off.
  6. Check for refrigerant leaks.

Put a scoop full of ice cubes in contact with the bin thermostat bulb for at least one minute. This should cause the ice maker to shut off. Within a few seconds after the removal of the ice from the bin thermostat bulb, the ice machine restarts.

Clean – Replace the air Condenser Filter

  1. Withdraw the air filter from the front through the opening of the front panel.
  2. Remove the front panel.
  3. Blow pressurized air in the opposite direction of the condenser airflow to remove the dust accumulated. If pressurized air is not available, use tap water always in the counter flow air direction. Once cleaned shake it so as to remove most of the accumulated water, then dry it using a hair dryer.
  4. Return the front panel to its normal position.
  5. Install the filter by pushing it through the front panel opening.

Cleaning Water System

  1. Remove the ice from the bin.
  2. Remove the air filter and then the front panel.
  3. Rotate the control knob counterclockwise to the Off position.
  4. Turn off the water supply to the ice machine.
  5. Remove the top panel.
  6. Remove the plastic panel (evaporator cover) that covers the evaporator section.
  7. Remove the clamp and drain cap from the bottom of the reservoir, and allow all the water to drain out.
    Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-10
  8. . Return the drain cap and clamp to their original positions.
  9. Mix approximately 3 ounces (1/10 liter) of Scale Remover with 1.5 quarts (1.5 liters) of warm (95-115o F.) potable water, and pour this solution over the evaporator section (bright metal tubing and inverted cups in the white plastic tray at the top of the ice machine)
  10. Return the evaporator cover removed in step 6 to its normal position.
  11. Rotate the control knob to the Normal position.
  12. Operate the machine with the cleaning toggle switch in the Operation position for 5 minutes.
    Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-11
  13. Switch the cleaning toggle switch to the Cleaning position and operate the machine for 1 minute.
  14. Repeat steps 12 and 13 three times. After the third time rotate the control knob counterclockwise to the Off position.
  15. Remove the evaporator cover. Pour hot water over the entire surface of the evaporator section. Return the evaporator cover to its original position.
  16. Pour hot water into the bin to melt any ice produced during cleaning, and to clean out the drain. Wipe the interior of the bin with mild soap and hot water, rinse with cold water. To sanitize, mix a locally approved sanitizer solution and perform steps 17-31. A possible sanitizer solution may be obtained by mixing 1 ounce of household bleach with 2 gallons of warm (95-115 F) water.
  17. Remove the plastic panel (evaporator cover) that covers the evaporator section.
  18. Remove the clamp and drain cap from the bottom of the reservoir, and allow all the water to drain out.
  19. Return the drain cap and clamp to their original positions.
  20. Pour sanitizer solution over the evaporator section (bright metal tubing and inverted cups in the white plastic tray at the top of the ice machine).
  21. Spray or wash the bottom of the evaporator cover and the edges of the evaporator section with the sanitizing solution.
  22. Return the evaporator cover removed in step 17 to its normal position.
  23. Rotate the control knob to the Normal position.
  24. Operate the machine with the cleaning toggle switch in the Operation position for 4 minutes.
  25. Switch the cleaning toggle switch to the Cleaning position and operate the machine for 1 minute.
  26. Repeat steps 23 and 24 five times. After the fifth time rotate the control knob counterclockwise to the Off position.
  27. Remove the evaporator cover. Pour sanitizer solution over the entire surface of the evaporator section and wash or spray the evaporator cover bottom with sanitizer. Return the evaporator cover to its original position.
  28. Remove the curtain, remove the clamp and drain cap from the bottom of the reservoir, and allow all the water to drain out. Return the drain cap and clamp to their original positions.
    Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-12
    Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-13
  29. Thoroughly spray or wipe the interior of the ice storage bin, the bottom of the evaporator cover, and the spray platform with the sanitizing solution.
  30. Completely immerse the curtain in the sanitizing solution.
  31. Return the evaporator cover and curtain to their original positions.
  32. Reconnect water supply.
  33. Rotate the control knob to its original position. Switch the cleaning toggle switch to the Cleaning position for two minutes and then switch it to the Operation position. Operate the machine until one batch of ice has been released into the bin. Pour warm water over the ice to melt it.
  34. Return the front panel to its original position and secure with the original screws.

 

Ice-o-Matic-ICEU070A-Air-Cooled-Ice-Maker-User-Manual-fig-14

Parts and Labor

Domestic & International Limited Warranty
Mile High Equipment LLC (the “Company”) warrants Ice-O-Matic brand ice machines, ice dispensers, remote condensers, water filters, and ice storage bins to the end customer against defects in material and factory workmanship for the following:

· Cube ice machines,”GEM” model compressed ice machines ,” MFI” model flake ice machines and remote condensers. – Thirty-six (36) months parts and labor· Ice storage bins -Twenty-four (24) month parts and labor
· “EF” and “EMF” model flake ice machines – Twenty-four

(24) months parts and labor

· IOD model dispensers – Twenty-four (24) months parts, Twelve (12) months labor
· CD model dispensers – Thirty-six (36) months parts and labor· Water filter systems – Twelve (12) months parts and labor (not including filter cartridges)

An additional twenty-four (24) month warranty on parts (excluding labor) will be extended to all cube ice machine evaporator plates and compressors, “GEM” model compressed ice machine compressors, and “MFI” model flake ice machine compressors from the date of original installation. An additional thirty-six (36) month warranty on parts (excluding labor) will be extended to all “EF” and “EMF” model flake ice machine compressors from the date of original installation.

The company will replace EXW (Incoterms 2000) the Company plant or, EXW (Incoterms 2000) the Company-authorized distributor, without cost to the Customer, that part of any such machine that becomes defective. In the event that the Warranty Registration Card indicating the installation date has not been returned to Ice-O-Matic, the warranty period will begin on the date of shipment from the Company. Irrespective of the actual installation date, the product will be warranted for a maximum of seventy-two (72) months from the date of shipment from the Company.

ICE-model cube ice machines which are registered in the Water Filter Extended Warranty Program will receive a total of eighty-four (84) months parts and labor coverage on the evaporator plate from the date of original installation. Water filters must be installed at the time of installation and registered with the Company at that time. Water filter cartridges must be changed every six (6) months and that change reported to the Company to maintain the extended evaporator warranty.

No replacement will be made for any part or assembly which (I) has been subject to an alteration or accident; (II) was used in any way which, in the Company’s opinion, adversely affects the machine’s performance; (III) is from a machine on which the serial number has been altered or removed; or, (IV) uses any replacement part not authorized by the Company.

This warranty does not apply to destruction or damage caused by unauthorized service, using other than Ice-O-Matic authorized replacements, risks of transportation, damage resulting from adverse environmental or water conditions, accidents, misuse, abuse, improper drainage, interruption in the electrical or water supply, charges related to the replacement of non-defective parts or components, damage by fire, flood, or acts of God.

This warranty is valid only when installation, service, and preventive maintenance are performed by a Company-authorized distributor, a Company-authorized service agency, or a Company Regional Manager. The Company reserves the right to refuse claims made for ice machines or bins used in more than one location. This Limited Warranty does not cover ice bills, normal maintenance, after-install adjustments, and cleaning.

Limitation of Warranty

This warranty is valid only for products produced and shipped from the Company after January 2007. A product produced or installed before that date shall be covered by the Limited Warranty in effect at the date of its shipment. The liability of the Company for breach of this warranty shall, in any case, be limited to the cost of a new part to replace any part, which proves to be defective. The Company makes no representations or warranties of any character as to accessories or auxiliary equipment not manufactured by the Company.

REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CUSTOMER. MILE HIGH EQUIPMENT SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE LENGTH OF THIS WARRANTY.

Filing a Claim

All claims for reimbursement must be received at the factory within 90 days from the date of service to be eligible for credit. All claims outside this time period will be void. The model, the serial number and, if necessary, proof of installation, must be included in the claim. Claims for labor to replace defective parts must be included with the part claim to receive consideration. Payment on claims for labor will be limited to the published labor time allowance hours in effect at the time of repair.

The Company may elect to require the return of components to validate a claim. Any defective part returned must be shipped to the Company or the Company-authorized distributor, transportation charges pre-paid and properly sealed and tagged. The Company does not assume any responsibility for any expenses incurred in the field incidental to the repair of equipment covered by this warranty. The decision of the Company with respect to repair or replacement of a part shall be final.

No person is authorized to give any other warranties or to assume any other liability on the Company’s behalf unless done in writing by an officer of the Company. GOVERNING LAWhis Limited Warranty shall be governed by the laws of the state of Delaware, U.S.A., excluding their conflicts of law principles. The United Nations Convention on Contracts for the International Sale of Goods is hereby excluded in its entirety from application to this Limited Warranty.

REFERENCE LINK

https://www.iceomatic.com/products/59475/ICEU070A

Leave a Reply