IMPORTANT SAFETY INSTRUCTIONS

  • Before use, ensure that all packaging materials are removed and that there is no visible damage to the unit or accessories. When in doubt, do not use the unit and contact customer service.
  • Always place the daylight lamp on a flat, level, stable, hard surface.
  • Do not immerse the unit in the water and do not use it in wet rooms such as a bathroom, laundry room, or pool area.
  • Do not use after taking painkillers or drugs or drinking alcohol.
  • Keep children away from packaging materials (risk of suffocation).
  • Do not cover or store the unit while it is warm.
  • Always unplug the power adapter and allow the device to cool down before touching it.
  • Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the unit. Operate only when the unit is completely dry.
  • Ensure that you only insert and remove the power adapter with dry hands and that you only press the ON/OFF button with dry hands.
  • Keep the power cord away from heated objects and flames.
  • Protect the unit from strong impacts.
  • Do not disconnect the power adapter from the electrical outlet by pulling on the cord.
  • Do not use the device in the presence of flammable anesthetic gas connections with air, oxygen, or nitrogen oxide.
  • This product has no user-serviceable parts; return the product to customer service for any repair or replacement.

Included in delivery

Check that the exterior of the cardboard delivery packaging is intact and make sure that all contents are present. Before use, ensure that there is no visible damage to the devices or accessories and that all packaging material has been removed. If you have any doubts, do not use the device and contact your retailer or the specified Customer Service address.

BEURER HA 85 Pair Digital Amplifiers Fig 1

  • 2 x HA 85 digital hearing amplifiers
  • 8 x earplugs (in different sizes and designs)
  • 2 x interchangeable batteries
  • 1 x cleaning brush
  • 1 x drying capsule
  • 1 x storage box with charging function
  • 1 x instructions for use

Signs and symbols

The following symbols are used on the device, in these instructions for use, on the packaging and on the type plate for the device:

BEURER HA 85 Pair Digital Amplifiers Fig 2

Warnings and safety notes

  • You must have your hearing checked by a doctor or qualified hearing care professional before using the hearing amplifiers. The settings of the hearing amplifiers should only be adjusted by a trained expert, for example an ENT specialist, an audiologist or a qualified hearing amplifier retailer.
  • In the event of an existing or previous ear problem, you should consult your doctor before using
    the hearing amplifiers.
  • Use for patients suffering from an ear inflammation or infection is NOT permissible.
  • Do NOT use the hearing amplifiers if you are suffering from an inflammation of the middle ear or ear canal.
  • If you feel unwell or experience pain when wearing the hearing amplifiers, stop using them immediately and contact your doctor.
  • If your ear becomes inflamed or your skin irritated or you experience an increased accumulation of earwax when wearing the hearing amplifiers, stop using them immediately and contact your doctor.

Intended use

The hearing amplifiers are only to be used to help people to hear better. The devices are only intended for the purpose described in these instructions for use. The manufacturer is not liable for damage resulting from improper or careless use.

Device description

Hearing amplifier

BEURER HA 85 Pair Digital Amplifiers Fig 3

  1. Minus button
  2. Plus button
  3. Program selection button
  4. Microphone
  5. RIC sound tube
  6. Fixing tube
  7. Speaker
  8. Earwax guard
  9. Earplug
  10. Interchangeable battery

Initial use

Remove the hearing amplifiers from the packaging and check that the devices and all accessories are included and not damaged. Charging the hearing amplifiers with the storage box with charging function To charge the devices and batteries, connect the mains part to a socket, plug in the supplied micro-USB cable and connect it with your storage box with charging function.

Flashing green light:
Devices and batteries are charging.
Permanent green light:
Devices and batteries are fully charged.

Usage

Adjusting your hearing amplifier

  1. The hearing tubes are printed with “2B” in red and blue respectively. “Red” is for the right and “blue” is for the left ear.
    BEURER HA 85 Pair Digital Amplifiers Fig 4
  2. Attach the earplug to the sound tube by pushing it over the grooves on the tube until it sits securely in place.
    BEURER HA 85 Pair Digital Amplifiers Fig 5
  3. Place the hearing amplifier case behind your ear. The curved part of the sound tube should sit comfortably on the ear (next to the arm of the glasses for glasses wearers).
    BEURER HA 85 Pair Digital Amplifiers Fig 6
  4. Hold the sound tube in place and carefully position the earplug in the ear canal. Make sure not to insert the earplug too deeply into the ear canal. If the earplug is not properly in place or feels uncomfortable, try a different earplug.
    BEURER HA 85 Pair Digital Amplifiers Fig 7
  5. Place the fixing tube along your outer ear. This ensures the earplug sits more tightly in your ear. If the fixing tube bothers you, you can remove it at the connecting point to the speaker. It is not absolutely necessary.
    BEURER HA 85 Pair Digital Amplifiers Fig 8

Cleaning and maintenance

  • Always keep the hearing amplifier clean.
  • Always treat the products with care and prevent the earplug and microphone from becoming blocked with foreign matter. This impairs the function of sound amplification.
  • Clean the hearing amplifiers and earplugs with a clean, dry cloth after each use. Never use abrasive, corrosive or solvent-based cleaning products. 44
  • Under no circumstances should you hold the hearing amplifier underwater, as this can cause liquid to enter and damage the hearing amplifier.
  • The supplied cleaning brush is suitable for removing earwax stuck in the earplug (see device description).
  • Allow the hearing amplifier to dry fully after cleaning. Store the hearing amplifiers in a safe, dry, and clean place in the relevant storage box with a charging function with the drying capsule.
  • The drying capsule has to be replaced if the color of the granulate changes from orange to white (you can find out where to obtain a new drying capsule in section “9. Accessories and replacement parts”).
  • If this is the case, replace the earwax guard (you can find out where to obtain a new earwax guard in section “9. Accessories and replacement parts”).

Accessories and replacement parts

Accessories and replacement parts are available from the corresponding listed service address under the stated material number.

BEURER HA 85 Pair Digital Amplifiers Fig 9

REFERENCE

https://www.beurer.com/web/us/products/medical/hearing-amplifiers/ha-85.php

DOWNLOAD PDF

641.21_HA85 Pair_med_2020-11-18_03_IM1a_BEU_compressed

Leave a Reply