Shark LA481 Lift-Away ADV Upright Vacuum Owner Guide

 

 

 

 

LiftAway® ADV Upright

Vacuum with PowerFins® HairPro™ and Odor Neutralizer Technology

 

LA481 Series

OWNER’S GUIDE

 

IMPORTANT SAFETY INSTRUCTIONS

FOR HOUSEHOLD USE ONLY

 

WARNING

To reduce the risk of fire, electric shock, injury, or property damage, when using

an electrical appliance, basic precautions should always be followed, including the following:

17. Keep nozzle and all vacuum openings away from hair, face, fingers, uncovered feet, or loose clothing.
  1. DO  NOT  use if vacuum cleaner is notworking as it should, or has been dropped, damaged, left outdoors, or dropped into
  2. Useextra care when cleaning on
  3. DO NOT leavethe vacuum cleaner

ODOR

27. Observe the following when interacting with the Odor Neutralizer Technology cartridge.
  1. DO NOT attempt to disassemble Odor Neutralizer Technology cartridge.
  2. Avoid direct contact with the fragrancepod in the

 

READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM

  1. Inspect power cord and plug for any damage before use. DO NOT use vacuumcleaner with a damaged cord or plug. Turn off all controls before plugging in or unplugging the vacuum cleaner. Store your vacuum cleaner with the power cord secured around the two cord  To minimize

the risk of power cord damage, do not allow the motorized brush roll to ingest the cord. If this occurs, immediately shut off power to the vacuum and remove the cord.

  1. This appliance has a polarized plug. If the plug does not fit fully into the outlet, reverse the plug (one blade is wider than the other). If it still does not fit, contact a qualified electrician. DO NOT force into outlet or try to modify to
  2. This appliance can be used by persons with reduced physical, sensory, or mental capabilities or lackof experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards

Cleaning and user maintenance shall not be made by children. Keep the appliance and its cord out of reach of children. DO NOT allow the appliance to be used by children. DO NOT allow to be used as a toy. Close supervision is necessary when used near children.

  1. Always turn off the vacuum cleaner before connecting or disconnecting anymotorized nozzles, hose, or other accessories.
  2. DO NOT handle plug orvacuum cleaner with wet
  3. DO NOT usewithout filters in

unattended while plugged in.

  1. Whenpowered on, keep the vacuum cleaner moving over the carpet surface at all times to avoid damaging the carpet
  2. DO NOT place vacuum cleaneron unstable surfaces such as chairs or
  3. YourShark® vacuum may not

be designed to stand up on its own. When taking a break from cleaning, you may need to lean it against furniture or a wall, or lay it flat

on the floor. Using the vacuum

for an application where the unit lacks stability may result in personal injury.

  1. DO NOT use to pickup:
a) Liquids
  1. Largeobjects
  2. Hardor sharp objects

(glass, nails, screws, or coins)

  1. Largequantities of dust (drywall
  1. DO NOT directly inhale fromthe Odor Neutralizer Technology cartridge.
  2. Keepaway from children and
  3. Keep away from heat, sparks,and open
  4. DO NOT place in direct
FRAGRANCE CARTRIDGE FIRST AID
a) Avoid contact with fabrics and finished surfaces.
  1. Eyecontact: Remove contact lenses if Rinse continuously with water for several minutes.
  2. Skin contact: Wash hands thoroughly after handling. If irritation or rash develops, seek medicaladvice/attention.
  3. Inhalation:Move person to fresh air if they are experiencing any respiratory  If symptoms persist, seek medical advice/

 

  1.    Your vacuum cleaner may consist of a motorized nozzle, wand, hose,and/ or vacuum pod. This device contains electrical connections,electrical
  2. Onlyuse Shark® branded filters and
  3. DO NOT damage the powercord:
dust, fireplace ash, or embers).

DO NOT use as an attachment to power tools for dust collection.

  1. Smokingor burning objects

e)

 

28.
attention.

Ingestion: DO NOT induce vomiting. Seek medical advice/ attention.

 

wiring, and moving parts that potentially present risk to the user. The hose contains electrical wires. Do not use when damaged, cut, or punctured.

  1. Use only identical replacement
  2. Carefully observe and follow the instructionsprovided below to avoid improper use of the
  3. DO NOT pull or carryvacuum
cleaner by the cord or use the cord as a handle.
  1. DONOT unplug by pulling on  Grasp the plug, not the cord.
  2. DO NOT run the vacuum cleaner overthe power cord, close a door on the cord, pull the cord around sharp corners, or leave the cord

(hot coals, cigarette butts,

or matches)

  1. Flammable or combustible materials(lighter fluid, gasoline, or kerosene)
  2. Toxic materials (chlorine bleach, ammonia, or draincleaner)
  1. DONOT use in the following areas:
a) Poorly lit areas

Unplug from electrical outlet when not

in use and before any maintenance or cleaning.

  1. Hand wash with water only. Washingwith cleaning chemicals could damage the
  2. During cleaning or routine maintenance, DO NOT cut anything otherthan hair, fibers, or string

 

DO NOT use the vacuum for any purpose other than those described in this manual.

  1. Before use, carefully inspect all parts

near heated surfaces.

  1. DO NOT put any objects into nozzle or accessory openings.DO NOT use with any opening blocked; keep free
    1. Wet or dampsurfaces
    2. Outdoorareas
    3. Spacesthat are enclosed and may contain explosive or toxic fumes

31.

wrapped around the brushroll.

Allow all filters to air-dry completely before replacing in the vacuum to prevent liquid from being drawn into

 

for any damage. DO NOT use if any

parts are damaged.
  1. Theuse of an extension cord is

NOT recommended.

8. This vacuum cleaner contains no serviceable parts.

of dust, lint, hair, and anything that

may reduce airflow.

  1. DO NOT use if nozzle or accessory airflowisrestricted. If the air paths or the motorized floor nozzle become blocked, turn the vacuum cleaner

off and unplug from electrical outlet.

or vapors (lighter fluid, gasoline, kerosene, paint, paint thinners, mothproofing substances, or flammable dust).

  1. Turnoff all controls before plugging in or unplugging the vacuum.

electric parts.

  1. Make sure the dust cup and all filters are in place after routine
  2. If provided, secure the power cord around the two cord hooks during

 

Remove all obstructions before you plug in and turn on the unit again.

SAVE THESE INSTRUCTIONS

 

  ASSEMBLY ASSEMBLY

 

 

 

 

 

 

 

6

(Turn to Click)

 

 

 

 

 

 

1

(Click)

 

  POWER CORD

 

 

 

 

 

 

  1. Place Pod down onto
  2. Insert Wand into
  3. Insert Handle into
  4. Attach Hose to back of
  5. Remove Odor Neutralizer Technology Dial from bag. Flip up the dial handle, alignthe teal arrows, then insert the dial into the
  6. To lock and engage the dial, rotate it counterclockwise until it clicks into thedesired odor intensity

 

* More detailed Odor Neutralizer Technology assembly instructions and visuals on the following two pages.

 

IMPORTANT: For proper operation, ensure all connections are securely clicked into place.

 

 

 

 

 

 

 

 

For cord access, rotate upper hook down and remove cord.

 

 

 

 

 

 

 

 

Use cord holder on the side of wand to hold cord in place while vacuuming.

 

  TECHNOLOGY SETTINGS

  SETTINGS

  ODOR  NEUTRALIZER TECHNOLOGY

  ODOR CARTRIDGE REPLACEMENT

 

 

 

Flip up the dial handle and rotate the odor dial to adjust Odor Neutralizer Technology intensity or to unlock the dial for cartridge access.

Flip up the handle and rotate the dial clockwise until the two teal arrows are aligned. Pull the handle to remove the dial from the nozzle.

Rotate the cartridge counterclockwise in the dial housing and pull out the cartridge to remove it.

 

 

Insertion/Removal: Rotate the odor dial to align the teal arrows. Remove the dial to access the odor cartridge for removal or replacement.

 

Low: Rotate the dial toward the Low position to decrease the intensity to the lowest level when the vacuum is in use.

 

 

High: Rotate the dial toward the High position for the highest intensity level when the vacuum is in use. This position is the recommended setting for optimal performance.

 

  ODOR NEUTRALIZER TECHNOLOGY TIPS

 

 

Odor Dial Must be Installed for Vacuum to Function Properly

  • Remove odor cartridge from dial if you don’t want the benefits of the odor neutralization technology.

 

Maintenance Required

  • Cleanall filters as recommended under Cleaning
  • Emptythe dust cup before storing your
  • Replace the cartridge as recommended under Odor Cartridge
  • Visit qr.sharkclean.com/odortech to learn more and purchase
  • Ifwet pet messes are cleaned up, thoroughly clean the

 

Fragrance Strength Over Time

  • Theintensity of the Odor Neutralizer Technology’s fragrance may diminish over  It may also have no noticeable fragrance at all. This is natural and does not indicate the technology isn’t working. Follow replacement instructions to ensure continued performance.

 

 

 

 

Remove the new odor cartridge from the sealed packaging. To maintain the life of the cartridge, keep it in the sealed packaging until you are ready to install it.

 

Align the teal arrow on the dial cover with the teal arrow on the nozzle, then reinsert the dial into the nozzle. Rotate the dial counterclockwise until it clicks into an intensity setting to engage. Rotate further to change the intensity setting.

 

 

 

 

Align the yellow arrow on the side of the cartridge with the yellow arrow on the side of the dial cover, then insert the cartridge into the dial. Rotate the cartridge clockwise to lock it in place.

 

Dispose of the old cartridge by dropping it into the trash.

 

  WHOLE-HOME CLEANING

  SETTINGS

  WHOLE-HOME CLEANING

  CLEANING MODES

 

 

 

Select surface setting:

O Power Off I Hard Floor

For hard floors and small area rugs.

II Carpet

For carpets.

The Suction Control Slider located on the handle allows you to adjust the suction depending on the floor type.

MIN: to reduce suction and increase maneuverability on carpets.

MAX: to increase suction on hard floors.

To engage Brushroll, select a surface setting, step on floor nozzle, and tilt handle back firmly.

Step on the pedal on the floor nozzle to lift off the pod.

 

 

  HEADLIGHT INDICATOR LIGHTS

 

 

 

 

 

 

 

 

 

 

The headlights will flash or turn red to indicate issues that need attention.

Solid White Lights: The brushroll is spinning and the unit is working as it should.

Solid Red Lights: There is a jam in the brushroll area. Turn off the vacuum and unplug it, then remove any blockages in the nozzle.

Flashing Red Lights: The motorized floor nozzle is overheating. Turn off the vacuum, unplug it, and remove any blockages. Let the vacuum cool down for at least 60 minutes before restarting. See Troubleshooting section for more information.

Flashing White Lights: The vacuum is operating in an environment that is either too hot or too cold. This vacuum will only function properly in temperatures ranging from 32°F (0°C) to 104°F (40°C). Turn the vacuum off and adjust the room temperature.

Press the Handle Release button and pull up on the handle to detach it from the wand.

 

Attach an optional cleaning accessory to handle or wand.

Press the Wand Release button and pull up on the wand to detach it from the pod.

 

 

 

 

  EMPTYING THE DUST CUP

IMPORTANT: Unplug the power cord before performing any maintenance.

 

Empty the dust cup each time you vacuum and periodically during cleaning, when debris in the dust cup reaches the MAX fill line.

  CLEANING THE FILTERS

 

Regularly rinse and replace the filters to maintain your vacuum’s suction power and to maximize the effectiveness of the Odor Neutralizer Technology.

Rinse filters with cold water only. Allow all filters to air-dry for at least 24 hours before reinstalling them to prevent liquid from being drawn into electronic parts.

IMPORTANT: DO NOT use soap when cleaning the filters.

 

 

 

To remove the Dust Cup, slide up on the release button located on the side of dust cup handle. Tilt dust cup forward, then lift to remove.

To empty debris into the trash, press the lower release button and the bottom of the dust cup will drop open.

RINSE PRE-MOTOR FILTERS EVERY MONTH

Remove the Dust Cup, then lift out Filters.

RINSE HEPA FILTER EVERY YEAR

To remove the HEPA Filter, first pull the tab on the bottom of the filter door, then lift off the door. Press the tab on the side of the HEPA filter and pull out the filter.

To reinstall the door, align the top first, then press in the bottom until it clicks into place.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear debris from the Lint Screen in the dust cup. Lift the upper release tab at the top of the dust cup and open the lid. Gently brush the lint screen to remove debris.

To reinstall, place the bottom of the dust cup onto the pod and then tilt until it clicks into place.

 

  MAINTENANCE CHECKING FOR BLOCKAGES

 

  NOZZLE MAINTENANCE

SELF-CLEANING BRUSHROLL

If any hair is wrapped around the brushroll, continue vacuuming, using Carpet mode on a bare floor surface, a low-pile carpet, or a small area rug. This will allow the self-cleaning brushroll to remove the hair wrap and send it to the dust cup.

If you run over a hard or sharp object or notice a noise change while vacuuming, check for blockages or objects caught in the brushroll.

If some fibers remain wrapped around the brushroll after continued use, clear them from the brushroll.

 

 

 

Detach dust cup from vacuum pod. Empty dust cup and remove debris from lint screen in the top of the dust cup.

Detach wand from pod and handle, and check both ends for blockages.

 

 

 

 

 

Clean off any debris on the brushroll.

 

 

 

 

  CORD MAINTENANCE

 

  1. DO NOT pull or carry vacuum cleaner by thecord or use cord as a
  2. DO NOT unplug by pulling on the Grasp the plug, not the cord.
  3. DONOT close the door on the
  4. DO NOT pull the cord around sharp corners.
  5. DO NOT leave the cord near heated

Detach hose from handle by pressing on the release button at the top of the hose. Detach the hose from the pod, and check openings for blockages.

Detach handle from wand and hose from the vacuum pod, and check openings for blockages.

 

 

 

To minimize the risk of power cord damage, DO NOT run the vacuum over the power cord. If this occurs, immediately shut off power to the vacuum and remove the cord from the brushroll or nozzle.

Detach wand from floor nozzle, tilt nozzle neck back, and check opening for blockages.

 

 

To access the nozzle hose, pinch the release touchpoints on the bottom of the nozzle, then lift the cover and clear any blockages.

 

  AVAILABLE ACCESSORIES

 

A Crevice Tool

This slender tool offers extended reach to A B

access corners, baseboards, tight spaces, and ceilings.

B Upholstery Tool

Picks up hair, dust, and large debris from mattresses, couches, curtains, lampshades, and other delicate upholstered fabrics.

C Pet Multi-Tool

A single convertible tool for cleaning tough

pet messes two ways: use the stiff bristle C D

brush to clean stuck-on debris, or take off the bristles to reveal an upholstery tool perfect for removing stubborn pet hair and large piles of debris.

D Duster Crevice Tool

Two cleaning tools in one. The crevice tool gives you extended reach to clean in tight spaces, while the soft brush is ideal for dusting delicate surfaces.

E Pet Power Brush

The turbine brush loosens and removes E F

pet hair and debris from carpets, and powerfully deep-cleans dander out of upholstery and other surfaces.

F Under-Appliance Wand

Clean under and behind hard-to-move appliances and furniture with this adjustable 36” tool. Flip the extension piece over to clean the underside of appliances.

G Anti-Allergen Dust Brush G H

This brush features nylon fiber bristles specifically designed for removing fine dust and allergen particles from the most delicate surfaces.

H HairPro™ Self-Cleaning Pet Power Brush Tackles pet hair and ground-in dirt from above-floor areas like carpeted stairs and upholstery, while actively removing hair wrap as it cleans.

  TROUBLESHOOTING

 

Power cord caught in brushroll or floor nozzle.

  • Tominimize the risk of power cord damage, DO NOT run the vacuum over the power  If this occurs, immediately shut off power to the vacuum and remove the cord from the brushroll or nozzle.
  • Inspect power cord and plug for any damage before use. DO NOT use vacuum cleaner with a damaged cord or plug. Turn off all controls before plugging in or unplugging the vacuum cleaner.Store your vacuum cleaner with the power cord secured around the two cord

Vacuum is not picking up debris. No suction or light suction.

  • Checkfilters to see if they need  Follow instructions for rinsing and air-drying the filters before reinstalling them in the vacuum.
  • Dustcup may be full; empty dust
  • Checkhandle, hose, hose connections, nozzle, wand, pod, and accessories for  Clear any blockages found.
  • Ifany string, hair, or carpet fibers are wrapped around the PowerFins® brushroll, carefully cut debris with scissors and remove from brushroll. See Nozzle Maintenance section for more

Vacuum lifts area rugs.

  • Makesure Power/Surface switch is set to Hard Floor (setting I).
  • Ensurethe suction control slider on the handle is set to
  • Suctionis  Take care when vacuuming area rugs or rugs with delicately sewn edges.

Brushroll does not spin in carpet cleaning mode.

  • If the headlight indicator light turns red, immediately turn off and unplug the vacuum. Remove pod from floor nozzle and clear any blockages. Reconnect nozzle, plug in vacuum, and turn on
  • Withthe power on, recline the handle, which will automatically turn on the
  • If this problem persists on thick carpets, move the suction control slider to

Vacuum turns off on its own or headlight indicator lights flash red.

If your vacuum overheats, the thermostat will automatically turn off the motor. Perform the following steps to restart:

  1. Turnvacuum off and unplug
  2. Empty dust cup and clean filters. See Emptying the Dust Cup and Cleaning and Replacing theFilters sections for more
  3. Checkfor blockages in hose, wand, floor nozzle, accessories, and inlet
  4. Allowunit to cool for a minimum of 60
  5. Plugin vacuum and turn it

Vacuum is emitting air that smells bad.

  • Dustcup may be full; empty dust  Empty dust cup after each use for optimal Odor

 

I Home & Car Detail Kit

Deep-clean your car like a professional I

detailer, or clean hard-to-reach areas in your home. Micro-sized tools let you clean around delicate objects and access the tightest spaces like car vents and computer keyboards.

J Accessory Bag

This convenient accessory storage bag measures 32 cm x 70 cm and fits the Under- Appliance Wand. Smaller size available at sharkaccessories.com.

Neutralizer Technology performance.

J  Check filters to see if they need cleaning. Follow instructions for rinsing and air-drying the filters before reinstalling them.

  • Checkto make sure odor cartridge is installed in the dial and the dial is installed in the
  • Checkthe Odor Neutralizer Technology dial on the nozzle to see what setting is
  • IfOdor Neutralizer Technology dial is at any setting from Low to High and the cartridge has been installed for 6 months or longer, consider replacing
  • Ifthe odor cartridge is still emitting a scent but you dislike it, consider turning the intensity down, or reinstall the dial in the nozzle without the
  • Ifthe Odor Neutralizer Technology cartridge is not emitting a scent, consider replacing

 

For all other issues, please go to support.sharkclean.com or call Customer Service 1-800-798-7398.

 

    FIVE (5) YEAR LIMITED WARRANTY

The Five (5) Year Limited Warranty applies to purchases made from authorized retailers of SharkNinja Operating LLC. Warranty coverage applies to the original owner and to the original product only and is not transferable.

SharkNinja warrants that the unit shall be free from defects in material and workmanship for a period of five (5) years from the date of purchase when it is used under normal household conditions and maintained according to the requirements outlined in the Owner’s Guide, subject to the following conditions and exclusions:

What is covered by this warranty?

  1. The original unit and/or non-wearable parts deemed defective, in SharkNinja’s sole discretion, will be repaired or replaced up to five (5) years from the original purchase
  2. Inthe event a replacement unit is issued, the warranty coverage ends six (6) months following the receipt date of the replacement unit or the remainder of the existing warranty, whichever is  SharkNinja reserves the right to replace the unit with one of equal or greater value.

What is not covered by this warranty?

  1. Normal wear and tear of wearable parts (such as foam filters, HEPA filters, pads, etc.), which require regularmaintenance and/or replacement to ensure the proper functioning of your unit, are not covered by this  Replacement parts are available for purchase at sharkaccessories.com.
  2. Anyunit that has been tampered with or used for commercial
  3. Damage caused by misuse (e.g., vacuuming up water or other liquids), abuse, negligent handling, failure  to perform required maintenance (e.g., not cleaning the filters, not removing debris from the brushroll),   or damage due to mishandling in
  4. Consequential and incidental
  5. Defects caused by repair persons not authorized by SharkNinja. These defects include damages caused in the process of shipping, altering, or repairing the SharkNinja product (or any of its parts) when the repairis performed by a repair person not authorized by
  6. Products purchased, used, or operated outside North

How to get service

If your appliance fails to operate properly while in use under normal household conditions within the warranty period, visit sharkclean.com/support for product care and maintenance self-help. Our Customer Service Specialists are also available at 1-800-798-7398 to assist with product support and warranty service options, including the possibility of upgrading to our VIP warranty service options for select product categories. So we

REGISTER YOUR PURCHASE

registeryourshark.com Scan QR code using

mobile device

 

 

Scan here or visit qr.sharkclean.com/odortech

for more information

 

 

 

 

 

RECORD THIS INFORMATION

Model              Number:              ���������������������������������������������������������������������������������������������������� Serial Number: ������������������������������������������������������������������������������������������������������

Date     of      Purchase:      �������������������������������������������������������������������������������������������� (Keep receipt)

Store of Purchase: ������������������������������������������������������������������������������������������

 

 

TECHNICAL SPECIFICATIONS

Voltage: 120V~, 60Hz Watts: 960W

Benefits of registering your product and creating an account:

  • Get easier, faster product support and access to warrantyinformation
  • Access troubleshooting and product care instructions
  • Be among the first to know about exclusive productpromotions

 

TIP: You can find the model and serial numbers on the QR code label on the bottom of the back of the vacuum pod.

 

may better assist you, please register your product online at registeryourshark.com and have the product on hand when you call.

SharkNinja will cover the cost for the customer to send in the unit to us for repair or replacement. A fee of

$25.95 (subject to change) will be charged when SharkNinja ships the repaired or replacement unit.

How to initiate a warranty claim

You  must call 1-800-798-7398  to initiate a warranty claim. You  will need the receipt as proof of purchase.  We also ask that you register your product online at registeryourshark.com and have the product on hand when you call, so we may better assist you. A Customer Service Specialist will provide you with return and packing instruction information.

How state law applies

This warranty gives you specific legal rights, and you also may have other rights that vary from state to state. Some states do not permit the exclusion or limitation of incidental or consequential damages, so the above may not apply to you.

ODOR NEUTRALIZER TECHNOLOGY SPECIFICATIONS

  1. ProductName: Odor Neutralizer Technology Cartridge
  2. Manufacturer:Shark Ninja 89 A Street Needham, MA 02494 Weight: 17.6g / 0.62oz
  3. Ingredients: Solid SM composite polymer C17 + fragrance SE 272235

 

  NOTES NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLEASE READ CAREFULLY AND KEEP FOR FUTURE REFERENCE.

This Owner’s Guide is designed to help you get a complete understanding of your new Shark® Lift-Away® ADV Upright Vacuum with PowerFins® HairPro™ and Odor Neutralizer Technology.

 

 

SharkNinja Operating LLC US: Needham, MA 02494

CAN: Ville St-Laurent, QC H4S 1A7

1-800-798-7398

sharkclean.com

Illustrations may differ from actual product. We are constantly striving to improve our products; therefore the specifications contained herein are subject to change without notice.

This product may be covered by one or more U.S. patents. See sharkninja.com/patents for more information.

 

 

© 2023 SharkNinja Operating LLC. LIFT-AWAY, POWERFINS, and SHARK are registered trademarks of SharkNinja Operating LLC. HAIRPRO is a trademark of SharkNinja Operating LLC.

 

LA481Series�IB�MP�Mv8

DOWNLOAD PDF

Shark LA481 Lift-Away ADV Upright Vacuum Owner Guide

REFERENCE LINK

https://www.sharkclean.com/

Leave a Reply