Topens TC188 Universal Wireless Wired Keypad User Manual
NOTE: Please read this manual thoroughly before installation and programming.
NOTE: The keypad is universal for both wireless and wired application. You can try the wired application if the interference affect the remote control range or the wireless code is not matching your gate opener. You must use external wired power source to power up the keypad if you choose the wired application.
Specifications
Power input: 9VDC carbon battery for wireless application or 9-24VAC/DC for wired application
Frequency: 433.92MHz
Rated output contact for wired application: 1A/120VAC, 1A/24VDC
Installation of the Battery
NOTE: A 9VDC carbon battery is required to power the keypad unless an external power supply such as the gate openers’ power source is used. A battery has been installed in the keypad in factory. You need to change the battery if the wireless signal becomes weak. Low voltage wire from the external power source must be connected to the 9-24VAC/DC power in terminals on the keypad control board if the battery is not installed.
Step 1: Remove the screw from the bottom of the keypad and separate the installing baseplate from the back cover.
Step 2: Remove the screws to separate the back cover from the middle main functional part.
Step 3: Install 9VDC carbon battery.
Installation of the Keypad
Step 1: Remove the screw from the bottom of the keypad and separate the installing baseplate from the back cover.
Step 2: Install the baseplate to the wall or the post with the screws included in the kit.
Step 3: Install the baseplate back to the back cover of the keypad.
Universal Control Board Connection for Wired Application
You can connect the 1# and 2# terminals of the keypad to the terminals for push button of the gate opener. No matter the polarity. And then you can connect the 3# and 4# terminals of the keypad to the 9-24VAC/DC auxiliary output terminals of the gate opener. No matter the polarity.
Programming the Keypad
NOTE: There are two kinds of codes while programming: Master code and Entry code. The master code is used to program the keypad.The entry code is used to activate the keypad to control the gate opener. You can program the temporary codes and the permanent entry codes according to your needs. The use number of times of the temporary entry codes can be programmed at the same time.
NOTE: Max. 32 permanent entry codes and 32 temporary codes can be programmed to the keypad.
NOTE: All codes should be 4 digits in length. Factory default master code is 9999.
Program New Master Code
SET 4 digits Old Master Code SET 01 SET 4 digits New Master Code SET 4 digits New Master Code SET
Add New Permanent Entry Code
SET Master Code SET 02 SET Entry Code SET Entry Code SET
Change Permanent Entry Code
SET Master Code SET 03 SET Old Entry Code SET New Entry Code SET New Entry Code SET
Add New Temporary Entry Code
SET Master Code SET 04 SET Entry Code SET 2 Digits Use Number of Times SET
Delete Single Entry Code (Permanent Entry Code or Temporary Entry Code)
SET Master Code SET 05 SET Entry Code SET
Delete All Temporary Entry Codes
SET Master Code SET 66 SET
Delete All Entry Codes (Include Permanent Entry Codes and Temporary Entry Codes)
SET Master Code SET 77 SET
Program the Keypad to the Gate Opener (Wireless Application)
Step 1: Input the entry code of the keypad when it’s in standby mode.
Step 2: Press and release the remote control programming button (CODE SW button, LNSW button, Learn button, etc.) on the gate opener control board, the CODE LED (REM LED, LEARN LED, LCD, etc.) will be ON or indicate the programming display.
Step 3: Press the A or B key of the keypad two times in 2 seconds, between the two times HOLD ON FOR A MOMENT until the code transmission completed, the CODE LED (REM LED, LEARN LED, LCD, etc.) will flash for 3 seconds and then to OFF or standby display. Now the keypad has been programmed to the gate opener successfully.
Use the Keypad to Operate the Gate Opener
You can input the valid entry code and then press key A or key B which has been programmed to the control board to operate the gate opener. You don’t have to input the entry code again within 3 seconds after the key A or key B is activated.
Reset the Master Code of the Keypad
There is a reset button on the back of the control panel of the keypad. You can hold and press the button for 4 seconds until the blue backlights flash quickly and the buzzer beeps 2 long sound. The master code has been restored to factory default value: 9999.