Introduction

Thanks for purchasing LifeSmart HVAC gateway, which can easily turned your central AC to become Smart and controller remotely. Now the gateway has already supported Daikin, Toshiba, Hitachi, Mitsubishi, Hisense, Haier , Panasonic, York , Midea, LG , BOSCH, GREE and etc. The supported references are refreshed continually, details please find sales person for suppot. Please review this document before installed.

SPEC

Item SPEC
Input Power DC 12V
Consumption Below 1.2W
Working
Environment
Temp :0~40℃
Humidity :20~85%
Gateway port RJ45

Installation

Outlooking Size & Installation Environment

Installed indoor only and installed hidden

LifeSmart-HVAC-Central-AC-Smart-Gateway-feature

Components

LifeSmart-HVAC-Central-AC-Smart-Gateway-fig2

  1. Display:Show the contents of communication, display the related parameter like connected HVAC brandings and Qty of indoor machines.
  2. LED indicator:Show status of the Gateway
  3. Buttons:Functional buttons to set up parameters and page up/down functions.
  4. AIR CON Terminals:For different protocol terminals. (5、6、7、8)are terminals for other bus protocol.
  5. CONFIG 1 :Dialing terminals( RED) is interface for choosing AIR Con brandings.
  6. CONFIG 2:Dialing terminals ( BLUE) is interface for better communication for AIR Con.
  7. POWER Interface: For Power Supply .PS: Power supply is DC12V. Unfit power supply will cause damage for the device.

PS 1:LED indicator:
HBS:When AC communication detected, the indicator will light up. It will flicker though the AC communication rhythm.
STA:It will keep dark,while device running normally to search AC

LifeSmart-HVAC-Central-AC-Smart-Gateway-fig3

LifeSmart-HVAC-Central-AC-Smart-Gateway-fig4

Installation of Daikin outdoor / indoor machine should be done by professional HVAC installers. The communication wire between gateway and HVAC should be:2-core STP (Shielded twisted pair) , more than 0.75mm2,under 100,

Wiring Installation Tips

  • Different brandings and references, wiring interface is different ( Please check the dialing and interface program) 。
  • Please use DC 12V to power the gateway.。
  • Improper power connection will cause damage to device。
  • Please power off the HVAC and gateway when install or repair
  • Better NOT put communication wire together with the power line to avoid the unexpected disturb. If there is not enough space, please grantee the communication wire distance between gateway and other wire more than 30cm.
  • If wrongly connect the power line with signal terminal, it will cause fuse burn , please contract LifeSmart .

Hardware Configuration

Preparation

  • Make sure HVAC is on power, including all outdoor / indoor machines.
  • Make sure all functions working well without alarm or report.
  • Distribute network address to each indoor machine. (For all series of Daikin and Toshiba, we need to distribute address manually. For other brandings with only 1 outdoor machine, the indoor machines are distributed automatically)
  • Connect the gateway and HVAC interface as below chart guidance

Terminal Choose and Communication pairing

LifeSmart-HVAC-Central-AC-Smart-Gateway-fig4

Notice:Improper dialing may cause devices not working. Please consult LifeSmart Service Engineer before making any change to dialing terminals. CONFIG 2:Dialing terminals ( BLUE) is interface for better communication for AIR Con.

  • Dialing Terminals and communication terminals for different brandings.

LifeSmart-HVAC-Central-AC-Smart-Gateway-fig5

LifeSmart-HVAC-Central-AC-Smart-Gateway-fig5

Display and button user manual and LED Indicator Instruction

  • Once the gateway powered with DC 12V , it starts initialization.
  • The initialiaztion will continue like 20secons, and change to “ Able to reset “ status . Right now the LCD display shows “ Right now, you can press set button 5seconds to reset “ Normally if you don’t need reset, wait 20seconds than jump automatically.
  • Start seraching HVAC, right now LCD display show “ Searching HVAC …. It takes 2-5 minutes
  • After searching ends, on the display page , there will be information about the HVAC. You can use rolling up/ down button to see full information.

APP Instruction

  • Make sure you have a LifeSmart Account and with a Smart Station under the account
  • Please click the “add devices in APP, and choose the HVAC Gateway
  • Back to home page, click left corner LifeSmart – General – All devise – Smart Station – HVAC Gateway – Settings, then slide from right to left at No.1 Address, sync, and choose all groups to retrieve all indoor machines group
  • It will takes about 1-10 minutes at 1st time to sync devices on home page (The devices will show as grey) , then rename each AC device.

REFRENCE LINK

https://iot.ilifesmart.com/room-climate/central-ac-smart-gateway.html