SPECIFICATIONS

24 Volt A.C. Heat Anticipator:           0.20 to 1.2 Amp. Max.
Electrical Rating:                                 24 to 30 Volts A.C. Cold Anticipator: 0 to 1.0 Amp. Max

SELECTING THERMOSTAT LOCATION

  1.  Locate it about 5 ft. above the floor with a free flow of air.
  2.  Install it on a partitioning wall, not on an outside wall.
  3. Never expose it to direct light or radiation from lamps, sun, fireplaces, etc.
  4.  Avoid locations close to doors that lead outside, windows, or adjoining outside walls.
  5.  Avoid locations close to radiators, warm air registers, or in the direct path of heat from them.
  6.  Make sure there are no pipes or duct work in that part of the wall chosen for the thermostat location.
  7.  The living or dining room is normally a good location, provided there is no cooking range or refrigerator on opposite side of wall.

INSTALLATION

  1. Remove cover from thermostat by pulling outward. Pull thermostat wires through small holes beside terminal screws on thermostat base and connect wires to proper terminal screws per wiring diagrams.
  2.  The thermostat must be level to assure optimum performance. Place level on top of thermostat base and mark hole locations for mounting screws.Push excess wire into wall or switch box and plug up hole to prevent drafts from affecting thermostat operation.

WIRING DIAGRAMS

Heating Systems LUXPRO-PSM200SA-Versatile-Deluxe-Low-Voltage-Thermostat-User-Manual-Image

  • If replacing a Honeywell TM-11,tape off wire “R”; connect wire “B” to terminal “RH.”
  • If replacing a Honeywell thermostat with a clock wire “C,” tape off wire “C”

Cooling SystemsLUXPRO-PSM200SA-Versatile-Deluxe-Low-Voltage-Thermostat-User-Manual-Image-1

Heating/Cooling Systems 4- or 5-Wire with One Transformer

LUXPRO-PSM200SA-Versatile-Deluxe-Low-Voltage-Thermostat-User-Manual-Image-2

TYPICAL HOOKUP FOR 2-WIRE 24V HEATING SYSTEM AND MILLIVOLT SYSTEMLUXPRO-PSM200SA-Versatile-Deluxe-Low-Voltage-Thermostat-User-Manual-Image-4

TYPICAL HOOKUP FOR 3-WIRE HEAT SYSTEM IF THIRD WIRE IS FAN WIRE

LUXPRO-PSM200SA-Versatile-Deluxe-Low-Voltage-Thermostat-User-Manual-Image-5

TYPICAL COOLING AND HEATING SYSTEM (4-WIRE)LUXPRO-PSM200SA-Versatile-Deluxe-Low-Voltage-Thermostat-User-Manual-Image-6

TYPICAL COOLING AND HEATING SYSTEM (5-WIRE)LUXPRO-PSM200SA-Versatile-Deluxe-Low-Voltage-Thermostat-User-Manual-Image-7

WARRANTY

LUX Products Corporation will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions.  Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit. Some above exclusion may not apply to you.