OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-prduct-img

OMRON PM800 Total Power + Heat™ TENS Unit User Guide

omron logo

OMRON PM800 Total Power + Heat™ TENS Unit User Guide

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-prduct-img

HOW THE DEVICE WORKS

How does the device work?
The OMRON Total Power + Heat is an innovative device that relieves chronic, acute*, and arthritic pain through the pain relief of TENS and the soothing comfort of heat. Physical therapists have been using the combination of heat and TENS for decades. Scientific theory suggests that TENS therapy may work in several ways:

  1. Gentle electrical pulses move through the skin to nearby nerves to block or shut out the pain message from ever reaching the brain from the source of the pain.
  2. Gentle electrical pulses increase the production of the body’s natural painkillers, such as endorphins.
  3. Blood circulation improves as muscles contract and relax with the flow of the electrical stimulation.
    * Acute pain refers to sore or achy muscles due to strain from exercise or normal household and work activities.

KNOW YOUR DEVICE

Contents

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-1

Part Names and Functions on the Device

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-2

< Screen >

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-3

< Cord with Pads >

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-4

PREPARATION

Charging

  • If you are using the device for the first time or the device has not been used for more than three months, charge the battery to full.
  • Once fully charged, the battery will last for approximately four 30-minute uses on average. Once the battery has been depleted, it takes about five hours to charge.
  • Recommended temperature during battery charging: 41 °F to 95 °F (+5 °C to +35 °C)
  1. Connect the AC adapter plug to the AC adapter jack on the device
    OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-6
  2. Plug the AC adapter into an electrical outlet.

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-7

CAUTION

  • DO NOT use any AC adapter other than the one provided in the packaging of this device.

Note:

  • Make sure not to place your device in a location where it is difficult to plug and unplug the AC adapter.
  • When charging the battery, the “Battery” symbol flashes on the screen.
    OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-8
  • When fully charged, the symbol (OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-9 ) will flash shortly on the screen, then power will be turned off. Press the OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-10 button to check that the battery is fully charged

Once the battery is fully charged, unplug the power plug, then unplug the AC adapter plug

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-11

  • Unplug the AC adapter when using the device.

“Battery” symbol
Note: While the battery is charging, the device does not work

DisplayDescription
 

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-9

The battery charge is full.
 

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-16

The battery charge is about half full.
 

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-17

The battery is close to low.
 

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-18

The battery is depleted.

Battery Life
Your device will last up to four 30-minute uses per charge, depending on the use and the storage condition.

Battery lifespan
Battery life depends on usage and storage conditions. When fully charged, the rechargeable battery will last for up to 500 uses when used one time per day in normal temperatures. See section 8 for the recommended temperature during battery charging.

Assembling Steps

Prepare pads
Attach the cord plug into the bottom left side of the device. Place the pads (dark side up) onto a flat surface.

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-12

Note: Do not turn the power on before placing the pads on the body

CAUTION

  • Before use, inspect the cord with pads for open wires or any damage. If damaged, DO NOT use it and replace it immediately. The damaged cord with pads may cause skin burns or a fire.

Assemble gels.
For first-time use, remove the gels from the sealed plastic bag. Note: The pads and the gels must be used together for safety and effectiveness. Clean and dry the affected area so it’s free of all lotions/oils/sweat.

Place gels onto the pads.
Each gel has two plastic films. Remove the non-printed side of plastic films and place gels squarely onto the dark side of the pads. Make sure the gel lays evenly and securely with no bubbles, bending or missing pieces. Check for damage and check the adhesion before each therapy session. The “SKIN” printed side of plastic films are on top.

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-13

STORING THE PADS ON THE PAD HOLDER

OMRON-PM800-Total-Power +-Heat™-TENS-Unit-User-Guide-fig-14

Remove the plastic film and place the adhesive side of the gel on either side of the pad holder.

REFERENCE LINK

Leave a Reply