Wireless Commercial Keypads are security keypads and should be programmed to ONE operator. The Wireless Commercial Keypad comes with one 9V Lithium battery, instructions, and two keys.  A long tone will sound. If an invalid PIN or partial PIN is accidentally entered, an error tone will sound. The Wireless Commercial Keypad is compatible with the brands of commercial door and gate operators listed in the table below.

LiftMaster-KPW5-Wireless-5-Code-Commercial-Keypad-User-Guide-Image-1

LiftMaster-KPW5-Wireless-5-Code-Commercial-Keypad-User-GuideKPW5

LiftMaster-KPW5-Wireless-5-Code-Commercial-Keypad-User-Guide-Image-2KPW250

INSTALLATION

WARNING: This product can expose you to chemicals including lead, which are known to the State of California to
cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  1.  The mounting location needs to be in line of sight of the moving gate.
  2.  Unlock and remove the face plate from the mounting plate.
  3.  Mount the mounting plate to the desired surface and secure with 1/4″ screws or bolts (not provided).
  4.  Remove the battery cover using a Phillips screw driver. Install the battery (provided) and re-install inner cover.
  5. Reattach the face plate to the mounting plate and lock with the key.

LiftMaster-KPW5-Wireless-5-Code-Commercial-Keypad-User-Guide-Image-3

BASIC PROGRAMMING

The keypad back light will remain on if the product is in programming mode.  After 60 seconds of inactivity, the keypad will exit the programming mode. The 6-digit Master Code is used to prevent unauthorized access to the system. A Master Code is required to operate the Wireless Commercial Keypad. It
is highly recommended to change and record your unique Master Code.

Set Master Code

LiftMaster-KPW5-Wireless-5-Code-Commercial-Keypad-User-Guide-Image-4

Program a PIN

LiftMaster-KPW5-Wireless-5-Code-Commercial-Keypad-User-Guide-Image-5

PROGRAM TO OPERATOR

Program to LiftMaster Operator
  1. Enter program mode: * (Master Code) #.
  2.  Set frequency and encryption (KPW250 only):
  •  LiftMaster Security+ 315 MHz – Press 03 # 2 #. A long tone will sound.
  •  LiftMaster Security+ 390 MHz – Press 03 # 3 #. A long tone will sound.
  •  To reset factory default – Press 03 # 1 #. A long tone will sound.
Program to Linear Multi-Code Receiver KPW250 ONLY
  1.  Locate the DIP switch sequence on the operator and record it. If DIP switch is in the “up” or “on” (CLOSED)position place a 1, “down” or “off” (OPEN) position place a 0 in the corresponding box in the chart below.

DIP Switch Sequence                  1   2   3  4  5  6   7  8  9  10
UP / ON (CLOSED)
DOWN / OFF (OPEN)

NOTE: Leave any unused switch locations blank.

  1.  Enter program mode: * (Master Code) #. A long tone will sound.
  2.  Set Linear Multi-Code frequency and encryption: Press 03 # 4 #. A long tone will sound.
  3.  Enter the DIP Switch sequence (Use ONLY 1 and 0). Press #. A long tone will sound.
  4.  Exit Program Mode: * * #.
  5.  Press the Learn Button on the operator.

ADDITIONAL PROGRAMMING

Reset Master Code

Resetting the Master Code will not remove PINs or temporary PINs from memory and will not change the frequency and encryption type.  To reset the Master Code to the factory default (888888):

  1.  Unlock and remove the face plate.
Reset Keypad

Resetting the keypad will erase the Master Code, all permanent PINs, all temporary PINs, and frequency and encryption settings.  To reset the keypad:

  1.  Unlock and remove the face plate.
  2.  Press and hold RESET button on the control board for 15 seconds, 3 long tones will sound indicating the keypad has been reset.
Lockout Mode (Default is ON)

If the keypad receives five consecutive invalid PINs, the keypad will enter lockout mode and will not accept any keypad inputs for 30 seconds. After 30 seconds, the keypad will begin accepting new inputs.

Constant Pressure Override (CPO)

External entrapment protection devices include LiftMaster monitored photoelectric sensors and LiftMaster monitored wired and wireless safety edge sensors. Be sure to repair or replace these devices promptly if they are not working properly. CPO is only compatible with LiftMaster UL 325 Compliant Gate Operators (with burgundy boards) that require monitored
entrapment protection.

To use Constant Pressure Override
  1.  Enter a valid 4-digit PIN.
  2.  Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion.

BATTERY

Warning

To prevent possible SERIOUS INJURY or DEATH:

  •  NEVER allow small children near batteries.
  •  If battery is swallowed, immediately notify doctor.

The 9V Lithium battery should produce power for up to 5 years. To replace the battery:

  1.  Unlock and remove the face plate from the mounting plate.
  2.  Remove the battery cover using a Phillips screw driver.
  3.  Remove the old battery and install new 9V Lithium battery. Re-install inner cover.
  4. Reattach the face plate to the mounting plate and lock with the key.
  5.  Dispose of old battery properly

REPAIR PARTS

PART NUMBER                                       DESCRIPTION
K093A0763                                                    Mounting Plate
K107A0031                                                     Keys

TROUBLESHOOTING

LiftMaster-KPW5-Wireless-5-Code-Commercial-Keypad-User-Guide-Image-6

ONE YEAR LIMITED WARRANTY

LiftMaster warrants to the first consumer purchaser of this product that it is free from defect in materials and/or workmanship equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications  guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio.

FAQS

  1. What is the LiftMaster KPW5 Wireless Commercial Keypad?
    • The LiftMaster KPW5 is a wireless commercial keypad designed for access control. It allows authorized users to enter a secure area by entering a customizable access code.
  2. Where is the LiftMaster KPW5 typically used?
    • The KPW5 keypad is commonly used in commercial settings such as warehouses, offices, gated communities, and industrial facilities. It provides secure access control to these areas.
  3. How many access codes can the KPW5 keypad store?
    • The KPW5 keypad is designed to store up to 5 access codes, allowing you to grant entry to multiple authorized users while maintaining security.
  4. Is installation of the LiftMaster KPW5 keypad complicated?
    • Installation of the KPW5 keypad is typically straightforward and can be performed by a qualified technician. It typically involves mounting the keypad and connecting it to a compatible access control system.
  5. Is the KPW5 keypad weatherproof?
    • The weather resistance of the KPW5 keypad can vary depending on the specific model. Some models are designed to withstand exposure to the elements and are suitable for outdoor use. Check the product specifications to confirm the weatherproof rating of your model.

DOWNLOAD PDF

LiftMaster KPW5 Wireless 5 Code Commercial Keypad User Guide

REFERENCE LINK

https://www.liftmaster.com

Leave a Reply