Airthereal APH260 Pure Morning HEPA Air Purifier User Manual
COMPONENTS
SPECIFICATIONS
OZONE DENSITY about HEPA AIR PURIFIER
This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on an averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m³.
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT:
Please read and comply with all of the instructions and warnings in the manual before using. Failure to comply with the instructions and warnings provided herein may result in inaccurate results and/or damage to the product itself.
General Safety Only use this air purifier as described in this manual.
- Ensure the plug fits properly into an AC power outlet.
- When not being used, turn the air purifier off and disconnect it from its power source by unplugging from the electrical outlet.
- DO NOT operate the unit if its cord or plug is damaged. It may result in damage to the unit or injury. It must be replaced by the manufacturer or other qualified person so as to avoid all risks.
- NOT recommend using an extension cord. If necessary, the extension cord should be same size as the original one.
- Thoroughly dry your hands before operation.
- DO NOT immerse air purifier in water or liquids. It may result in damage to the appliance, electric shock, or fire.
- DO NOT use the air purifier outdoors. This appliance is designed for indoor use only.
- DO NOT use the air purifier in an enclosed space where flammable, combustible, or explosive gases are present.
- DO NOT use in an area where toxic vapors, flammable dust or oxygen tanks are present.
- DO NOT insert fingers or objects into the air outlet.
- Child supervision is required while the air purifier is on. Do not allow children to play on or near the air purifier.
Use & Care
- Always make sure to place the air purifier on a flat, level surface before operation.
- Always allow 15 inches (38 cm) of clearance on all sides of the purifier.
- DO NOT ROUTE CORD UNDER FURNITURE OR APPLIANCES. Do not run the power cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Place the power cord away from high traffic areas.
- DO NOT sit on or place anything on top of the purifier.
- DO NOT place the air purifier near sources of heat, such as stoves, ovens, radiators or computers.
- DO NOT use this appliance with indoor smoke-type insect repellents or in places with oily residues, burning incense or chemical fumes.
- DO NOT open the back shell while the air purifier is on. It will automatically turn off the unit.
- Always unplug the appliance from the power supply before servicing.
- DO NOT clean the appliance with water or any other liquid to avoid electric shock or injury.
- DO NOT attempt to repair this device in any way or use any replacement components or parts to modify the air purifier. Contact Customer Support immediately if your appliance is no longer working.
- Only use Airthereal Pure Morning APH260 replacement filters for this unit.
- If you experience any problems while operating the air purifier, refer to the Troubleshooting section in the manual. If the problem is NOT solved, contact Customer Support.
- If the unit is damaged or NOT functioning properly, discontinue use and contact Customer Support.
INSTALLATION INSTRUCTIONS
- Open the front shell of the air purifier and unwrap the plastic package of the HEPA filter.
- Reinstall the HEPA filter. Make sure the pull-tab is facing outward. Then install the front shell.
NOTE: If the front shell is not installed properly, it will remain power off.
- Place the air purifier where desired. Place at least 15 inches away from TVs, radios, and other electronic products. Electromagnetic interference from certain electronics may cause product malfunction. Only use the unit on the firm and flat surfaces. Flimsy or slanted surfaces may result in abnormal noise and vibrations.
OPERATION
- Insert the power cord into an electrical outlet.
WARNING
Follow these instructions to reduce the risk of serious injury or death and to reduce risk of damaging the unit.
Follow these instructions to reduce the risk of serious injury or death and to reduce risk of damaging the unit. Please make sure the operating voltage is the same as parametric label. For American and Canadian users, our product will equipped with a POLARIZED AC PLUG that will fit into the power outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet.
- Touch-control panel Introduction
Power Button
Power on/off. Press the button to process power. The blue breath light of the air quality indicator will twinkle for 30 seconds. Meanwhile, it starts to detect the PM2.5 value on the LED display.
Fan Speed
Press to start air circulation. 3 fan speeds are available (low, medium, and high, corresponding with the values 1, 2, and 3 on the LED Display).
Anion
Press to activate/inactivate the Anion Mode. When the anion function is on, it becomes an air ionizer that uses high voltage to ionize air molecules. Anions are particles with one or more extra electron, conferring a net negative charge to the particle. It’s used to eliminate the occurrence of air-borne bacterial infections and to reduce static electricity buildup in electronics.
Timer
Press to switch to timing mode. (Timing can be set from 1-12 hours or to NO TIMER, corresponding to values 1-12 and 00 on the LED display.)
Sleep Mode
Press to turn on / off the Sleep Mode.
NOTE:
- Sleep Mode is the lowest fan speed.
- When Sleep Mode is activated, the Air Quality Indicator is disabled.
- Tap ‘FAN ’ or ‘AUTO ’ to exit Sleep Mode.
Auto Mode
- Press to activate auto mode. It will operate depending on the current air quality index.
- Real-time PM2.5 value will also illuminate on the LED display.
- The air quality indicator light at the top will also brighten with its respective color.
- Tap ‘FAN ’ or ‘SLEEP MODE ’ to exit Auto Mode.
Instant PM2.5 value is one of the core references for indoor air quality index (AQI). Regarding the AQI, working modes, and lights indicators, Airthereal APH260 Air Purifiers comply with EPA regulations. For additional Information, please reference the United States Environmental Protection Agency (EPA): https://cfpub.epa.gov/airnow/index.cfm?action=aqi_brochure.index#particle
UV-C Light
Press to activate/inactivate the UV-C Light mode. UV-C refers to ultraviolet light with wavelengths between 200 – 280 nanometers (nm). It can be used for destroying harmful micro-organisms in food products and in the air. Airthereal Pure Morning APH260 Air Purifier has passed the ETL stringent testing requirements. The UV-C light is rated at 50,000 hours, or slightly longer than 5 years. It’s no need to replace the UV light for normal maintenance.
MAINTENANCE
Know the 7-in-1 HEPA Filter
When the replacement icon lights up (PM2.5 light turn RED and keep flashing), it is a reminder to check and change the air filter.
- Recommend replacing the air filter every 6-8 months for optimal use. Or according to your air filter status.
- Time to replace the air filter when below signals appear:
- Increased noise
- Decreased airflow
- Clogged filters
- Presence of odors from the unit
Purchase a new Airthereal Air Filter Replacement:
www.airthereal.com
Search on Amazon: APH260 filter / B07G74NYG6
Only use Airthereal Pure Morning APH260 replacement filters for this unit.
Replace the Air Filter
- Power off and unplug before operating.
- Remove the front shell.
- Take out the old filter by pulling the tab. Unwrap a new one.
- Install a new filter in the unit. Make sure the pull-tab on the filter is facing outward and put the front shell on.
- Process power. Press and hold the button & simultaneously for 3 seconds to reset the replacement reminder.
Note: Automatic Power Off when the front shell not installed properly.
Cleaning
Unplug the power cord before cleaning.
- Plastic housing should be cleaned with a soft cloth moistened with mild soap. Thoroughly remove soap film with dry cloth.
- Open the front panel and clean the interior and air outlet with a vacuum cleaner.
- For better maintenance, clean the unit every 2 months.
TROUBLESHOOTING
WARRANTY
TERMS & POLICY
Quality has always been Airthereal’s top priority. For your 100% hassle-free shopping experience, Airthereal provides a 2-Year manufacturer´s limited warranty for APH260 Air Purifiers. Internet information: airthereal.com/pages/warranty
DOWNLOAD PDF LINK