INSTALLATION & OPERATION

THERMOSTAT LOCATION
For accurate temperature control and comfort, the correct location is very important. On new installations, the guidelines listed below should be followed as closely as possible. When replacing an old thermostat, install the new one in the same location unless these conditions suggest otherwise.

  1. Locate the thermostat on an inside wall about five feet above the floor, where it is easy to install and adjust. It should be in a room that is used often, such as a family room.
  2. Do not install it where there are unusual heating conditions, such as direct sunlight, close to a lamp, radio, television, radiator, register, near a fireplace, or other heat-producing appliance. Also, check for hot water pipes within the wall, or a stove on the other side of the wall.
  3. Do not locate in unusual cooling conditions, such as on an outside wall, or one separating an unheated room, or in drafts from stairwells, doors, or windows.
  4. Do not locate in a damp or humid area. This can shorten thermostat life due to corrosion.
  5. Do not locate where air circulation is poor, such as in a corner, alcove, or behind an open door.
  6. Do not install until all construction work and painting have been completed.

TOOLS REQUIRED
Wire stripper or knife, drill with ⅔6* bit, screwdriver, level, and a pencil.

SPECIFICATIONS

  • ELECTRICAL RATING .24 Vac (30 Vac Maximum)
  • SWITCH ACTION Open Contact Switch
  • ANTICIPATOR RATING… 0.15A to 1.2A
  • TEMPERATURE RANGE 5005 to 00°0

REMOVING OLD THERMOSTAT

Please read all instructions carefully. As you complete each step, check the adjoining square.

  • Disconnect the electricity and turn off the gas to the heater.
  • Remove the cover from the old thermostat.
  • Loosen all screws.
  • Disconnect wires from the thermostat, making sure they do not fall back inside the wall.
  • Strip insulation ⅜” from wire ends and clean off any corrosion.
  • Fill wall openings with non-combustible insulation to prevent drafts from affecting the thermostat.
  • Attach wires to terminal screws shown in Figure 2. (Either wire to either terminal) Push excess wire back into the wall opening. Find the anticipator setting on the old thermostat. The setting on the new thermostat should be the same.
  • Do this by carefully sliding the long pointer on the anticipator over the desired number. If the old anticipator setting cannot be determined, look at the gas control on the furnace, or set it at 6. During heating season, furnace should operate about five times an hour. If adjustments are necessary, move the heat anticipator pointer slightly and recheck. NOTE: Set pointer to 1.2 for millivolt systems.
  • Attach the front cover, Figure 1, to the base.
  • Turn electricity and gas back on and set pointer on top of thermostat to desired temperature.

LuxPro PSM30sa Heat Only Mechanical Thermostat User Manual fig 1

TECHNICAL SERVICE
If you have any problems installing or using this thermostat, please read the instructions carefully. Technical Service is available through our Technical Service number. If you require assistance, please call our offices between 8:00 a.m. and 4:30 p.m. Eastern Standard Time, Monday through Friday. The number is 856-234-8803. Please refer to model T10-1141

INSTALLING NEW THERMOSTAT

  • Place a new decorative wall plate (if supplied), Figure 3, over the wall opening. Decorative wall plates can optionally be left off.
  • Remove the Front Cover of the new thermostat by inserting a finger in the side of the thermostat and gently prying away each corner. Place Base, Figure 2, on the wall plate over the wall opening. Mark the wall with a pencil at mounting holes as shown in Figure 2. Now lay the wall plate and base to the side.
  • Drill two holes with ⅗6″ bit, 1″ deep.
  • Insert plastic screw anchors into drilled holes, flush with the wall surface.
  • Bring wires through a large hole in the decorative wall plate and through the Hole For Wires in the Base. Fasten the Base loosely to the wall using two mounting screws.
  • Place a level against the bottom of the Base, adjust until it is level, and then tighten the mounting screws to secure the Base.

WARRANTY

Warranty: If this unit fails because of defects in materials or workmanship within one year of the date of original purchase, Lux will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to one year from the date of the original purchase.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which the purchase was made, along with proof of purchase. Please refer to the Technical Service Section before returning the thermostat.

Purchaser assumes all risks and liability for incidental and consequential damage resulting from the installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.