GETTING STARTED

Thank you for supporting ecobee, the Smart Thermostat that provides your customers with freedom and flexibility
in managing their home environment.The ecobee Smart Thermostat has been designed in partnership with HVAC contractors to ensure the installation process is simple and efficient. This step-by-step Installation Manual will walk you through all aspects of the installation. To ensure an on-going service relationship with your customers, please register all of your ecobee Smart Thermostats in your Contractor Portal.

Before you begin

This manual explains the procedures for installing the ecobee Smart Thermostat beginning the installation. For information on how to operate the ecobee Smart Thermostat, please see the ecobee User’s Manual. The ecobee Smart Thermostat consists of two parts

  1.  A Smart Thermostat to be mounted on the homeowner’s wall.
  2. Ecobee-Smart-Thermostat-User-Manual-Image-1An Equipment Interface Module This should be mounted in the homeowner’s utility room and connects to the heating, cooling and ventilation equipment.

HVAC System compatibility information
ecobee is designed to operate low-voltage heating and cooling systems. It is not designed for use with line voltage or millivolt heating and cooling systems. ecobee supports control of up to four heating stages and two cooling stages.

Equipment Description
Gas/Oil/Electric heating (up to three stages)                        Yes
Heat pump with auxiliary heat (up to four stages)               Yes
Geothermal Heat Pump                                                               Yes
Duel fuel systems                                                                           Yes
Standard electric cooling (up to two stages)                             Yes
Boilers                                                                                                Yes
Central humidifier                                                                           Yes
Central dehumidifier                                                                       Yes
Heat Recovery Ventilator (HRV)                                                   Yes
Energy Recovery Ventilator (ERV)                                                Yes
Sensors with dry contact outputs                                                    Yes

Approvals
Optional Power supply meets EPA C.E.C Level IV and E.C CoC No Load power Consumption requirements.

FCC Compliance Statement
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment to an outlet on a different circuit from the receiver
  • Consult the dealer or an experienced radio/TV contractor for help.

Warning: Changes or modifications not expressly approved by ecobee Inc. could void the user’s authority to operate the equipment.

Specifications

Temperature ranges
Heat: 45 – 79°F (7 – 26°C)
Cool: 58 – 92°F (14 – 33°C)
Display: 40 – 100°F (5 – 37°C)
Sensitivity: +/- 1°F (0.5°C)
Operating: 32 – 160°F (0 – 70°C)

Humidity Range
Humidify: 20 to 50% R.H
Dehumidify: 30 to 60% R.H
Display: 0 – 90% R.H
Sensitivity: +/- 2% R.H.
Operating: 5 – 95% R.H

Dimensions
Smart Thermostat: 5.5”W x 3.25”H x 1”D (139.5mm H x 82.5mm W x 25mm D)
Equipment Interface: 4.6”W x 10”H x 1.3”D (118mm W x 254mm H x 32mm D)

Power
AC Transformer – 24 VAC – 3VA Minimum (not included), Optional Power Adaptor – 120V 50/60Hz to 12V DC 1A,
Battery – CR2032 – 3V lithium coin cell (included)

Terminal Description and Electrical Ratings
TerminalDescriptionVoltageCurrent max
Y1st stage cooling30V AC3A
W (O/B)1st stage heating (or changeover)30V AC3A
GFan30V AC3A
W2(AUX)2nd stage heating (or 1st auxiliary heat)30V AC3A
R/HHeat transformer return30V AC3A
R/CCool transformer return30V AC3A
ACC11st accessory relay30V AC3A
ACC1r1st accessory relay return30V AC3A
ACC22nd accessory relay30V AC3A
ACC2r2nd accessory relay return30V AC3A
ACC33rd accessory relay30V AC3A
ACC3r3rd accessory relay return30V AC3A
IN1 +Input 1 +Dry contact onlyDry contact only
IN1-Input 1 –Dry contact onlyDry contact only
IN2+Input 2 +Dry contact onlyDry contact only
IN2-Input 2-Dry contact onlyDry contact only
+12v12V DC power to thermostat8-14V DC600mA
GNDGND to thermostat
D+Data + communication line
D-Data – communication line

 

INSTALLING THE SMART THERMOSTAT

To install the Equipment Interface:
  1.   Make sure the surface is relatively flat and, if you are using a power adaptor, make sure there is
    an electrical outlet within five feet of where you plan to mount the device.
  2. Remove the front cover of the Equipment Interface. If necessary, Insert a flat-head screwdriver into one of the
    slots as shown below, and gently twist the screwdriver.
  3. Ecobee-Smart-Thermostat-User-Manual-Image-3Place the back of the enclosure on the intended mounting surface and use it as a template to mark the location of the mounting holes, as shown below.
  4. Ecobee-Smart-Thermostat-User-Manual-Image-4Move the back of the enclosure out of the way and make the holes where indicated in step 3. The mounting
    holes can accommodate a #6 pan-head screw.
  5.  Fasten the back plate to the wall using the appropriate screws (not included).
Wiring the Equipment Interface
  1. Disconnect the power to the heating and air conditioning equipment.
  2. Disconnect the wires going to the existing thermostat.
  3. Using the wiring diagrams on pages 9-11, connect the heating or air conditioning equipment to the Equipment Interface.
Wiring diagrams

Ecobee-Smart-Thermostat-User-Manual-Image-5

Ecobee-Smart-Thermostat-User-Manual-Image-6

Installing the Smart Thermostat

The ideal location for the Smart Thermostat is approximately five feet (1.5m) above floor level in the main living area. Do not install the Smart Thermostat:

  • In direct sunlight.
  • On exterior, non-insulated or poorly insulated walls.
  • In the kitchen or other areas of potentially high heat and/or humidity.
  • In an area that could restrict air flow.
To install the Smart Thermostat:
  1.  Remove the front cover of the Smart Thermostat, insert a flat-head screwdriver into one of the slots as
    shown below and gently twist the screwdriver.
  2. Ecobee-Smart-Thermostat-User-Manual-Image-2 Place the Smart Thermostat back plate on the wall.
  3.  Using the back plate as a template, mark the location of the mounting holes on the wall as shown below.
  4. Ecobee-Smart-Thermostat-User-Manual-Image-3Move the back plate out of the way and make holes where indicated in step 3. The mounting holes can
    accommodate a #6 pan-head screw.
  5.  Use drywall plugs or other screw anchors (not included) to ensure the Smart Thermostat can be mounted securely to the wall.
  6. Fasten the back plate to the wall using the appropriate screws (not included).

3-Year Limited Warranty

Ecobee warrants that for a period of three (3) years from the date of purchase by the consumer  the ecobee Smart Thermostat  shall be free of defects in materials and workmanship under normal use and service replace any defective Products, at no charge for labour or materials. Any replacement and/or repaired device customer’s credit card; or ship the defective Product directly to ecobee, in which case Customer shall contact ecobee directly shipping arrangements.

DOWNLOAD PDF

Ecobee Smart Thermostat With Voice Control User Manual

REFERENCE LINK

https://www.ecobee.com/

Leave a Reply