Insignia NS-AC12PWH8 12,000 BTU Air Conditioner FEATURED img

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner

Insignia-logo

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner product img

PACKAGE CONTENTS

  • 10,000 / 12,000 BTU portable air conditioner
  • Remote control with batteries (2)
  • Exhaust nozzle
  • Exhaust hose
  • Hose adapter
  • Window seal plate assembly
  • Quick Setup Guide

SAFETY INFORMATION

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this machine near water.
  6. Clean only with a damp cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If they provide plug does not fit into your outlet, consult an electrician for
    replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the
    point where they exit from the machine. 11 Do not attempt to modify or extend the power cord of this machine.
Additional precautions
  • This machine is intended for household use. Do not use it for any other purpose.
  • Use this machine indoors in a dry location only. Do not use it outdoors.
  • Do not place heavy objects on the machine, as this could damage it.
  • Wipe the machine with a soft cloth to clean it. Do not use wax, thinner, or irritating detergents.
  • Do not allow children or pets to drink the water discharged by the machine.
  • Do not disassemble or attempt to repair the machine yourself.
  • Do not plug this machine into an outlet with several other high electrical usage appliances.
  • Keep the machine away from heat sources and avoid direct sunlight.
  • If the machine is making a loud noise or producing an odor or smoke, switch off it, disconnect the plug, and immediately try to determine the cause.
  • Do not place heavy objects on the power cord to avoid it being crushed and causing an electric shock.
  • Do not put your fingers or hard objects into the outlet air guide bars.
  • Turn the machine off and unplug it if there is water inside it, then contact qualified service personnel for servicing.
  • Turn the machine off and unplug it before cleaning, moving, or servicing it.
  • To avoid injury, do not allow children or other individuals with special needs to touch or operate the machine. The machine should only be used with adult supervision.
  • Place the air conditioner on a flat surface and upright to ensure the normal operation of the compressor.
  • Do not use the machine near gasoline or other flammable liquids.

ELECTRICAL SAFETY

Integrated circuit breaker
For additional safety, the power cord on this air conditioner features an integrated circuit breaker. You can test and reset the circuit breaker using the buttons provided on the plug case. Consult a qualified electrician or service person if the grounding instructions are not completely understood, or if doubt exists as to whether the air conditioner is properly grounded.

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 1

The circuit breaker should be tested periodically by pressing the TEST button, then pressing the RESET button. If the TEST button does not cause the circuit breaker to trip, or if the RESET button does not stay engaged, unplug the air conditioner immediately and contact an Insignia technician.

 

Preferred grounding method 

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 2

Temporary grounding

Due to potential safety hazards, we strongly discourage the use of an adapter plug. If an adapter plug must be used for a temporary connection, use only a UL-listed adapter. The minimum capacity for 10,000 BTU is 120V, 60Hz, 13A, and 1560W, and for 12,000 BTU is 120V, 60Hz, 15A, and 1800W. Make sure that the large slot of the adapter is aligned with the large slot in the outlet.

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 3

FEATURES

  • 10,000 / 12,000 BTU
  • Programmable timer and remote control
  • 3-in-1 design (air conditioner, dehumidifier, fan)
  • Auto defrost
  • Digital controls with LED display
  • Auto On/Off
  • Multiple fan speeds with auto control

Front

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 4

Back

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 5

Control panel

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 6

Remote control

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 7

#ITEMDESCRIPTION
1Speed settingsPress to select the high, mid, or low setting.
2SwingPress to turn the swing function on or off.
3TimerPress to set the air conditioner to turn on or off automatically.
4▲(Up) and ▼(Down) buttonsCOOLING mode: Press to raise (▲) or lower (▼) the temperature setting.

TIMER mode: Press to turn the timer on (▲) or off (▼).

5CoolPress to set the air conditioner to cooling mode.
6DryPress to set the air conditioner to DRY mode.
7FanPress to turn on the air conditioner fan only (no cooling).
8AutoPress to set the air conditioner to AUTO mode.
9°C / °FPress to switch between Fahrenheit and Celsius.
10PowerPress to turn the air conditioner on or off.

 

INSTALLING YOUR AIR CONDITIONER

  1. Screw the exhaust hose to the air outlet on the back of your air conditioner, then screw the hose adapter to the other end of the hose.
    Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 10
  2. Measure the window size.
    Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 11
  3. Adjust the length of the window sealing plate to fit the window opening.
    Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 13
  4. Install the window sealing plate in the window opening and secure it with the screws provided.
    Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 14
  5. Insert the hose adapter into the vent panel, then slide it down or left until it clicks into place.
    Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 15
    Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 16
    1. For optimum performance, do not twist the venting hose. For better efficiency, shorten the hose, if possible
      Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 17
      Caution: The exhaust duct is designed especially for this air conditioner. Replacing or lengthening the duct could result in damage to your unit.
  6. If desired, install the security bracket with the type C screw
    Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 18

SETTING UP YOUR PORTABLE AIR CONDITIONER

Before using your portable air conditioner

  • Remove and store (optional) packing materials for reuse.
  • Remove any shipping tape before using the air conditioner.
  • Remove the tape residue with liquid dish soap and a damp cloth. Do not use sharp tools, alcohol, thinners, or abrasive cleaners to remove adhesive, which could damage the finish.

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 12

Placing your air conditioner

  • Place the unit on a flat, dry area near a window, so you can use the hose and diffuser to connect the air conditioner to the window installation kit in order to vent the exhaust air outside.
  • To maintain good air circulation and optimum machine performance, leave a 20 in. (50 cm) space around it

Running your air conditioner in DRY mode
If you want to continuously drain the water from your air conditioner and never have to manually drain the collection tank, see your online User Guide.

USING YOUR PORTABLE AIR CONDITIONER

Inserting the batteries in the remote control

  • Insert two AAA batteries (provided) into the remote control.
    Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 19

TURNING YOUR AIR CONDITIONER ON AND SELECTING THE MODE

  1. Press Power Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 20 to turn your air conditioner on.
  2. Press Mode  to select Cool, Fan, Dry, or Auto.
  3. n Cool or Fan modes, press Fan Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 21 to set the fan speed.
  4. In Cool or Dry modes, press Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 8 or Insignia NS-AC12PWH8 12,000 BTU Air Conditioner fig 9 to set the temperature.
  5. In Auto mode, the air conditioner function is determined by the ambient temperature. If the temperature is higher than 77° F (25° C), the air conditioner runs in cooling mode. If lower than 77° F (25° C), the air conditioner runs in fan mode.

TROUBLESHOOTING

For troubleshooting information see your online User Guide.

SPECIFICATIONS
For specifications see your online User Guide.

ONE-YEAR LIMITED WARRANTY
Visit www.insigniaproducts.com for details or see your online User Guide.

CONTACT INSIGNIA:
For customer service, call 1-877-467-4289 (U.S. and Canada) or 01-800-926-3000 (Mexico) www.insigniaproducts.com

INSIGNIA is a trademark of Best Buy and its affiliated companies Distributed by Best Buy Purchasing, LLC 7601 Penn Ave South, Richfield, MN 55423 U.S.A. ©2016 Best Buy. All rights reserved. Made in China

REFERENCE LINK

https://www.insigniaproducts.com/pdp/NS-AC12PWH9/6145112

DOWNLOAD LINK

Insignia NS-AC12PWH8 12,000 BTU Air Conditioner

Leave a Reply