Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 12

Levoit Dual 200S Smart Top-Fill Humidifier Manual

Levoit logo

Levoit Dual 200S Smart Top-Fill Humidifier Manual

Levoit Dual 200S Smart Top-Fill Humidifier Manual product img

Specifications

Power Supply24V 1A
Rated Power24W
Water Tank Capacity 

0.79 gal / 3 L

 

 

Max Run Time

Up to 25 hours on low mist setting

 

Note: The humidifier may run for a longer or shorter time depending on the environmental temperature and humidity.

Noise Level≤ 28dB
 

Range

 

107 290 ft² / 10 27 m²

Dimensions7.1 × 7.1 × 11.8 in /

18 × 18 × 30 cm

Weight3 lb / 1.4 kg
Power AdapterInput: 100-240V~

50/60Hz

Output: 24V 1A

Package Contents

  • 1 × Smart Top-Fill Humidifier
  • 2 × Water Filter Sponge (1 Pre-Installed)
  • 1 ×Cleaning Brush
  • 1 ×User Manual
  • 1 × Quick Start Guide

SAFETY INFORMATION

General Safety

  • Only use the humidifier as described in this manual.
  • Place the humidifier and cord so that it will not be knocked over. Do not place near large pieces of furniture or in high-traffic areas.
  • When not in use, turn the humidifier off and disconnect from power by removing the plug from the outlet.
  • Do not use the humidifier in wet environments.
  • Keep the humidifier out of reach of children.
  • Do not open the base or remove the water level sensor for self-servicing.
  • Always unplug your humidifier from the power outlet before cleaning your humidifier or detaching the water tank from the humidifier base.
  • Always make sure to place the humidifier on a flat, level surface before operation.
  • Only fill the water tank with clean water. Never fill the water tank with any other liquids.
  • Do not place the humidifier near sources of heat, such as stovetops, ovens, or radiators.
  • Do not place the humidifier directly on floors, carpets, or rugs.
  • Do not use other items as replacement parts for this product.
  • Do not cover the nozzle while the humidifier is on. Doing so may damage the humidifier.
  • Remove the water tank from the base before moving the humidifier.
  • Do not immerse the humidifier base, power cord, or plug in water.
  • If the humidifier is damaged or is not functioning properly, stop using it and contact Customer Support immediately

Power & Cord

  • Ensure that the plug fits properly into a polarized socket.
  • Do not handle the power cord or plug with wet hands. Keep the plug and power cord away from liquids.
  • Your humidifier has a polarized plug (one prong is wider than the other), which fits into a polarized outlet only one way. This is a safety feature to reduce the risk of electric shock. If the plug does not fit, reverse the plug. If it still does not fit, do not use the plugin that outlet. Do not bypass this safety feature.
  • If the power supply cord is damaged, it must be replaced by Arovast Corporation or similarly qualified persons in order to avoid an electric or fire hazard.
  • Unplugging the power cord will disable the remote control of the humidifier and temporarily disconnect the humidifier from VeSync and other third-party apps.

GETTING TO KNOW YOUR SMART SMART HUMIDIFIER

Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 1

  • A. Nozzle
  • B. Water Tank Cover
  • C. Water Filter Housing
  • D. Water Filter
  • E. Mist Tube
  • F. Water Tank
  • G. Float
  • H. Base
  • I. Display
  • J. Cleaning Brush
  • K. Power Adapter
  • L. Max Water Line (Tank)
  • M. Water Outlet Valve
  • N. Noise Silencer
  • O. Air Outlet
  • P. Max Water Line (Base)
  • Q. Float Brackets
  • R. Transducer
  • S. Secondary Float
  • T. Humidity Sensor
  • U. Feet
  • V. Power Adapter Input
  • W. Air Inlet

Display

Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 2

  • A. Mist Level Button
  • B. No Water Indicator
  • C. Wi-Fi® Indicator
  • D. Timer Indicator Note: The timer must be set in the VeSync app.
  • E. Power Button
  • F. Humidity Level Indicator
  • G. Mist Level Indicator

CONTROLS

Note: You can also control these functions using the VeSync app, as well as additional functions

Levoit Classic 300S Smart Humidifier User Manual fig 3Power Button

  • Press to turn the humidifier on/off.
  • Press and hold for 5 seconds to pair with the VeSync app. See the VeSync in-app instructions for more information.
  • Press and hold for 15 seconds to reset the humidifier. This will restore the humidifier’s default settings and disconnect it from Wi-Fi® and the VeSync app.

Levoit Classic 300S Smart Humidifier User Manual fig 4

Mist Level Button

  • Press repeatedly (or press and hold) to cycle through mist level settings: Auto Mode, Low, Medium, and High.
  • Press during Sleep Mode to turn Sleep Mode off. The humidifier will keep misting on Auto Mode.

No Water Indicator

  • Blinks when there is no water in the tank. After this indicator blinks 10 times, the humidifier will turn o. Refill the tank and properly place it on the base to use your humidifier.
  • Lights up when the water tank is removed. Remains on until the tank is replaced.

GETTING STARTED

  1. Remove all packaging.
  2. Take the water tank off of the base and remove all tape, including any tape on the float.Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 3
  3. Rinse and reassemble all parts before first use
    Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 4
  4. Clean the water tank and water tank cover before first use.
    Note: Check to make sure that the water filter is correctly in place. If not, then rotate the filter clockwise to secure it in place. [Figure 1.2]
    Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 5
  5. Choose a hard, flat location for the humidifier at least 12 inches / 30 cm away from any walls. The surface must be water-resistant. [Figure 1.3]
    Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 6
  6. The mist should be directed away from walls, furniture, bedding, and appliances. [Figure 1.4]
    Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 7

Filling & Refilling

Note: Make sure the water tank is clean before filling.

  1. Remove the water tank cover by holding the nozzle and pulling it upward. [Figure 1.5]
    Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 9
  2. Use the handles to remove the tank from the base. Fill the tank with room-temperature water. [Figure 1.6] Do not fill with hot water.
    Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 10
  3. Replace the water tank cover and place the tank back on the base. [Figure 1.10]
    Levoit Dual 200S Smart Top-Fill Humidifier Manual fig 11
    Note: Make sure the nozzle on the water tank cover is placed over the mist tube, or the humidifier may not work correctly. [Figure 1.11]

Note:

  • We recommend using purified or distilled water to fill the tank.
  • Do not fill past the tank’s max water line.

VeSync App Setup

Note:
The VeSync app is continually being improved and may change over time. If there are any differences, follow the in-app instructions.

  1. To download the VeSync app, scan the QR code or search “VeS
    sync” in the Apple App Store® or Google Play Store.
    Note: For Android™ users, choose “Allow” to use VeSync.
    Cosori Dual Blaze 6.8-Quart Smart Air Fryer Manual FIG 1
  2. Open the VeSync app. If you already have an account, tap login. To create a new account, tap Sign Up.
    Note: You must create your own VeSync account to use third-party services and products. These will not work with a guest account. With a VeSync account, you can also allow your family and friends to control your smart air fryer.
    Note: The VeSync app is continually updated and app features will expand. Note: The VeSync app is continually being improved and may change over time. If there are any differences, follow the in-app instructions. The VeSync app allows you to access additional smart air fryer functions, including those listed below. Note: For Android™ users, choose “Allow” to use VeSync. 2. Open the VeSync app. If you already have an account, tap login. To create a new account, tap Sign Up.
  3. Tap + and select your smart air fryer.
  4. Follow the in-app instructions to set up your smart air fryer.

Wi-Fi Connection:

  • To disconnect Wi-Fi, press and hold the On/Off button for 15 seconds until the Wi-Fi indicator turns off. This will restore the smart air purifier’s default settings and disconnect it from the VeSync app.
  • To reconnect, please follow the instructions in the VeSync app for adding a device.

USING YOUR SMART HUMIDIFIER

Sleep Mode

Sleep Mode changes the humidifier’s mist setting to Auto Mode, turns off the display lights, and turns off the night light.

  • When Sleep Mode is on, you can pressLevoit Classic 300S Smart Humidifier User Manual fig 15to turn the night light on/off. The humidifier will stay in Sleep Mode.

Auto Mode
Auto Mode uses the humidifier’s sensor to automatically adjust the mist level (or turn it off) to maintain a comfortable and healthy level of humidity.

  • Auto Mode automatically adjusts the mist level to maintain 40–50% relative humidity. You can change the target humidity level in the VeSync app.
  • By default, Auto Mode uses Automatic Stop. The humidifier will stop misting when the highest target humidity level is reached. If the humidity drops below the target humidity level, the humidifier will begin misting again.
    • If Auto Mode is selected when the humidity is higher than the target humidity range, the humidifier will not start misting until the humidity lowers.
  • In the VeSync app, you can turn Automatic Stop on/off. If Automatic Stop is off, the humidifier will keep running on a Low mist level when the highest target humidity level is reached.

VeSync App Features

The VeSync app allows you to access additional smart air fryer functions, including those listed below.

Remote Control 

  • Turn the humidifier on/off from your phone.
  • Cycle through mist levels and turn on/off Auto Mode and Sleep Mode from your phone.
  • Turn the display lights and night light on/off from your phone.
  • Customize Auto Mode settings like target humidity and auto-off.

Monitor Humidity Levels 

  • Check current humidity levels in the humidifier’s environment.

Set Timers & Schedules

  • Program individual timers or create a schedule for your smart humidifier.

Third-Party Voice Control

  • Compatible with Amazon Alexa and Google Assistant™ for voice commands.

Note: The VeSync app is continually updated and app features will expand.

Important Tips

Your humidifier must have the correct level of water in the base chamber to work properly. If there is too much water in the base chamber, the humidifier cannot create mist.

Levoit Classic 300S Smart Humidifier User Manual fig 16

  • Never pour water directly into the base chamber. [Figure 3.4] Only add water to the water tank. The humidifier will automatically release the correct amount of water into the base chamber.
  • Avoid moving or shaking the humidifier. [Figure 3.5] This may cause the water tank to release too much water into the base chamber.
  • Before moving the humidifier, turn it off, unplug it, and remove the water tank.
  • If your humidifier doesn’t produce mist correctly, check the max water line to see if there is too much water in the base chamber. Pour out extra water if water is over the max line. [Figure 3.6]
    Levoit Classic 300S Smart Humidifier User Manual fig 17
    Note: The max water line is only for this purpose. Do not pour water into the base chamber.
    Levoit Classic 300S Smart Humidifier User Manual fig 18

CARE & MAINTENANCE

Note:

  • All maintenance should be done on a water-resistant surface, such as a kitchen counter.
  • Change the water daily to avoid bacteria growth.
  • Use a tissue or cloth to clean the nozzle regularly.
  • If not using the humidifier for 1 week or longer, do not leave water inside. Clean and dry the humidifier instead.

Cleaning
You should clean your humidifier every week, and when you’re ready to store it.

Note:

  • Never immerse the base in water or liquid. Do not place any part of the humidifier in a dishwasher.
  • Do not use detergents to clean the humidifier.
  1. Unplug the humidifier.
  2. Remove and rinse the water tank cover. [Figure 4.1]
    Levoit Classic 300S Smart Humidifier User Manual fig 21
  3. Remove and rinse the dust cover if necessary. [Figure 4.2]
    Levoit Classic 300S Smart Humidifier User Manual fig 22
  4. Remove the water tank from the base and pour out any water from the tank and base chamber. [Figure 4.3]
    Note: When pouring out water, hold down the float to ensure that it does not fall out of the base chamber.
    Levoit Classic 300S Smart Humidifier User Manual fig 23
  5. Remove the water filter from the tank by rotating it counterclockwise and lifting it out. [Figure 4.4
    Levoit Classic 300S Smart Humidifier User Manual fig 24
  6. Rinse the tank, water filter, and base chamber with room-temperature water. [Figure 4.5]
    Levoit Classic 300S Smart Humidifier User Manual fig 25
  7. To descale the humidifier:
    • Remove the water filter from the tank by rotating it counterclockwise and lifting it out. [Figure 4.6
      Levoit Classic 300S Smart Humidifier User Manual fig 26
    • Fill the tank with 3 US cups / 710 mL of distilled white vinegar. [Figure 4.7]
      Levoit Classic 300S Smart Humidifier User Manual fig 27

Reassembling

  1. Flip the water tank over and place the noise silencer back into the tank. [Figure 4.20]
    Levoit Classic 300S Smart Humidifier User Manual fig 31
  2. Place the water filter back into the tank and rotate it clockwise to secure it in place. [Figure 4.21]
    Levoit Classic 300S Smart Humidifier User Manual fig 32
  3. Place the float back into the base chamber:
    • Make sure the correct side of the float is facing up. [Figure 4.22]
      Levoit Classic 300S Smart Humidifier User Manual fig 33
    • Insert the smaller prong into the closed side of the float brackets. [Figure 4.23]
      Levoit Classic 300S Smart Humidifier User Manual fig 34
    • Place the larger prong into the open (U-shaped) side of the float brackets.
  4. Place the tank back on the base. Refill the tank, if necessary.
  5. Place the tank properly on the base and place the tank cover on the water tank.

Storing
Follow the cleaning instructions and allow all parts to dry completely 3. Place the float back into the base chamber: before storing. Store in a cool, dry location.

TROUBLESHOOTING

ProblemPossible Solutions
 Humidifier doesn’t turn on, orPlug in the humidifier and turn it on.
Add purified or distilled water to the water tank.
Check to see if the humidifier is in Auto Mode. Depending on
when the humidity level is above the target level.

Little or no mist comes out.
Turn the mist level to a higher setting.
Fill the water tank.
There may be too much water in the base chamber.
Empty the base chamber. Refill the water tank
(not the base chamber) and place the water tank properly onto the base.
Make sure the air inlet on the bottom of the base is not
blocked. The humidifier should not be set on carpet or
other surfaces that may block the air inlet.
Make sure the nozzle is not blocked or clogged.
Make sure the humidifier is on a level surface.
The water temperature may be too low. Turn the mist
level to the highest setting and let the humidifier run for
a while, then adjust to the desired setting.
If the water tank or base was washed with detergent,
rinse thoroughly with clean water to remove any detergent.
Clean the water filter assembly (see page 15) or replace
it with a new one (see page 25).
 Humidifier uses water too quickly.The humidifier uses up water based on the environmental
temperature and humidity. If your environment is cold and/or dry,
the humidifier will run out of water faster.
 Humidifier produces an unusual smell.If the humidifier is new, unplug and rinse all parts,
then place in a cool, dry place for 12 hours.
 (follow the descaling instructions on page 16), and allow
the humidifier to dry.
Clean the water tank and base chamber
(see Care & Maintenance, page 15).
 

White dust appears around the humidifier.

We recommend using purified or distilled water to fill the
humidifier. Avoid using water with high mineral content.
Clean the humidifier (see Care & Maintenance, page 15).
ProblemPossible Solution

Humidifier doesn’t turn on, or
Plug in the humidifier and turn it on.
Add purified or distilled water to the water tank.
Check to see if the humidifier is in Auto Mode. Depending on
when the humidity level is above the target level.
 Little or no mist comes out.Turn the mist level to a higher setting.
Fill the water tank.
There may be too much water in the base chamber. Empty the base

chamber. Refill the water tank (not the base chamber) and place the

water tank properly onto the base.

Make sure the air inlet on the bottom of the base is not blocked.

The humidifier should not be set on carpet or other surfaces that

may block the air inlet.

Make sure the nozzle is not blocked or clogged.
Make sure the humidifier is on a level surface.
The water temperature may be too low. Turn the mist level to the

highest setting and let the humidifier run for a while, then

adjust to the desired setting.

If the water tank or base was washed with detergent, rinse

thoroughly with clean water to remove any detergent.

Clean the water filter assembly (see page 15) or replace it

with a new one (see page 25).

 

Humidifier uses water too quickly.

The humidifier uses up water based on the environmental

temperature and humidity. If your environment

is cold and/or dry, the humidifier will run out of water faster.

 

Humidifier produces an unusual smell.

If the humidifier is new, unplug and rinse all parts, then place in

a cool, dry place for 12 hours.

 

 

(follow the descaling instructions on page 16), and allow the
humidifier to dry.

Clean the water tank and base chamber
(see Care & Maintenance, page 15).
 

White dust appears around the humidifier.

We recommend using purified or distilled water to
fill the humidifier. Avoid using water with high mineral content.
Clean the humidifier (see Care & Maintenance, page 15).

 

VESYNC APP TROUBLESHOOTING

My smart air purifier isn’t connecting to the VeSync app.

  • Make sure your phone has Bluetooth® turned on and is not currently connected to another Bluetooth device.
  • During the setup process, you must be on a secure 2.4GHz Wi-Fi® network. Confirm that the network is working correctly.
  • Try moving your air purifier closer to the router. Your phone should be as close as possible to your air purifier.
  • Your router may need to be at a higher location, away from obstructions.
  • Make sure your air purifier and router are away from appliances (such as microwave ovens, refrigerators, electronic devices, etc.) to avoid signal interference.
  • If you’re using a VPN, make sure it’s turned off while setting up your air purifier.
  • Disable portal authentication for your Wi-Fi network. If portal authentication is enabled, the air purifier will not be able to access your Wi-Fi network, and the setup will fail.

The VeSync app is displaying an incorrect humidity percentage while the humidifier is turned on.

  • The room may be larger than the humidifier’s effective range. Move to a room smaller than 505 ft² / 47 m².
  • Moisture may have built up inside the humidity sensor. Turn off the humidifier and allow the sensor to air dry. Make sure the nozzle is facing away from the sensor so that mist does not settle on the sensor.
FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2.  This device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARRANTY INFORMATION

Product NameLevoit VeSync Core™ 600S Smart True HEPA Air Purifier
ModelLAP-C601S-WUS
For your own reference, we strongly recommend that you record your order ID and date of purchase.
Date of Purchase
Order ID

 

Terms & Policy
Arovast Corporation (“Arovast”) warrants this product to the original purchaser to be free from defects in material and workmanship, under normal use and conditions, for a period of 2 years from the date of original purchase. Arovast agrees, at our option during the warranty period, to repair any defect in material or workmanship or furnish an equal product in exchange without charge, subject to verification of the defect or malfunction and proof of the date of purchase.

There is no other express warranty. This warranty does not apply:
  • If the product has been modified from its original condition;
  • If the product has not been used in accordance with directions and instructions in the user manual;
  • To damages or defects caused by accident, abuse, misuse, or improper or inadequate maintenance;
  • To damages or defects caused by service or repair of the product performed by an unauthorized service provider or by anyone other than Arovast;
  • To damages or defects occurring during commercial use, rental use, or any use for which the product is not intended;
  • To damages or defects exceeding the cost of the product.

Arovast will not be liable for indirect, incidental, or consequential damages in connection with the use of the product covered by this warranty. This warranty extends only to the original consumer purchaser of the product and is not transferable to any subsequent owner of the product regardless of whether the product is transferred during the specified term of the warranty.

This warranty does not extend to products purchased from unauthorized sellers. Arovast’s warranty extends only to products purchased from authorized sellers that are subject to Arovast’s quality controls and have agreed to follow its quality controls. All implied warranties are limited to the period of this limited warranty. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

REFERENCE LINK

https://levoit.com/products/dual-200s-smart-top-fill-humidifier

DOWNLOAD LINK

Levoit Dual 200S Smart Top-Fill Humidifier Manual

Leave a Reply