LASKO-WALL-MOUNTED-OSCILLATING-FANS-FEATURE

LASKO Wall Mounted Oscillating Fans Operating Manual

Lasko-logo

LASKO Wall Mounted Oscillating Fans Operating Manual

LASKO-WALL-MOUNTED-OSCILLATING-FANS-img

 

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig1

IMPORTANT SAFETY INFORMATION

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock and injury to persons, including the following:
Read all instructions before using this Fan.

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig1 TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR PERSONAL INJURY, ALWAYS FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS AND WARNINGS:

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig2 DO NOT use this fan to ventilate areas where flammable liquids or vapors are used, stored or are present, including paints, gasoline, varnishes, floor refinishing products or solvents. ALWAYS read and follow all warnings and instructions on the containers for these products!

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig2

ALWAYS be sure the plug fits tightly into the outlet. When plugs fit loosely into outlets, they may slip partially out of the outlet and create a poor connection. This may cause outlets to overheat and create a potential fire hazard. Outlets in this condition should be replaced by a qualified electrician.

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig4ALWAYS unplug the power cord when servicing, cleaning or moving the Fan. DO NOT use the ON/OFF switch as the sole means of disconnecting power. NEVER leave children unattended when the Fan is on or plugged in. ALWAYS turn off and unplug the Fan when not in use.

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig4BE CERTAIN that the power source for the Fan is 120V AC. DO NOT plug the Fan into 240V or other power source.
The Blue Plug™ on your Air King fan is a safety feature. It contains a non-replaceable safety device (fuse) that should not be removed
or tampered with. To reduce the risk of fire, electric shock and personal injury, DO NOT attempt to remove, replace, repair or tamper
with the originally supplied plug. If the Fan has stopped functioning, it may be due to the safety device incorporated in this plug.

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig4The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no circumstances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only.

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig4DO NOT USE A THREE-PRONG TO TWO-PRONG ADAPTER. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTRICAL SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.

 

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig5

  • AVOID the use of extension cords, power strips, power taps, outlet style air fresheners or other cord connected device, as these devices may overheat and cause a fire hazard.
  • DO NOT route power cord under rugs, carpets, runners or furniture. This may damage the cord or cause it to overheat creating a fire hazard.
  • ALWAYS place the Fan on a stable, flat, level surface while in operation to prevent the Fan from overturning.
  • NEVER insert or allow fingers or objects to enter grill openings while Fan is in operation or injury and/or damage to the Fan may occur.
  • DO NOT block, cover or obstruct air flow to or from the fan while in operation.
  • DO NOT use this Fan outdoors or near water or wet locations such as a bath tub, pool or hot tub. Use of this Fan in a wet location may create a shock hazard.
  • DO NOT run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
  • NEVER use a single extension cord to operate more than one Fan or other electrical device.
  • DO NOT use this Fan if it has been damaged or is not functioning properly.
  • THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).This Fan is not suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for agricultural buildings.
  • THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).This Fan is not suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical requirements for hazardous locations.

SAVE THESE INSTRUCTIONS

DESCRIPTION

Air King® 12″ (30,4 cm) and 16″ (40,6 cm) Wall Mounted Oscillating Fans offer rotary knob/pull cord speed control, variable oscillation, a permanent split capacitor motor and OSHA-complying front steel mesh grill with a 6 ft (1,8m) 18/3 cord set.

SPECIFICATIONS

Motor …………120V, 60 Hz (12″ 30,4 cm) 120V, 60 Hz (16″ 40,6 cm)
Blade diameter……..12″ ( 30,4 cm) Model 4C630P/9012P 16″ (40,6 cm) Model 4C631Q/9016Q
Speeds…………………3
Control………………….Rotary Knob/Pull Cord Air flow distribution…………90°
Approvals………………ETL Listed. Close mesh Fan Guard meets OSHA requirements.

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig6

SPEED: Speed is controlled by a pull-cord switch. The speed setting is shown by switch knob on front cover. (Off-Low-Med-High-Off)

POWER SUPPLY CORD: Plug power supply cord into a wall outlet (AC 120Volts, 60 Hz).

ASSEMBLY (Figure 1)
  • Put Rear Grill on Motor by aligning the tab on the Rear Grill with the groove on the Motor. (Detail 1)
  • Fully seat Rear Grill on Motor and secure with Plastic Nut turning Clockwise.
  • Slide Blade onto Motor Shaft. (Align groove on blade hub with pin on motor shaft.) (Detail 2)
  • To secure Blade, screw Spinner onto Shaft Counter Clockwise until tight on Blade hub.
  • Snap Front Grill into place.

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig7

INSTALLATION
  • Locate a stud behind wall. If stud cannot be found, special types of mounting anchors are available at your hardware store.
  • Secure Mounting Plate to wall with Screws supplied (#8 X 1 1/4″ Wood Screws). Make sure flange is pointing up as shown in exploded view above.
  • Fan is now ready to hang on Mounting Plate.
OPERATION

VARIABLE OSCILLATION: Pull oscillation knob on the rear of the motor up. Turn fan head to left, right, or straight ahead. Push oscillation knob down and fan will oscillate about the set angle.
VERTICAL ANGLE: To adjust vertical angle, tilt fan head up or down, as desired.

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig8

LASKO-WALL-MOUNTED-OSCILLATING-FANS-Fig9

MAINTENANCE

WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING THE FAN.
WARNING: DO NOT IMMERSE FAN IN WATER!
CLEANING: Use a soft cloth moistened with a mild soap solution, such as liquid dish washing detergent. Dry ALL PARTS COMPLETELY before reassembling. After any maintenance or servicing, COMPLETELY REASSEMBLE unit as described in this instruction manual before reconnecting to the power supply.
CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, etc. as they will damage the Fan. NEVER use ALCOHOL OR SOLVENTS.
LUBRICATION: Precision bearings are sealed at the factory for life and will not require any further lubrication.
STORAGE: Store the Fan, with these instructions, in a cool, dry place.
DISPOSITION: Corrugated packaging materials are recyclable. For environmentally responsible disposal of this product, contact your local waste service provider or visitwww.1800recycling.com®.

Download PDF Link

woi4dwuxvyfy848t34pc

Leave a Reply