Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-FEATURE

Honeywell MO08CESWB6 Portable Evaporative Air Cooler User Manual

Honeywell-logo

Honeywell Portable Evaporative Air Cooler User Manual

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Img

SAFETY

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY AND KEEP FOR FUTURE REFERENCE. IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL PREVAIL.

WARNING:

  • DO NOT operate the unit with a damaged plug or loose wall outlet. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • DO NOT cover the air intake and exhaust when in use.
  • DO NOT place objects on or sit on the unit.
  • Always turn off and unplug the unit when cleaning or servicing.
  • DO NOT use the appliance if it is damaged.
  • If service is needed contact an authorized service agent. Unplug the unit when stored or not in use.
  • DO NOT pull or carry the appliance by the power cord.
  • DO NOT pinch the power cord in the door and DO NOT pull it along edges or sharp corners.
  • DO NOT run the power cord under carpeting and rugs.
  • Use caution to prevent tripping on cord.
  • DO NOT use the device in the following cases:
  • Near a fire source
  • In areas where gasoline, paint or other flammable goods are stored
  • In an area where the water can be projected
  • DO NOT touch the plug or the device with wet hands.
  • Basic safety precautions should always be followed when using electrical appliances.
  • This appliance has been manufactured for use in domestic environments and should not be used for other purposes.
  • Only use the installation kit provided to install this unit.DO NOT attempt to extend the Hose or install this unit using other methods other than that shown in this manual. Improper installation will void any existing warranties.
  • DO NOT use an extension cord with this unit.
  • This appliance can be used by children aged from 8 years and above, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Never insert your fingers or rods into the air outlet. Take special care to warn children of these dangers.
  • The manufacturer is not liable for injury caused to persons or property damage due to non-compliance with maintenance instructions and improper use of the appliance.
  • The appliance shall be installed in accordance with national wiring regulations. The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
  • Children should be supervised to ensure that they do not play with the appliance.

USER TIPS

Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is dehumidified and cooled while a flexible Hose sends heat outside. The air conditioner includes a window venting kit. No permanent installation is needed. The unit is easy to move from room to room and offers a truly flexible air conditioning solution.
Auto Evaporation System – The unit automatically evaporates the condensate through the Hose. There is no need to empty the drainage tank except in very humid conditions. Read and follow the instructions carefully. To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig1

Important:
Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize. Manually adjust the air vent located at the front of the unit to adjust the direction of air flow.

  • Follow installation instructions to set up the unit.
  • Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.

PARTS DESCRIPTION

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig2

  • Control Panel (Incl. Signal Receptor)
  • Hose Connector
  • Air Outlet
  • Power Supply Cord
  • Handle
  • Remote Control
  • Casters
  • Lower Rubber Drain Plug (Air Conditioning Mode)
  • Dust Filter
  • Upper Rubber Drain Plug (Dehumidifier Mode)
  • Back Grill

INSTALLATION

It is important that the installation instructions below are followed for successful installation of this Portable Air Conditioner. Please call Customer Support if you have any difficulties or queries regarding these installation procedures.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig3

Installation Kit:

  • Window Bracket Kit (1 Set)
  • Hole Cover (1 Piece)
  • Window Bracket Panel Adapter (1 Piece)
  • Exhaust Hose (1 Piece)
  • Exhaust Hose Connector (1 Piece)

Installation Steps:
Exhaust Hose Connector, Exhaust Hose and window bracket panel adapter are pre-assembled inside the package.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig4

  • The Window Brackets are approximatley 19.7″ (50 cm) each, allowing you to install to windows and balcony doors of different heights or width.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig5

To install the window bracket to the window frame, you need to adjust the height or width of the window bracket by extending the length according to the height or width of the window. When the length is set, tighten the Adjustable Knobs (preinstalled on the window bracket) to ensure the window bracket is secured in the desired position. Use one or all two pieces of window bracket as needed.

Note: After setting the window bracket to the size of your window, please remove it from the window and follow the instructions below.

  • Connect the Exhaust Hose to the Exhaust Hose Connector on back of the unit. Slide-in the Exhaust Hose Connector. Press the Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig7 button to lock the Exhaust Hose Connector in place.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig6

  • Connect the window bracket to the window bracket panel adapter. Slide-in the window bracket panel adapter then rotate clockwise until it is locked in place.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig8

  • Connect the window bracket to the window.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig9

  • The Portable Air Conditioner is now ready to use.

IMPORTANT: Do not replace or lengthen the Exhaust Hose as this could cause the unit to malfunction.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig10

WARNING: Any warranties included with this product will be voided if an extra extension Hose is added to the originally provided installation kit or if the installation is performed differently than the manufacturer’s instructions, without proper consultation. Please contact Customer Support for help with installation procedures if needed.

  • The supplied Hose has a diameter of 5.5″ (14 cm) and can be extended from 12″ to 47″ (30 cm to 120 cm).
  • Do not bend (to the extent shown below) the Hose. A bent Hose will block exhaust air and cause the unit to malfunction or shut-off.
  • Make sure the back of the unit is at least 20″ (50 cm) away from the wall. Do not place the unit in front of curtains or drapes as this could obstruct the airflow.

USE & OPERATION

CONTROL PANEL

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig11

  • Power Control / Standby Mode
  • Timer Light
  • Timer / Temperature Set Controls
  • Timer Control
  • Mode Control
  • Filter Alert
  • Warning Light (when flashing)
  • Fan Speed Control
FUNCTION BUTTONS

POWER CONTROL Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig12
The Power Control turns the unit on and off. When the unit is plugged in, this button lights up indicating it is in a Standby Mode ready to be switched on anytime.

TIMERCONTROL Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig13
While the unit is turned on, press the timer button then press the + or – to select the number of hours you would like the unit to continue to run. The unit will turn off automatically.

AUTO TURN OFF:
While unit is running, press Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig13 the button and the display will flash. While the display is flashing, press the + or – button to select the number of hours you want the unit to turn OFF automatically.

AUTO TURN ON:
When unit is in a standby mode (plugged in with power light on), then press the + or – button to select the number of hours until you want the unit to automatically start running.

TEMPERATURE / TIMER SET CONTROLS

  • Used for adjusting the timer and thermostat.
  • The default display is setting temperature.
  • In cooling mode, when + or – button is pressed, the set temperature is displayed and may be adjusted. After 10 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode. The time is adjustable between 1 – 24 hours.

Note: By pressing both + or – buttons at the same time, the display will toggle between Celsius(°C) and Fahrenheit(°F).

WARNING LIGHT
Condensation may accumulate in the unit. If the internal tank becomes full, the Power Control light will flash and the unit will not operate until the unit has been drained (refer to Water Condensation Drainage).

MODE CONTROL Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig14
Settings: Air Conditioning, Dehumidifying, Fan. The corresponding indicator light will illuminate to indicate the current mode setting.

  • Air Conditioning ModeHoneywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig15
    Adjust fan speed and air temperature to suit your desired comfort level. Temperature setting range is 16°C – 32°C (61°F – 89°F).
  • Dehumidifying ModeHoneywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig16
    Air is dehumidified as it passes through the unit, without being in full cooling mode. If room temperature is higher than 25°C (77°F) fan speed can be adjusted; otherwise fan speed is preset to LOW.

Note: If the unit will be used mainly as a dehumidifier, do not connect the Hose. Continuous
drainage is then necessary (refer to Continuous Draining for Dehumidifier Mode).

  • Fan Mode Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig17
    For air circulation without air conditioner cooling.

FAN SPEED CONTROL Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig18
Applicable for model MO08 Series: High and Low. Applicable for model MO10 Series: High, Medium and Low.

FILTER ALERT Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig19
When the Filter Alert Light is ON, it is time to clean the filter. Switch the air conditioner OFF and carefully remove the filter from the unit and clean. Replace the filter and switch ON the air conditioner. The Filter Alert Light should not be illuminated until the filter requires cleaning again. The frequency of filter cleaning depends on room environment conditions. Some rooms may require changing more frequently than others

REMOTE CONTROL

The functions work the same as the Portable Air Conditioner’s Control Panel. All key functions can be accessed from the remote control.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig20

Note:
Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with + and – pointing in the proper direction according to the polarity markings.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig21

Caution:

  • Use only two AAA or IEC R03 1.5V batteries.
  • Remove the batteries if the remote control is not in use for a month or longer.
  • All batteries should be replaced at the same time, do not mix with old batteries.
  • Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
  • Properly dispose of used batteries.

This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions:  this device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation.

Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

CLEANING & MAINTENANCE

Appliance Maintenance:

  • Turn off the appliance before disconnecting the power supply.
  • Only clean the appliance with a soft dry cloth.

Dust Filter Maintenance:
The dust filter is to be cleaned every two weeks to maintain air cooling efficiency. Please follow the below instructions for cleaning the dust filters:

  • Turn off the appliance and remove the upper and lower dust filters.
  • Rinse it in lukewarm water. After cleaning, dry in a shaded and cool place, then reinstall.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig22

End of Season Storage & Maintenance:
If the appliance will not be used for a long time, follow these steps:

  • Be sure to drain the left-over water condensation. Remove the lower drain plug and use a shallow pan to collect the water (make sure to replace the drain plug when finished).
  • To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.
  • Turn off and unplug the air conditioner from the power supply.
  • Remove the dust filter and clean with water. Dry the dust filter and then reinstall.
  • Disconnecting the Window Installation Kit:
  • Remove the Hose from the unit by rotating anti-clockwise to unlock the knob mechanism then sliding out.
  • Remove the window bracket panel adapter from the window bracket by rotating anti-clockwise then pulling away.
  • It is recommended to store the Window Kit parts in a bag together with the Remote Control and placing them together with the air conditioner unit.
  • If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all parts of the Window Kit are dry before storage.
  • Cover the air conditioner with a cloth/plastic bag before storage, to protect from dust and scratches collecting on the surface of the unit.
  • It is recommended to coil the power cord before storing to ensure the cord is protected from bents and creases.
  • Store the air conditioner in a cool, dry place, away from direct sunlight.

WATER CONDENSATION DRAINAGE

When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (the Power Control button flashes with a red light). This warning light indicates that the water condensation needs to be drained using the following procedures:

Manual Draining for AC & Dehumidifier Mode

Water may need to be drained in high humidity areas.

  • Unplug the unit from power source.
  • Place a shallow pan under the lower rubber drain plug. See diagram.
  • Remove the lower rubber drain plug.
  • Water will drain out and collect in the shallow pan.
  • After the water is drained, replace the lower rubber drain plug firmly.
  • You can now turn on the unit.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig23

TROUBLESHOOTING GUIDE

The following troubleshooting guide addresses the most common problems. If problems persist, call customer support. Unplug and disconnect the appliance from the power source before attempting to troubleshoot.

Honeywell-Portable-Evaporative-Air-Cooler-User-Manual-Fig24