You are currently viewing Aube TH115-A-120S 7-Day Programmable Thermostat Guide

Aube TH115-A-120S 7-Day Programmable Thermostat Guide

Aube logo

Aube TH115-A-120S 7-Day Programmable Thermostat Guide

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-prduct-img

Description

Aube’s TH115 programmable thermostats have three temperature control modes

A mode:

  • controls the ambient air temperature

F mode:

  • controls the floor temperature using an external temperature sensor

AF mode: 

  • controls the ambient air temperature
  • maintains the floor temperature within desired limits using an external temperature sensor

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-1

  1. Place the switch on Standby to cut power to the heater when not in use (e.g., in the summer). This will not affect the time and temperature settings.
  2. If your thermostat is installed on a power base equipped with ground fault protection, to reset the ground fault protection, switch the thermostat to Standby and back to On.
  3. The thermostat displays the percentage of heating time required to maintain the desired temperature. For example, Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-4 is displayed when heating is activated 40 percent of the time.
    Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-2
  4. GFI appears when the ground fault protection has tripped.

Configuration

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-3

Some thermostat configurations can be modified via switches on the back of the faceplate (control module). Default (factory) settings are inside the gray cells.

#ConfigurationsUPDN
1Display format°F / 12 h°C / 24 h
2Early Start aEnableDisable
3Temperature control mode bFAF
  • a. Early Start can be used in Automatic mode only. When this function is enabled, the thermostat calculates the optimal time to start heating to obtain the desired temperature by the set time. The thermostat re-assesses the start time daily based on the previous day’s results.
  • b. To select the F mode, place the switch in the F position. To select the AF mode, place the switch in the AF position and ensure that the remote temperature sensor is connected to the thermostat. To select the A mode, place the switch in the AF position and ensure that the remote temperature sensor is NOT connected to the thermostat.

Installation

  1. Refer to the installation instructions for the power base.
  2. Insert the tabs at the top of the control module in the slots at the top of the power base.
  3. Secure the control module using the captive screw underneath the base.

Clock and Day Setting

  1. Press the Hour button to set the hour.
  2. Set the Min button to set the minutes.
  3. Set the Day button to set the day.
  4. Press Mode/Ret to exit.

Daylight Savings Time 
The thermostat can automatically re-adjust its clock at Daylight Savings Time changeover. When this function is enabled (On), the thermostat switches to Daylight Savings Time on the second Sunday of March and to normal time on the first Sunday of November. NOTE: The function is disabled (default setting) when the clock loses its setting

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-6

  1. Press the Day button (3 seconds) until DLS appears on the screen.
  2. Press the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 toggle between On (enabled) and Off (disabled).
  3. Press the Day button briefly. The year setting is displayed.
  4. Press the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 to set the current year.
  5. Press the Day button briefly. The month setting is displayed.
  6. Press the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 to set the current month.
  7. Press the Day button briefly. The date setting is displayed.
  8. Press the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 to set the current date.
  9. Press Mode/Ret to exit.

Backlight
The display illuminates for 12 seconds when the backlight button is pressed. When either of the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7

buttons is pressed, the display also illuminates for 12 seconds. The setpoint temperature appears for 5 seconds, then the actual (measured) temperature is displayed.

Temperature Adjustment

Setpoint Temperature
The thermostat normally displays the actual (measured) temperature. To view the setpoint, press one of the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 buttons once. The setpoint will appear for the next 5 seconds. To change the setpoint, press one of the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 buttons until the desired temperature is displayed. To scroll faster, press and hold the button.

Preset Temperatures

The thermostat has 3 preset temperatures:

  • Comfort temperature Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8
  • Economy temperature Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-9
  • Vacation temperature Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-10

To use a preset temperature, press the corresponding button. The corresponding icon Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-11 will be displayed. The following table shows the intended use and the default setting of each of the preset temperatures.

IconIntended useA/AF modesF mode
 

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8

Comfort

(when at home)

21 °C (70 °F)28 °C (82 °F)
Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-9Economy

(when asleep or away from home)

17 °C (63 °F)20 °C (68 °F)
Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-10Vacation

(during prolonged absence)

10 °C (50 °F)10 °C (50 °F)

To store a preset temperature:

  1. Set the desired temperature using the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 buttons.
  2. Press and hold the corresponding button until the corresponding icon is displayed.
Floor Temperature Limits (AF mode only)

NOTE: To avoid damaging your floor, follow your floor supplier’s recommendations regarding floor temperature limits. The minimum and maximum floor temperature limits are 5 °C (41 °F) and 28 °C (82 °F) by default. To modify these limits, proceed as follows:

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-12

  1. Switch the thermostat to Standby.
  2. Press and hold theAube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8button.
  3. Switch the thermostat back to On.
  4. Release the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8 button when the minimum temperature limit (FL:LO) appears.
  5. Set the minimum temperature limit using the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 buttons.
  6. Press the button to display the maximum temperature limit (FL:HI).
  7. Set the maximum temperature limit using the Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 buttons.
  8. Press Mode/Ret to exit.

Modes of Operation

The thermostat has 3 modes of operation.

Automatic Mode
The thermostat follows the programmed schedule. To place the thermostat in this mode, press Mode/Ret until is Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-13 displayed. The data of the current schedule period are also displayed.

Temporary Bypass
If you modify the setpoint temperature (by pressing the  Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-14 button) when the thermostat is in automatic mode, the new temperature will be used until the beginning of the next period. Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-13 flashes during the bypass. You can cancel the bypass by pressing Mode/Ret.

Programmed Schedule
The schedule consists of 4 periods per day which represents a typical week day. You can program the thermostat to skip the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the weekend.

PeriodDescriptionAssociated temperature setting
 

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-15

Wake-up 

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-16Away from homeAube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-9
Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-17Return home 

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-17

 

SleepAube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-9

The Comfort (Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8 ) temperature is used in periods 1 and 3 and the Economy ( Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-9) temperature is used in periods 2 and 4. For example, when the period changes from 1 to 2, the setpoint automatically changes from Comfort ( Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8) temperature to Economy (Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-9 ) temperature. You can have a different program for each day of the week; i.e., each period can start at a different time for each day of the week. The thermostat has been programmed with the following schedule.

PeriodSettingMOTUWETHFRSASU
 

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-15

 

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8

6:006:006:006:006:006:006:00
Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-16Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-98:308:308:308:308:30–:––:–
Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-17 

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8

17:0017:0017:0017:0017:00–:––:–
Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-17

 

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-923:0023:0023:0023:0023:0023:0023:00

 

To modify the schedule:
  1. Press Pgm to access the programming mode. Period 1 is selected.
  2. Press Day to select the day to program (hold for 3 seconds to select the entire week).
  3. Press Hour and Min to set the start time of the selected period, or press Clear if you want to skip the period (–:– is displayed). NOTE: If you intend to use only 2 periods, set periods “1 and 4” or periods “2 and 3”. Early Start will not work if you set periods “1 and 2” or periods “3 and 4”.
  4. Press Pgm to select another period, or press Day to select another day. Then repeat step 3.
  5. Press Mode/Ret to exit the programming mode.

NOTE:
If no button is pressed for 60 seconds, the thermostat will automatically exit the programming mode.

Manual Mode
The programmed schedule is not used. The temperature must be set manually. To place the thermostat in this mode:

  1. Press Mode/Ret until Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-19 is displayed.
  2. Set the temperature using theAube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-7 ,Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-8 or Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-9 button

Error Messages

  • Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-20The measured temperature is below the thermostat’s display range. The heating is activated.
  • Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-21The measured temperature is above the thermostat’s display range. The heating is deactivated.
  • Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-22Verify the thermostat and sensor connections.

Technical Specifications

  • Power supply: Refer to the power base’s installation guide.
  • Display range: 0 °C to 70 °C (32 °F to 158 °F)
  • Ambient setpoint range (A/AF modes): 5 °C to 30 °C (40 °F – 86 °F)
  • Floor setpoint range (F mode): 5 °C to 40 °C (40 °F – 104 °F)
  • Floor limit range (AF mode): 5 °C to 40 °C (40 °F – 104 °F)
  • Display resolution: 0.5 °C (1 °F)
  • Operating temperature: 0 °C to 50 °C (32 °F to 120 °F)
  • Storage temperature: -20 °C to 50 °C (-4 °F to 120 °F)
  • Heating cycle length: Refer to the power base’s installation guide
  • Data backup: In the event of a power failure, most settings are saved. Only the time must be re-adjusted if the power failure lasts more than 6 hours. The thermostat will return to the mode that was active before the power failure.

Warranty

Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for three (3) years from the date of purchase by the consumer. If at any time during the warranty period, the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube’s option). If the product is defective,

  1. return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or
  2. contact Aube. Aube will determine whether the product should be returned, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage that occurred while the product was in the possession of a consumer. Aube’s sole responsibility shall be to repair or replace the product within the terms stated above.

AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.

Some provinces, states, or regions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY.

Some provinces, states, or regions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from one province, state, or region to another.

Parts

  1. One (1) power base
  2. Two (2) screws
  3. Four (4) solderless connectors for copper wires

NOTE:
Special CO/ALR solderless connectors must be used for connecting aluminum conductors.

Guidelines

Turn off power to the heating system at the main electrical panel to avoid electrical shock. The installation should be carried out by an electrician. NOTE: This power base must be used with a thermostat operating on 15-minute cycles

  • High-voltage thermostats must be installed onto an electrical box.

The following guidelines are not necessary for floor heating applications:

  • For a new installation, choose a location about 1.5 m (5 ft) above the floor and on an inside wall.
  • The thermostat must be installed on an inside wall facing the heating system.
  • Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes.
Procedure
  1. Connect the power base wires to the power supply and load using solderless connectors for copper wires (figure 1).
  2. For floor heating applications, insert the floor sensor wires through one of the two holes below the terminals (figure 2) and connect the wires to terminals 3 and 4 (no polarity). NOTE: The wires must run alongside the terminals and not go over them. The wire must not cross any heating wires nor be placed directly on a heating wire or adjacent to it. For best performance, the sensor probe should be centered between the wires in the mat. WARNING: This power base does not have a built-in ground protection device. Therefore, for floor heating applications, you must install a separate ground protection device at the main electrical panel. Contact your Aube-authorized representative if you need a thermostat with a built-in ground protection device.
  3. If you wish to use a remote controller such as the CT240 or CT241, insert the cable (use 18 to 22-gauge flexible wires) into one of the two holes available below the terminal board and connect to terminals 1 and 2 of the base (figure 2).
  4. Push the excess length of the high-voltage wires back into the electrical box.
  5. Secure the power base to the electrical box using the provided screws.
  6. If necessary, set the configuration switches on the control module (refer to the control module user guide).
  7. Install the control module onto the base.
  8. Apply power to the heating system.

Aube-TH115-A-120S-7-Day Programmable-Thermostat-Guide-fig-23

Technical Specifications

ModelSupplyMax. LoadPowerWiring
120S120 VAC, 50/60Hz16.7 A2000 W4 wires / single pole
240S240 VAC, 50/60Hz

208 VAC, 50/60Hz

16.7 A4000 W

3475 W

4 wires / single pole
240D240 VAC, 50/60Hz

208 VAC, 50/60Hz

15 A3600 W

3120 W

4 wires / double pole
  • Storage: -4°F to 120°F (-20°C to 50°C)
  • Remote controller input (ECONO): requires a dry contact
  • Size (H • W • D): 4.89 x 2.76 x 0.91 in. (124 x 70 x 23 mm)

REFERENCE LINK

https://www.aartech.ca/aube

Leave a Reply