IMPORTANT SAFETY INSTRUCTIONS

DANGER:
Failure to read the Owner’s Manual prior to operating or attempting any service or maintenance procedure to your machine could result in injury to you or to other personnel; damage to the machine or to other property could result as well. You must have training in the operation of this machine before using it. If you or your operator(s) cannot read English, have this manual explained fully before attempting to operate this machine. Operating a machine that is not completely or fully assembled could result in injury or property damage.

Do not operate this machine until it is completely assembled. Inspect the machine carefully before operation. Use only as described in this manual. Use only the manufacturer’s recommended attachments. Using a machine with a damaged power cord could result in an electrocution. Do not use the machine if the power cord is damaged. Do not use the electrical cord to move the machine. Keep the cord away from heated surfaces. Do not unplug by pulling on the cord; grasp the plug, not the cord. Turn off all controls before unplugging. Do not close a door on a cord or pull around sharp edges or corners.

Warning:

Operating a machine without observing all labels, decals, etc., could result in injury or damage. Read all machine labels before attempting to operate the machine. Make sure all of the labels are attached or fastened to the machine. Get replacement labels and decals from the manufacturer’s distributor. Electrical components can “short out” if exposed to water or moisture. Keep the electrical components of the machine dry. Always store the machine in a dry area

Use of this machine to move other objects or to climb on could result in injury to the operator or damage to the machine. Do not use this machine as a step or furniture. Do not allow it to be used as a toy. Close attention is necessary when used by or near children. Moving parts of this machine can cause injury and/or damage. Keep hands, feet, loose clothing, hair, fingers, and all parts of the body away from openings and moving parts. To reduce the risk of electrical shock, always use a 3-wire electrical system connected to the electrical ground. Whenever possible connect the machine to an outlet protected by a ground fault interrupter (GFCI). See “Grounding Instructions.”

IMPORTANT INSTRUCTIONS
  • Before use the equipment must be correctly assembled with all of its components
  • Check that the electrical outlet is correct for use with the plug on the machine
  • Before connecting, check that the specified motor voltage corresponds to the main voltage available
  • Never use the equipment near flammable, explosive, or toxic substances: sparks from the motor could cause dangerous reactions.
  • Always unplug the machine from the electrical outlet when leaving the machine unattended or before attempting any repair.
  • Service and repair should be done by qualified personnel only. Use only the original manufacturer’s replacement parts.

Operation

This machine is a commercial vacuum designed for dry pick-up only. And must be stored in a dry location.

Atrix ATIBCV Antimicrobial100 Cleanroom HEPA Vacuum Guide fig 1

  1. Attach the paper bag to the tank inlet deflector. See Figure 1.
  2. Ensure that the cartridge filter is securely attached to the bottom of the vacuum head. See Figure 2.
  3. Stretch-treated pre-filter over the HEPA cartridge filter. See Figure 2.
  4. Attach the filter retainer using the 2 mounting screws.
  5. Place the vacuum head onto the tank and secure it with the two clamps.
  6. Insert the hose into the tank inlet until it locks in place. See Figure 3.
  7. Attach appropriate cleaning tools.
  8. Activate the vacuum by pressing the switch on the vacuum
    head.

After Use

  1. Store the cord on the hook.
  2. Store the appliance indoors, away from sources of heat.
  3. This appliance is provided with an automatically reset thermal limiter to avoid damage to the motor. If the thermal limiter operates do one or more of the following:
    • Change the bag
    • Clean or replace the cartridge filter
    • Check the hose and tank inlet for any obstructions
    • Wait a few minutes for the thermal limiter to re-close the circuit.

Atrix ATIBCV Antimicrobial100 Cleanroom HEPA Vacuum Guide fig 2

Atrix ATIBCV Antimicrobial100 Cleanroom HEPA Vacuum Guide fig 3

Tank and Cart Assembly ATIBCV

Tank Assembly 

Atrix ATIBCV Antimicrobial100 Cleanroom HEPA Vacuum Guide fig 4

Atrix ATIBCV Antimicrobial100 Cleanroom HEPA Vacuum Guide fig 5

Cart Assembly 

Atrix ATIBCV Antimicrobial100 Cleanroom HEPA Vacuum Guide fig 6

Tools 

Atrix ATIBCV Antimicrobial100 Cleanroom HEPA Vacuum Guide fig 7

Atrix ATIBCV Antimicrobial100 Cleanroom HEPA Vacuum Guide fig 8

Filters

  • ATIBCVBAG: Paper Bags, 5/pkg
  • ATIBCVH1: Hepa Filter, Cartridge Main
  • ATIBCVH2: Hepa Filter, Cartridge Exhaust
  • ATIBCVSF: Pre-Filter, Treated

Warranty Policy

Atrix International warrants new cleaning equipment against defects in material and workmanship under normal use and service to the original purchaser as detailed below.

3 years
Subject to the conditions stated below, Atrix International warrants all Polyethylene Tanks to be free from defects in materials and workmanship for a 3-year period. Parts replaced or repaired are warranted for the remainder of the original warranty period.

1 year

Subject to the conditions stated below, Atrix International warrants all other cleaning equipment components to be free from defects in materials and workmanship for a 1- year period. Parts replaced or repaired are warranted for the remainder of the original warranty period. Atrix International will furnish and charge for replacement parts, including transportation, to the original owner.

If the part is returned within 30 days and is found defective, the owner will be credited for the cost of the replacement part including shipping and handling. Wear items exempt from warranty include belts, carbon brushes, power cords, wheels, brushes, pads, handle grips, filters, screens, hoses, and squeegees.

This warranty shall not apply to failures caused by misuse or abuse, improper maintenance as stated in the operation manuals, use of unauthorized repair parts, repairs by other than Atrix International, and damage in transit. Atrix International disclaims and denies any liability for any direct, indirect, special incidental, or consequential damage that may be suffered as a result of the sale, delivery, servicing, use, loss of any product, downtime, labor, freight, or other charges not expressly included herein. Register your warranty at www.atrix.com.