Honeywell CL30XC Evaporative Air Cooler Manual featured img

Honeywell CL30XC Evaporative Air Cooler Manual

Honeywell logo

Honeywell CL30XC Evaporative Air Cooler Manual

Honeywell CL30XC Evaporative Air Cooler Manual product img

PARTS DESCRIPTION

Honeywell CL30XC Evaporative Air Cooler Manual fig 1

  1. Control Panel
  2. Handle
  3. Louvers
  4. Water Tank
  5. Power Cord & Plug
  6. Casters
  7. Ice Compartment Lid
  8. Rear Grill
  9. Water Level Indicator
  10. Remote Contro
  11. Detachable Water Tank Latch
  12. Water Fill Door
  13. Drain Plug
  14. Water Regulator

CONTROL PANEL

Honeywell CL30XC Evaporative Air Cooler Manual fig 2

Icons on Display Screen

  • Honeywell CL30XC Evaporative Air Cooler Manual fig 3the low water level in the tank
  • Honeywell CL30XC Evaporative Air Cooler Manual fig 4Cool
  • Honeywell CL30XC Evaporative Air Cooler Manual fig 5Fan speed
  • Honeywell CL30XC Evaporative Air Cooler Manual fig 11Sleep
  • Honeywell CL30XC Evaporative Air Cooler Manual fig 6Low speed
  • Honeywell CL30XC Evaporative Air Cooler Manual fig 7Medium speed
  • Honeywell CL30XC Evaporative Air Cooler Manual fig 8High speed
  • Honeywell CL30XC Evaporative Air Cooler Manual fig 10Swing
  • Honeywell CL30XC Evaporative Air Cooler Manual fig 9Timer

FUNCTION BUTTONS

POWER
Press theHoneywell CL30XC Evaporative Air Cooler Manual fig 17 button to turn the unit on. The cooler will start automatically at medium speed. After a few seconds, the speed will switch to low. To turn the unit off, press the button again.

SPEED
Press the SPEED button repeatedly to change the speed between High – Medium – Low. The indicator light will show the selected speed:

Honeywell CL30XC Evaporative Air Cooler Manual fig 12

COOL
Press the COOL button untilHoneywell CL30XC Evaporative Air Cooler Manual fig 4is illuminated on the display screen. This activates evaporative cooling. The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet. When theHoneywell CL30XC Evaporative Air Cooler Manual fig 4

is not illuminated on the display screen, the unit switches to a fan-only mode, without evaporative cooling.

WARNING:
Please ensure sufficient water is in the water tank otherwise you may hear a Low Water Alarm and the cooler will start in a Fan only mode without evaporative cooling.

TIMER
Press the TIMER button until the desired time duration setting is selected. When the set time has passed, the unit will automatically turn off (the unit remains in Standby mode until the power cord is unplugged from the electrical socket). The TIMER function allows you to program the unit for up to 8 hours of use.

SWING

Honeywell CL30XC Evaporative Air Cooler Manual fig 13

Press the SWING button untilHoneywell CL30XC Evaporative Air Cooler Manual fig 10is illuminated on the display screen. The louvers will begin to move left to right automatically. Vertical Air Flow – You can manually adjust the louvers to change the vertical airflow.

SLEEP
Press the SLEEP button untilHoneywell CL30XC Evaporative Air Cooler Manual fig 11is illuminated on the display screen. When the SLEEP mode is selected, the fan will run on High for one hour, then Medium for the second hour, and on Low speed from the third hour onwards until you switch off the unit.

REMOTE CONTROL
Honeywell CL30XC Evaporative Air Cooler Manual fig 14

  • POWER: ON / OFF
  • SPEED: Low / Medium / High
  • COOL: Evaporative Cooling On/Off
  • SWING: Controls the motion of the louvers
  • TIMER: Controls the Timer function for automatic off
  • SLEEP: Turns on Sleep mode

Note:

  • The remote control requires AAA (2 x 1.5V) batteries for replacement.
  • Open the battery compartment at the back of the remote control and insert the batteries inside. Care must be taken to insert the batteries according to the correct polarity (+ / –) markings shown inside the battery compartment.
  • Always point the remote control signal transmitter towards the unit when operating. Make sure that the signal path is not obstructed.
  • Remove the batteries if the unit is not going to be used for an extended period of time.
  • Do not drop the remote control.
  • Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries.
  • Do not mix old and new batteries.
  • Do not recharge the battery. Exhausted batteries are to be removed from the product and safely disposed of as per local regulations.

COOLER LOCATION
Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide.

FILLING WITH WATER

CAUTION:
Unplug the unit from the electrical power outlet before emptying or refilling the water tank.

Honeywell CL30XC Evaporative Air Cooler Manual fig 15

Open the Water Fill Door located on the side of the unit. The Water Level Indicator is located at the side of the unit. Refill the water tank when the water level is low. Do not fill water above the “Max.” water level mark to avoid water droplets collecting on the louvers. Check the water level in the tank before running the COOL function. Make sure that the water in the tank is above the minimum water level mark. Running the unit in COOL mode with inadequate water may cause pump failure.

Note:
The water capacity refers to the total volume of water that can be contained within the air cooler water tank and water distribution system. The water capacity in the tank at the “Max.” indicator level may be lower than the actual water capacity of the air cooler.

LOW WATER ALARM
The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the minimum level, you will hear a beeping sound and the will flash continuously. The unit will automatically pause evaporative cooling. Refill the water tank to deactivate the alarm in cooling mode. First, switch OFF the unit and unplug it from the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch ON again.

To deactivate the alarm and continue using the unit as a fan (without evaporative cooling), switch the unit OFF and then ON again. The Low Water Alarm will not activate in Fan only mode. The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty.

CLEANING & DRAINING THE WATER TANK

If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide.

WARNING:
Before cleaning the unit, switch the unit OFF and disconnect it from the power outlet

  • Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty.
  • Detach the water tank by unlocking the Detachable Water Tank Latches on both sides of the unit. Lift the cooler upwards away from the base and place it carefully and vertically on the floor. Be careful not to bend the water pump tubes and other parts that will hang from the bottom of the unit when the body is removed from the tank.
  • Refill the water tank with clean water and drain it completely. Clean the water tank with dish detergent or a damp cloth and rinse it thoroughly.
  • Refill the water tank with clean water, up to the maximum level.
  • Replace the top of the air cooler carefully back onto the tank and lock the side latches. The air cooler is now ready to be used.
  • Use a damp cloth to remove dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
  • When the product is not in use, store the unit in a dry place out of direct sunlight
CLEANING THE CARBON DUST FILTER* AND HONEYCOMB COOLING MEDIA
  • The appliance is supplied with a Carbon Dust Filter* & Honeycomb Cooling Media.
  • The Carbon Dust Filter* and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance.
  • Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill it with fresh water, especially if the tank has not been cleaned in a long time

Honeywell CL30XC Evaporative Air Cooler Manual fig 16

Removing the Carbon Dust Filter*/ Honeycomb Cooling Media:

  1. Remove all the screws from the Rear Grill of the Air Cooler.
  2. Carefully pull out the rear grill from the cooler.
  3. Slide out the Carbon Dust Filter* and clean it with water.
  4. The Honeycomb Cooling Media is secured on the Honeycomb Frame by a Horizontal Bar that is fixed in place by two screws. Remove these two screws to release the Horizontal Bar and slide the Honeycomb out of the frame.
  5. Replace or clean media with water and a damp cloth as needed.

WARNING:
DO NOT operate the Air Cooler when the Rear Grill or Honeycomb Frame is removed from the Air Cooler, or if there is a loose-fitting Rear Grill or Honeycomb Frame. Doing so can cause serious injury or dangerous electrical shock.