Foreword
The Non-Contact Infrared Body Thermometer Operating Instructions intend to provide the necessary information for the proper operation of the VNT275US thermometer. General knowledge of the Non-Contact Infrared Body Thermometer and an understanding of the features and functions of the VNT275US thermometer are prerequisites for proper use. The Non-Contact Infrared Body Thermometer is a medical device and can be used repeatedly for 1 year. Please read the manual before using the device, if you do not fully understand these instructions for use, do not use the thermometer.

Indications for Use

The Non-Contact Infrared Body Thermometer is a non-sterile, reusable thermometer intended to be used for the intermittent determination of human body temperature by consumers of all ages in a home-use environment (such as home settings or places of business as an employee screening tool), in no touch mode, with the forehead as the measurement site.

Safety Information
This device may only be used for the purposes described in these instructions. The manufacturer cannot be held liable for damage caused by the incorrect application.

Important Safety Instructions:
  • The Non-Contact Infrared Body Thermometer is intended to be used by consumers in a home-use environment (such as home settings or places of business as an employee screening tool).
  • Keep out of reach of children under 12 years.
  • NEVER use the thermometer for purposes other than those for which it has been intended. Please follow the general safety precautions when using on children.
  • NEVER immerse the thermometer in water or other liquids (not waterproof). For cleaning, please follow the instructions in the “Care and Cleaning” section.
  • DO NOT store this thermometer in temperatures below -4°F or over 131°F (extremes below -20°C or over 55°C) or in excessive humidity (up to 93% non-condensing relative humidity).
  • Let the thermometer and the individual being measured acclimate to the temperature of the room for 30 minutes during which the measurement will be taken.
  • Before using, allow the thermometer to remain in the room in which it will be used for 30 minutes. The room temperature should be between 59°F – 95°F (15°C to 35°C).
  • The individual being measured should be indoors for 20 minutes before taking a measurement, as the external temperature can impact skin temperature.
  • In the event that you can’t follow the ambient acclimation guidance due to using this device as a screening tool, the reading displayed may shift up or down as a result of the temperature subjects are coming from compared to the temperature they are being measured in. If that is the case, judge individuals against each other, and any individual that is reading 1.5°F (0.8°C) higher or lower than the normal, should be measured again with the following acclimation.

Overview

Description of Non-Contact Infrared Body Thermometer

  • Device principle and introduction: The Non-Contact Infrared Body Thermometer is a hand-held, reusable, battery-operated device, which can measure human body temperature using the forehead as the measurement site (the skin temperature on one’s forehead.) The operating principle is based on Infrared (IR) Sensor technology. When measuring, the IR Sensor acquires infrared energy from the target forehead. Taking into account the ambient temperature, the thermometer turns the signal from the IR Sensor to a digital value and displays it on the LCD.
  • Description of Controls, Indicators, and Symbols

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 1

Figure 1: VNT275US Non-Contact Infrared Body Thermometer

  1. LCD display
  2. Battery Cover
  3. On the (Trigger) button
  4. SET button
  5. MEMO button
  6. MODE button
  7. IR sensor

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 2

  1. Surface mode
  2. Body mode
  3. Digital Display
  4. Smile or Cry Indicator
  5. Battery indicator
  6. The voice on/off indicator
  7. Memory number
  8. °F
  9. °C
  10. Memory

Equipment Symbols

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 3Caution 

 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 9

Operating atmospheric pressure
 

 

 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 4

Nonsterile packaging 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 10

Recyclable
Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 5Consult Instructions for Use 

 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 11

Compliance with WEEE Standard
Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 6

 

Operating Temperature 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 12

BF Type applied part
 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 7

 

 

 

Operating Humidity 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 13

Manufacturer
IP22IP22: Protected against solid foreign objects greater than 12.5 mm in diameter and dripping water when tilted at 15º

 

Technical Specifications

Measurement unit°C/°F
Operating modeAdjusted mode (Body mode) Direct mode (Surface mode)
Measuring siteForehead
Reference body siteAxillary
Measuring rangeBody mode: 93.2°F~109.2°F/34.0°C -42.9°C

Surface mode: 32°F~212°F/0°C~100°C

Laboratory accuracyBody mode:

±0.4°F/±0.2°C for the range 95°F~107.6°F/ 35.0°C -42.0°C

±0.5°F/±0.3°C outside of that range Surface mode:

±3.6°F/±2.0°C

Display Resolution0.1°F/0.1°C
Fever InSight (Three-Color Backlight)96.2-99.2°F or 35.7-37.3°C: Green Backlight (Normal); 99.3-101.1°F or 37.4-38.4°C: Yellow Backlight (Fever)

>101.1°F or >38.4°C : Red Backlight (High Fever)

Notes: 1. Surface mode always displays the temperature with a Green backlight. 2. In body mode, 93.2-96.1°F (34.0- 35.6°C) will be displayed with a No LED backlight.”

Auto Power Off Time≤18 seconds
Measuring Time≤2 seconds

 

Measuring Distance0.4 inches to 2 inches (1 cm to 5 cm)
Memory50
Power Supply Requirements
Batteries1.5V (AAA) Alkaline battery x 2 (IEC Type LR03)
Operable Voltage Range2.6V~3.6V
Environmental
Operating EnvironmentTemperature: 59°F – 95°F (15°C – 35°C), Relative Humidity≤93% non-condensing, Atmospheric Pressure:

0.7 atm to 1.04 atm (70 kPa to 106 kPa)

Transport and Storage EnvironmentTemperature: -4 °F – 131°F (-20°C – -55°C), Relative Humidity ≤93%, non-condensing Atmospheric Pressure:

0.7 atm – 1.04 atm (70 Kpa – 106 Kpa)

Dimensions and Weight
Weight (without batteries)3.2 ounces (90g)

Size

L: 5.4” x W: 3.7” x H: 1.6” (L:138mm X W:95mm X H:40mm)
This infrared thermometer meets the requirements established in ASTM Standard E 1965-98 (for the thermometer system). Full responsibility for the conformance of the product to the standard is assumed by Kaz USA, Inc., a Helen of Troy Company, Health & Home, 400 Donald Lynch Blvd., Suite 300, Marlborough, MA 01752

ASTM laboratory accuracy requirements for the thermometer only in the display range of 36 °C to 39°C (96.8

°F to 102.2 °F) for infrared thermometers is ±0.3 °C (±0.5 °F), whereas for mercury-in-glass and electronic thermometers, the requirement per ASTM Standards E 667-86 and E 1112-86 is ±0.1 °C (±0.2 °F).

This device conforms to the following standards:

IEC 60601-1: Medical electrical equipment. Part 1: General requirements for basic safety and essential performance

ASTM E1965-98: Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature

ISO 80601-2-56: Medical electrical equipment – Requirements for basic safety and essential performance of clinical thermometers for body temperature measurement

IEC 60601-1-2: Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance – Collateral Standard: Electromagnetic disturbances – Requirement and tests

NOTE: DO NOT use this device in the presence of electromagnetic or other interference outside the normal range specified in IEC 60601-1-2.

IEC 60601-1-11: Medical electrical equipment – Part 1-11: General requirements for basic safety and essential performance – Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment

ISO 15223-1: Medical devices – Symbols to be used with medical device labels, labeling and information to be supplied – Part 1: General requirements”

 

Safety Classification of ME EQUIPMENT
Protection against electric shockInternally powered ME equipment
Applied partType BF Applied Part
Protection against harmful ingress of water or particulate matterIP22
Mode of operationContinuous operation

 

Note:
Not intended to be sterilized. Not for use in an OXYGEN RICH ENVIRONMENT Figure 2-Measuring position and distance MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC. For a detailed description of EMC requirements please contact Consumer Relations. Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT. Remove the battery from the instrument if it is not required for extended periods of time in order to avoid damage to the thermometer resulting from a leaking battery.

Operation

Battery installation
CAUTION:
The Non-Contact Infrared Body Thermometer does not operate with dead batteries and does not input outer power. Install new batteries.

  1. Pull the battery door out in the direction of the arrow and then lift up to access the battery compartment.
  2. Insert two AAA-size batteries according to the “+” and “-”.
  3. Close the battery cover.
How to Operate Before Applying the Thermometer

Be sure to read and understand all warnings listed in the instructions before use.

  • The thermometer should align with the middle of the forehead to measure body temperature (between and directly above the eyebrows) at a vertical distance. Press the On (Trigger) button and the temperature will display immediately, see Figure 2
    Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 14
  • Before using, allow the thermometer to remain in the room in which it will be used for 30 minutes. The room temperature should be between 59°F and 95°F (15°C and 35°C).
  • The ambient temperature around the test person should be stable. DO NOT take human temperature measurements near air flow from fans, air-conditioning vents, etc.
  • Wait at least 1 second for the next measurement. If measuring continuously five times, it is recommended to wait at least 30 seconds and then continue the measurement.

General Setup and Use

Start measuring
Align the device to forehead at a distance of 1-5cm (0.4-2.0 inches), then press the On (Trigger) button to start the measurement and read the data. The thermometer will perform a self-test with all segments displayed for 2 seconds.

Note:
After the full display is over, you will hear a single “beep” for a normal temperature or 4 “double beeps” for an elevated temperature, which means that the measurements have been completed. The target value of the measured temperature is displayed on the LCD, while the backlit displays one of three colors red, green, and yellow.

Green means ready for the next measurement. If 99.3°F – 101.1°F (37.4°C-38.4°C), yellow is displayed, which means a slight fever warning. Please pay attention to body temperature. When the body temperature is above 101.1°F, red is displayed, which means high fever. Please take action to cool down or go to a doctor. 2) To ensure the accuracy of the measurement, wait at least 30 seconds after 5 consecutive measurements.

Mode conversion
When the device is on, press the MODE button to cycle conversion between “body” mode and “surface” mode. “body” mode is used for measuring human body temperature, and the “surface “ mode is used to measure the surface temperature. (The factory default is “body” mode).

Advanced Settings:

Fever Alert Set – F2
This setting will change at what point the backlight color of the temperature reading turns to red. After entering the screen for changing the temperature scale, F1, press the “SET” button to enter F2. Press the “MODE” button to decrease this value by 0.1°C The factory default and highly recommended temperature to have this set at is 38.5°C (101.2°F)

Sound Settings – F3
This setting will change the buzzer to be on or off. While in Fever Alert Setting, F2, press the “SET” button to enter F3. Press the “MODE” or the “MEMO” button to turn the volume on or off. Press the “SET” button to save this setting. This can also be changed using the directions outlined in “Turning the Sound On/Off”.

Troubleshooting

MESSAGESITUATIONSOLUTION
 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 15

 

 

The temperature taken is not within the Typical human temperature range. (93.2°F~109.2°F or 34.0°C~42.9°C).Make sure the forehead thermometer is for forehead measurement, not another human body site.
 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 16°

 

 

 

 

 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 18

 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 17

 

 

Body °F

Measured over the distance: 0.4-2in (1-5 cm)Optimum measurement distance is .4in (1cm)
Incorrect test position.See figure 2 measuring position and distance.
Subjects’ forehead hair, Antipyretic stickers, head with sweat, etc.Have subjects sit quietly 5-10 minutes before the test.
 

 

Body °F

 

 

 

Operating temperature exceeds the range of specified temperature.Move to a room within the operating range and wait 30 minutes before taking temperature.
Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 19The screen flicker automatically turns off.Replace the battery or the product has been damaged, and needs repairs
Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 20

 

Low Battery Warning: When the battery is running low, the display flashes the low battery warning symbol; however, the device can still work until the battery life

has 0% left

Install a new battery. See “Replacing the Battery” for instructions.
Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 21Dead Battery Warning: The device cannot take the temperature.Install a new battery. See “Replacing the Battery” for instructions.
 

Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 22

Ambient temperature changes too fast.Wait until the ambient temperature is stable.
Vicks VNT275USV1 Non Contact Infrared Thermometer Guide fig 23(1) Power is off.

(2) Improper battery installation.

 

(3) Display remains blank.

(1) Press ON button again.

(2) Check the battery polarity.

(3) Replace with a new battery.

(4) Contact the retailer or service center.

Replacing the Battery
  1. Open and release the battery cover following the indicator on the surface of the battery cover.
  2. Remove the battery and replace it with 2 new ones, type AAA. Make sure to align properly as indicated inside the battery cover.
  3. Slide the battery cover back in until it snaps in place. Do not dispose of used batteries in household waste. Take them to special local collection sites.
  4. Just take off the batteries, wait 30 sec, then load the batteries again.

Cleaning, Care, and Storage

  • The lens is very delicate.
  • It is very important to protect the lens from dirt and damage.
  • Use a clean, soft cloth to clean the surface of the device and LCD. Do not use solvents or immerse the device in water or other liquids.
  • Always keep the thermometer within the storage temperature range (-4°F to 131°F or -20°C to 55°C) –and humidity range (≤93% non-condensing).
  • When the ambient temperature of the thermometer changes too much, such as moving the thermometer from one place of lower temperature to another place of higher temperature, allow the thermometer to remain in a room for 30 minutes where the temperature is between 59°F- 95°F (15°C to 35°C)

Warranty

  • A. This 1-year limited warranty applies to the repair or replacement of a product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use, or supplemental damage.
    Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
  • B. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual. Call us toll-free at 1-800-477-0457 or e-mail: ConsumerRelations@HelenofTroy.com.