Insignia 8000 BTU Window Air Conditioner User Guide
Introduction
Congratulations on your purchase of a high-quality Insignia product. Your NS-AC8WU3 represents the state of the art in air conditioner design and is designed for reliable and trouble-free performance.
IMPORTANT SAFEGUARDS
Read this manual carefully before installing or operating your new air conditioning unit. Make sure that you save this manual for future reference. To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
WARNING
- Plug in power plug properly. Otherwise, it may cause electric shock or fire due to excess heat generation.
- Always use a circuit breaker and a dedicated power circuit. Incorrect installation may cause fire and electric shock.
- Always ensure effective grounding. Incorrect grounding may cause electric shock.
- Unplug the unit if strange sounds, smell, or smoke comes from it. It may cause fire and electric shock.
- Keep firearms away. It may cause fire.
- Ventilate the room before operating your air conditioner if there is a gas leakage from another appliance. It may cause explosion, fire, and burns.
- Do not operate or stop the unit by inserting or pulling out the power plug. It may cause electric shock or fire due to heat generation.
- Do not operate with wet hands or in damp environment. It may cause electric shock.
- Do not allow water to run into electric parts. It may cause failure of machine or electric shock.
- Do not use the socket if it is loose or damaged. It may cause fire and electric shock.
- Do not use the power cord close to heating appliances. It may cause fire and electric shock.
- Do not damage or use an unspecified power cord. It may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard.
- Do not direct airflow at room occupants only. This could damage your health.
- Do not modify power cord length or share the outlet with other appliances. It may cause electric shock or fire due to heat generation.
- Do not open the unit during operation. It may cause electric shock.
- Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.
- Do not disassemble or modify unit. It may cause failure and electric shock.
CAUTION
- When your air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury.
- Do not use strong detergent such as wax or thinner but use a soft cloth. Appearance may be deteriorated due to change of product color or scratching of its surface.
- Stop operation and close the window in storm or hurricane. Operation with windows opened may cause wetting of indoor and soaking of household furniture.
- Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure.
- Do not place obstacles around air-inlets or inside of air-outlet. It may cause failure of appliance or accident.
- Use caution when unpacking and installing. Sharp edges could cause injury.
- Do not put a pet or house plant where it will be exposed to direct air flow. This could injure the pet or plant.
- Do not clean your air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock.
- When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire and electric shock. It may cause an injury.
- Hold the plug by the head of the power plug when taking it out. It may cause electric shock and damage.
- Do not place heavy object on the power cord and ensure that the cord is not compressed. There is danger of fire o electric shock.
- Ventilate the room well when used together with a stove, etc. An oxygen shortage may occur.
- Do not use for special purposes. Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
- Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure. If bracket is damaged, there is concern of damage due to falling of unit.
- Turn off the main power switch when not using the unit for a long time. It may cause failure of product or fire.
- Do not drink water drained from air conditioner. It contains contaminants and could make you sick.
- If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate from the electrical supply by taking the power-plug out and contact a qualified service technician.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mentalcapabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning
- use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons
- in order to avoid a hazard.
- The appliance shall be installed in accordance with national wiring regulations.
- Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
- Contact an authorized service technician for repair or maintenance of this unit
- Contact an authorized installer for installation of this unit.
IMPORTANT SAFETY INSTRUCTIONS
- NOTE: The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to Operation of Current Device on page 6 for details. In the event that the power supply cord is damaged, it cannot be repaired. It must be replaced with a cord from the product manufacturer.
- WARNING: Avoid fire hazard or electric shock. Do not use an extension cord or an adapter plug. Do not remove any prong from the power cord.
- WARNING: For your safety, do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- Do not use this device to turn the unit on or off.
- Always make sure the RESET button is pushed in for correct operation.
- The power supply must be replaced if it fails reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer. If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the product manufacturer.
- This air conditioner is designed to be operated under conditions as follows:
- Explanation of the symbols displayed on the unit (uses R290/R32 refrigerant only).
- WARNING: (for using R290/R32 refrigerant only)
- Do not use heat as a means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance) and ignition sources or (for example, an operating electric heater) close to the appliance. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that the refrigerants may not contain an odor.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- DO NOT modify the length of the power cord or use an extension cord to power the unit. DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
- Please follow the instruction carefully to handle, install, clear, and service your air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing of the air conditioner, the refrigerant (R32 or R290) shall be recovered properly and shall not discharge to air directly.
- No open fire or device-like switch which may generate spark/arcing shall be around your air conditioner to avoid causing ignition of the flammable refrigerant used. Please follow the instruction carefully to store or maintain your air conditioner to prevent mechanical damage from occurring.
- Flammable refrigerant R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.
Prevent accidents
WARNING: To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
- Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.
- If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple track type with a screen panel included, remove the screen completely before installation.
- Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
- When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
Electrical information
WARNING: The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.
- Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
- Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation.
- Do not run air conditioner without side protective cover in place. This could result in mechanical damage within the air conditioner.
- Do not use an extension cord or an adapter plug.
Operation of Current Device
Applicable to the units with current detection device only) The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
- Plug in the air conditioner.
- The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
- Press the RESET button. Again you will notice a click as the button engages.
- The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.)
WARNINGS (for using R290/R32 refrigerant only)
- Transport of equipment containing flammable refrigerants See transport regulations
- Marking of equipment using signs See local regulations
- Disposal of equipment using flammable refrigerants See national regulations.
- Storage of equipment/appliances The storage of equipment should be in accordance with the manufacturer’s instructions.
- Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
- Information on servicing
- Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
- Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.
- General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
- Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed, or intrinsically safe.
- Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
- No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing, and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
- Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
- Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:
- The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
- The ventilation machinery and outlets are operating adequately and are not obstructed; If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
- Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
- Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include:
- That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
- That no live electrical components and wiring are exposed while charging, recovering or purging the system;
- That there is continuity of earth bonding.
- Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected.
- This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
- Ensure that apparatus is mounted securely.
- Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
- NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
- Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
- Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
- Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. - halide torch (or any other detector using a naked flame) shall not be used.
- Leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at apercentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
- Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose, conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. Opening of the refrigeration systems shall not be done by brazing. The following procedure shall be adhered to:
- Remove refrigerant;
- Purge the circuit with inert gas;
- Evacuate;
- Purge again with inert gas;
- Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
- Charging procedures In addition to conventional charging procedures, the following requirements shall be followed.
- Ensure that contamination of different refrigerants does not occur when using charging equipment.
- Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- Label the system when charging is complete (if not already).
- Extreme care shall be taken not to overfill the refrigeration system.
- Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
- Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
- Become familiar with the equipment and its operation.
- Isolate system electrically.
- Before attempting the procedure ensure that:
- Mechanical handling equipment is available, if required, for handling refrigerant cylinders;
- All personal protective equipment is available and being used correctly;
- The recovery process is supervised at all times by a competent person;
- Recovery equipment and cylinders conform to the appropriate standards.
- Pump down refrigerant system, if possible.
- If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- Make sure that cylinder is situated on the scales before recovery takes place.
- Start the recovery machine and operate in accordance with manufacturer’s instructions.
- Do not overfill cylinders. (No more than 80% volume liquid charge).
- Do not exceed the maximum working pressure of the cylinder, even temporarily.
- When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
- Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
- Labeling Equipment shall be labeled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
- Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
Features
- 8,000 BTU is ideal for rooms up to 350 sq. ft. (32.5 sq. m) of living space
- Three unique fan speeds and a temperature range of 60° F-86° F(16° C-30° C) keep you cool and comfortable
- Specially designed to fit vertical sliding windows
- Digital controls make it quick and easy to adjust your settings
- Oscillating fan lets you manually adjust side-to-side motion
- Included remote control works from up to 26.2 ft. (8 m) away
- Auto restart function restores your previous settings, in the event of a power outage
- 4.9 ft. (1.5 m) power cord easily reaches nearby outlets
- Simple white color looks modern and matches any décor
Package contents
- Window air conditioner
- Mounting hardware
- Remote control
- AAA batteries (2)
- User Guide
Tools required
Installation hardware
Note: Save the carton and these instructions for future reference. The carton is the best way to store your air conditioner during the winter or when not in use.
Air conditioner
Air conditioner support bracket
Control panel
Remote control
Remote control display screen
Using the remote control
Notes:
- The remote control must be pointed at your air conditioner and used within 26.2 ft. (8 m).
- Your air conditioner will beep when the remote control signal is received.
- Curtains, other materials, and direct sunlight can interfere with the infrared signal receiver.
Installing the remote control batteries
Notes:
- Do not mix old and new batteries, or batteries of different types.
- Do not leave batteries in the remote control if you don’t plan on using the device for more than two months.
- Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal.
- Slide the cover of the battery compartment off.
- Insert two AAA (included) batteries. Make sure that the + and – symbols on the batteries match the symbols in the battery compartment.
- Reinstall the cover.
Before you mount your air conditioner
Understanding the window requirements
Your air conditioner is designed to install in standard double hung windows with opening widths of 22-36 in. (55.9-91.4 cm) and a window height of 13.5 in. (34.3 cm). The lower sash must open sufficiently to allow a clear vertical opening of 13.7 in. (34.9 cm). Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser for heat removal. The rear of the unit must be outdoors, not inside a building or garage.
Vinyl-clad windows
Dealing with storm windows
If a storm window blocks your air conditioner, remove it before installing your air conditioner. If the storm window cannot be removed:
- Make sure that the storm window’s drain holes or slots are not caulked or painted shut. Accumulated rain water or condensation must be able to drain out.
- Attach a piece of wood across the entire window sill with nails or screws to correctly angle your air conditioner. Your air conditioner should be tilted back about 3-4° downward toward the outside. After proper installation, condensate should not drain from the overflow drain hole during normal use. If it does, adjust the angle of your air conditioner.
- You must secure the support bracket to the added wood piece using the provided 1” type A screws. Refer to Step 2: Installing the support bracket on page 18.
Installing your air conditioner
Step 1: Preparing the support bracket
- Remove your air conditioner, support bracket, and hardware from the box and place on a flat surface.
- Remove the packing material.
- Find the center of your window and lightly mark it with a pencil.
- Press the left spring push pin and adjust the left extension arm out, then do the same for the right extension arm.
- Measure the width of the inner windowsill. Making sure that the center of the support bracket lines up with the center of the window, then adjust the extension arms to the width you just measured. The support bracket will be offset to the left when centered.
- Cut bracket sealing foam strips to length and apply to the bottom of the bracket.
Step 2: Installing the support bracket
CAUTION: Maintain control of the bracket until the installation is complete.
- Open the window where your air conditioner is being installed.
- Place the main support bracket into the window opening, making sure that the horizontal bracket and extension arms are located on the indoor side of the window.
- Lower the bracket until it rests on the windowsill.
- For wooden windows with a flat sill, secure the bracket to the windowsill by drilling 1/8 in. pilot holes and securing the bracket to the window with the 1/2” and 1” type A screws.
Note: If the gap between the bracket and the window sill exceeds 3/16 in. (5 mm), the bracket may be deformed while securing the 1″ type A screws, you can add a block to reduce the gap if possible.
OR
- For vinyl windows with a flat sill, secure the bracket to the windowsill by drilling 1/8 in. pilot holes and securing the
bracket to the window with the 1/2” type A screws.
- Move the angled support arms toward the exterior wall until the feet touch the wall. Place a level on the bracket and adjust the support arms so that it is level or tilted 1/4 bubble downward and towards the outside.
- Insert the main support pin through the holes in the main support and angled support arm.
- Using the numbers on the main support, repeat the adjustment for the other angled support arm matching the hole number from the first support arm.
- Check the level again and make sure that the bracket is secure. If further adjustment is required, use alternate holes where the main supports attach to the horizontal bracket.
- After making any final adjustments, insert the two cotter pins into the main support pin on both support brackets.
- If necessary, cover the holes on the front of the bracket with bracket sealing foam.
Step 3: Installing your air conditioner on the support bracket
CAUTION: Do not leave your air conditioner unattended during installation.
- Measure the width of your window track (the vertical track your window slides up and down in). If it measures 1/2“ or less, flip the anti-tip bracket so that the small end faces out, then continue with your air conditioner installation.
- Set your air conditioner on top of the support bracket, making sure that the grooves on the bottom of your air conditioner align with the main supports. Using a level, check for proper tilt towards the outside.
- Pull the window down into the slot on top of your air conditioner to help align it correctly. Keep the window partially inserted into the slot to help support your air conditioner during installation.
- Fold down both side arm hinges.
- Using 1/4 in. and 1/2 in. type B screws, install the open window brackets with an “L” shaped screwdriver, if needed.
WARNING: Failure to install the open window brackets could cause injury or property damage.
Step 4: Installing the sealing foam and anti-tip brackets
CAUTION: Do not leave your air conditioner unattended during installation.
- Measure the distance between the right side arm hinge and the closest part of the window frame. Add 1/4 in. to this distance and cut the side arm foam block to width.
- Apply window sealing foam to the side arm foam block as shown. Note that the window sealing foam attaches to the side next to your air conditioner.
- Insert a side arm foam block into the side arm hinge until the top front of the side arm foam is flush with the top of the hinge.
- Repeat steps 1 through 3 for the left side of your air conditioner.
- Remove the two 1/2 in. screws from the top left and right sides of your air conditioner.
CAUTION: The factory installed 1/2 in. screws must be re-used to secure the anti-tip brackets. Failure to use these screws could result in damage to your air conditioner.
- Extend the anti-tip brackets (one on each side of your air conditioner) into the window tracks (the vertical track in which your window slides up and down) until they stop.
- Secure the brackets in place using the screws you removed.
- Install a strip of window sealing foam to the bottom of your lower window sash, sealing any small gaps between the window and your air conditioner, then close the window and check for gaps.
- Fill any gaps with the included foam, as needed.
- Extend the integrated window locks (located in the U channel) until they contact the window. For additional security, you can install the optional sash lock.
- To secure the lower sash in place, attach the right angle sash lock with 1/2 in. type A screws.
- Cut strips of window sash foam and insert them in the space between the upper and lower sashes.
- As a final check, review the installation and check for any gaps or openings. Seal any gaps with additional sealing foam (provided), to make sure that there are no leaks.
Using your air conditioner
Notes:
- If your air conditioner turns off unexpectedly due to a power outage, it will automatically restart with the previous settings when the power resumes.
- The cooling circuit has an automatic three minute delay if your air conditioner is turned off and on quickly. This prevents overheating of the compressor and possibly tripping the circuit breaker. The fan continues to run during this time.
- The relative humidity of the room should be less than 80%. If the unit is used in a condition with a relative humidity over 80%, water will condense on the surface of your air conditioner.
- For optimum performance, outdoor temperatures should be from 64° F to 109° F (18° C to 43° C), and indoor temperatures should be from 60° F to 90° F (16° C to 32° C).
You can control your air conditioner by using the control panel on the front of the unit or by using the remote control. If using the remote control, always point it at the control panel on your air conditioner.
Using your air conditioner for the first time
- Plug in your air conditioner (be sure to follow the power cord instructions on page 4).
- Turn the power on to your air conditioner using the ON/OFF button.
- Select the Cool mode setting.
- Adjust the louvers for comfortable air flow (see Controlling air flow on page 29).
- Make sure that the air flow, both inside and outside, is not obstructed.
- Once the room has cooled, adjust the thermostat to a comfortable setting.
Turning your air conditioner on/off
Plug in your air conditioner, then press on your air conditioner, or ON/OFF on your remote control, to turn your air conditioner on or off.
Selecting an air conditioner mode
Press the MODE button repeatedly, on your air conditioner or your remote control, to cycle through Auto, Cool, Dry, and Fan modes. An indicator lights to show which mode is selected.
- Auto: Your air conditioner automatically selects cooling or fan, depending on the temperature you have selected and the room temperature. Fan speed cannot be adjusted, and it starts or stops based on the room temperature. You can adjust the temperature setting up to 86° F (30° C) or down to 60° F (16° C). The display shows the set temperature.
- Cool: Your air conditioner cools your room, with the compressor turning on and off and the fan remaining on to maintain the temperature you have selected. You can adjust the temperature setting up to 86° F (30° C) or down to 60° F (16° C). The display shows the set temperature.
- Dry: Your air conditioner operates as a dehumidifier. Some degree of cooling may occur as well.
- Fan: Your air conditioner circulates or exhausts air but does not cool the room. The display shows the actual room temperature, not our set temperature.
Selecting the fan speed
Press the FAN button repeatedly to cycle through the available fan speeds. Choices include Auto, Low, Med, or High. In Dry mode, the fan speed is set to Low automatically.
Using ECO (energy saver) mode
While using the ECO mode, the fan runs for three minutes after the compressor shuts off, then cycles on for two minutes at 10-minute intervals. When the room temperature is above the set temperature, the compressor turns back on and starts cooling again.
- Press the ECO button on your air conditioner to turn on ECO mode when using Cool, Dry, or Auto (auto-cooling or auto-fan) modes.
Note: Your air conditioner automatically initiates ECO mode in the Cool, Dry, and Auto (auto-cooling or auto-fan) modes.
Setting the timer
The combined on/off timer lets you automatically start and stop your air conditioner after a set amount of time. You can set Timer On to Off or Timer Off to On using your air conditioner control panel or the remote control.
Timer On
Set the timer to automatically turn on your air conditioner after a set time.
- Press the TIMER button on your air conditioner, or TIMER ON on the remote control, until the Timer On LED or (on the remote control) lights.
- To set how long to wait before your air conditioner turns on, press (up/down arrows) to adjust the delay time from 0.5–10 hours in half-hour increments, then 10–24 hours in one-hour increments. Your air conditioner starts running after the timer counts down from the set time.
- Using the control panel, the setting is automatically saved after five seconds. OR
- Point the remote control at your air conditioner unit and the setting is saved after one second.
Note: To cancel the timer program, set the timer to 0:0 hours on the control panel. Your air conditioner turns off.
Timer Off
Set the timer to automatically turn off your air conditioner after a set time.
- Press the TIMER button on your air conditioner, or TIMER OFF on the remote control, until the Timer Off LED or (on the remote control) lights.
- To set how long you want your air conditioner to run, press (up/down) to adjust the delay time from 0.5–10 hours in half-hour increments, then 10–24 hours in one-hour increments. Your air conditioner stops running after the timer counts down from the set time.
- Using the control panel, the setting is automatically saved after five seconds. OR
- Point the remote control at your air conditioner unit and the setting is saved after one second.
Note: To cancel the timer program, set the timer to 0:0 hours on the control panel. Your air conditioner turns on.]
Timer On to Off
Set Timer On to Off to automatically turn your air conditioner on, then back off, after a set time.
- Press TIMER ON until the Timer Off LED lights.
- To set how long to wait before your air conditioner turns on, press (up/down) to adjust the delay time from 0.5– 10 hours in half-hour increments, then 10–24 hours in one-hour increments.
- Press TIMER ON again. The number next to Timer Off blinks.
- To set how long you want your air conditioner to run, press (up/down) to adjust the delay time from 0.5–10 hours in half-hour increments, then 10–24 hours in one-hour increments. The setting is automatically saved after pointing the remote control at your air conditioner for one second. Your air conditioner starts when the Timer On time elapses, then turns off again after the Timer Off time elapses.
Note: To cancel the timer program, set the timer to 0.0 h.
Timer Off to On
Set Timer Off to On to automatically turn your air conditioner off, then back on, after a set time.
- Press TIMER OFF until the number next to Timer Off blinks.
- To set how long you want your air conditioner to run, press (up/down) to adjust the delay time from 0.5–10 hours in half-hour increments, then 10–24 hours in one-hour increments.
- Press TIMER OFF again. The number next to Timer On blinks.
- To set how long to wait before your air conditioner turns on, press (up/down) to adjust the delay time from 0.5– 10 hours in half-hour increments, then 10–24 hours in one-hour increments. The setting is automatically saved after pointing the remote control at your air conditioner for one second. Your air conditioner turns off when the Timer Off time elapses, then turns on again after the Timer On time elapses.
Note: To cancel the timer program, set the timer to 0.0 h.
Using the remote as a thermostat (I SENSE)
The remote control can function as a remote thermostat for precise temperature control at its location.
- To turn on the I SENSE feature, aim the remote control toward your air conditioner and press I SENSE. The remote
displays the temperature at its actual location and sends a signal to your air conditioner every three minutes.
Note: I SENSE can only be turned on with the remote control.
- To turn off I SENSE, press I SENSE again.
Note: Make sure that the remote control is turned toward the air conditioner when I SENSE is on, and there should be no obstacle between the remote control and the air conditioner. If your air conditioner does not receive the I SENSE signal during any 7-minute interval, your air conditioner beeps to indicate that I SENSE mode has ended.
Using the check filter reminder
- The check filter indicator lights (the LED above the SWING button on your air conditioner) automatically after 250 hours of operation. See Cleaning the air filter on page 30.
- To reset after cleaning the filter, press and hold the SWING button for three seconds. The light turns off.
Using sleep mode
During Sleep mode, the temperature will increase by 2° F (1–2° C) 30 minutes after the mode is selected, then increase by another 2° F (1–2° C) after an additional 30 minutes. This new temperature is maintained for 6–7 hours, then Sleep mode turns off. Your air conditioner cools to the original temperature and continues to operate as first programmed.
- Press the SLEEP button to turn on sleep mode. The sleep indicator on your air conditioner, or on the remote control lights.
- To turn off Sleep mode, press the SLEEP button again. The sleep indicator on your air conditioner, or on the remote control turns off.
Turning the display on or off
Press the LED button on your air conditioner, or the LED DISPLAY button on your remote control, to turn your air conditioner display on or off.
Locking air conditioner settings
- Press I SENSE and TIMER OFF for five seconds to lock the remote control’s settings so that they cannot be changed.
Press I SENSE and TIMER OFF for two seconds again to unlock the remote control.
Controlling air flow
The louvers on the front of your air conditioner let you direct the air flow up or down and left or right throughout the room as needed. Press the SWING button until the desired up/down direction is obtained. Move the louvers from side to side until the desired left/right direction is obtained.
Note: The up/down louvers cannot be adjusted manually.
Understanding sounds
These sounds are part of your air conditioner’s normal operation.
Cleaning and maintaining your air conditioner
CAUTION: Unplug your air conditioner before cleaning to prevent shock or fire hazards.
Cleaning the cabinet
- Dust the cabinet and front with an oil-free cloth, or wash with a cloth dampened in a solution of warm water and mild liquid dish-washing detergent. Rinse thoroughly and wipe dry.
- Never use harsh cleaners, wax, or polish on the cabinet.
- Make sure that you wring excess water from the cloth before wiping around the controls. Excess water in or around the controls can damage your air conditioner.
Cleaning the air filter
Note: Never use hot water over 104° F (40° C) to clean the air filter. Never attempt to use your air conditioner without the air filter.
- Open the front panel of your air conditioner.
- Grasp the center of the filter, then pull up and out.
- Wash the filter with warm water, then rinse thoroughly. Gently shake excess water from the filter, and let it air dry. Make sure that the filter is thoroughly dry before replacing it. OR Vacuum the filter to remove dust and other debris.
Storing your air conditioner
If you plan to store your air conditioner during the winter, remove it carefully from the window (see Removing your air conditioner from the window on page 30) and cover it with plastic or return it to its original box.
Removing your air conditioner from the window
- Turn your air conditioner off, and disconnect the power cord.
- Remove the sash sealing foam from between the windows, then unscrew the safety sash lock.
- Retract the integrated window locks, if used.
- Remove the screws and retract the anti-tip brackets.
- Remove the side arm foam blocks from both sides of your air conditioner.
- Keeping a firm grip on your air conditioner, raise the window sash and carefully remove your air conditioner.
Note: Be careful not to spill any remaining water while lifting your air conditioner from the window. Store parts with your air conditioner.
Troubleshooting
Specifications
Legal notices
FCC and IC Information:
The device should comply with the local national regulations.
- In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
- In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment complies with Industry Canada radiation exposure limits set forth for an uncontrolled environment.
California Residents
WARNING: Cancer and reproductive harm – www.p65warnings.ca.gov
ONE-YEAR LIMITED WARRANTY
The Distributor* of Insignia branded products warrants to you, the original purchaser of this new Insignia-branded product (“Product”), that the Product shall be free of defects in the original manufacturer of the material or workmanship for a period of one (1) year from the date of your purchase of the Product (“Warranty Period”). For this warranty to apply, your Product must be purchased in the United States or Canada from a Best Buy branded retail store or online at www.bestbuy.com or www.bestbuy.ca and is packaged with this warranty statement.
Contact Insignia:
1-877-467-4289 www.insigniaproducts.com INSIGNIA is a trademark of Best Buy and its affiliated companies. *Distributed by Best Buy Purchasing, LLC 7601 Penn Ave South, Richfield, MN 55423 U.S.A ©2022 Best Buy. All rights reserved
DOWNLOAD PDF LINK